Differences in Pressure Recovery Between Balloon Expandable and Self-expandable Transcatheter Aortic Valves

被引:0
|
作者
Hoda Hatoum
Rebecca T. Hahn
Scott Lilly
Lakshmi Prasad Dasi
机构
[1] The Ohio State University,Department of Biomedical Engineering
[2] Columbia University Medical Center,Division of Cardiology
[3] The Ohio State University,Division of Cardiovascular Medicine
来源
关键词
Transcatheter aortic valve; Pressure recovery; Doppler; Catheterization; Turbulence; Pressure gradient;
D O I
暂无
中图分类号
学科分类号
摘要
Pressure recovery downstream of the aortic valve constitutes an important factor affecting the calculation of pressure gradient (PG) across the valve and therefore the accuracy of the calculated aortic valve area. Some clinical studies hypothesized that stent and valve cusps design contribute to flow acceleration and Doppler-measured valve gradients across the balloon-expandable transcatheter aortic valve. This study aims at elucidating the physical mechanisms behind pressure recovery variations between Edwards SAPIEN 3 and Medtronic Evolut TAVs through the measurements of sensitive and precise axial pressure profiles. A 23 mm Edwards SAPIEN3 and a 26 mm Medtronic Evolut were deployed in a pulse duplicator. A Millar catheter was used to record 50 cycles of pressure data along the centerline of the valve chamber upstream and downstream of the valve. The peak PG obtained with SAPIEN at vena contracta (VC) is 18.83 ± 0.75 mmHg and after recovery, 9.56 ± 0.78 mmHg. For Evolut at VC, peak PG is 18.25 ± 0.63 mmHg and after recovery, 10.3 ± 0.57 mmHg. The differences in peak PG at VC and at the recovery were statistically significant (p < 0.001). With SAPIEN 3 at VC, the mean PG obtained is 10.11 ± 0.63 mmHg and after recovery 7.06 ± 0.46 mmHg. For Evolut, mean PG at VC is 10.45 ± 0.67 mmHg and after recovery 7.99 ± 0.61 mmHg. The differences between the mean PG between the two valves was not statistically significant at VC (p = 0.71) but significant post-recovery (p < 0.00001). While gradients at the VC are higher with the SAPIEN 3, the net gradient after pressure recovery is significantly lower compared to Evolut TAV. Efficiency of pressure recovery significantly depends on valve type due to stent interference with the recovering blood flow.
引用
收藏
页码:860 / 867
页数:7
相关论文
共 50 条
  • [21] Prosthesis-Patient Mismatch After Transcatheter Implantation of Contemporary Balloon-Expandable and Self-Expandable Valves in Small Aortic Annuli
    Leone, Pier Pasquale
    Regazzoli, Damiano
    Cannata, Francesco
    Pagnesi, Matteo
    Barbanti, Marco
    de Cruz, Hospital
    Adamo, Marianna
    Taramasso, Maurizio
    De Marco, Federico
    Mangieri, Antonio
    Giannini, Francesco
    Ohno, Yohei
    Saia, Francesco
    Ielasi, Alfonso
    Pighi, Michele
    Ribichini, Flavio
    Maffeo, Diego
    Stefanini, Giulio
    Bedogni, Francesco
    Kim, Won-Keun
    Maisano, Francesco
    Tamburino, Corrado
    Van Mieghem, Nicolas
    Colombo, Antonio
    Reimers, Bernhard
    Latib, Azeem
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 80 (12) : B203 - B203
  • [22] Evaluation of Acquired Thrombocytopenia According to the Balloon-Expandable Versus Self-Expandable Valves in Patients Undergoing Transcatheter Aortic Valve Replacement
    Kisacik, Halil
    Tok, Derya
    Balci, Kevser Gulcihan
    Demirkan, Burcu
    Karakurt, Mustafa
    Acar, Burak
    Karabulut, Ozlem
    Erbay, Ilke
    Balci, Mustafa Mucahit
    ANGIOLOGY, 2021, 72 (03) : 290 - 294
  • [23] REPLY: Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves CHOICE Trial Results
    Abdel-Wahab, Mohamed
    Richardt, Gert
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (02) : 236 - 237
  • [24] Prosthesis-patient mismatch after transcatheter implantation of contemporary balloon-expandable and self-expandable valves in small aortic annuli
    Leone, Pier Pasquale
    Regazzoli, Damiano
    Pagnesi, Matteo
    Costa, Giuliano
    Teles, Rui
    Adamo, Marianna
    Taramasso, Maurizio
    De Marco, Federico
    Mangieri, Antonio
    Kargoli, Faraj
    Ohno, Yohei
    Saia, Francesco
    Ielasi, Alfonso
    Ribichini, Flavio
    Maffeo, Diego
    Kim, Won-Keun
    Maisano, Francesco
    Van Mieghem, Nicolas M.
    Colombo, Antonio
    Reimers, Bernhard
    Latib, Azeem
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2023, 102 (05) : 931 - 943
  • [25] Meta-Analysis Comparing Transcatheter Aortic Valve Implantation With Balloon Versus Self-Expandable Valves
    Osman, Mohammed
    Ghaffar, Yasir Abdul
    Saleem, Maryam
    Kheiri, Babikir
    Osman, Khansa
    Munir, Muhammad Bilal
    Alkhouli, Mohamad
    AMERICAN JOURNAL OF CARDIOLOGY, 2019, 124 (08): : 1252 - 1256
  • [26] Comparison of balloon-expandable valves versus self-expandable valves in high-risk patients undergoing transcatheter aortic valve replacement for severe aortic stenosis
    Chang, Hsiao-Huang
    Chen, I-Ming
    Chen, Po-Lin
    Hsu, Tsui-Lieh
    Lin, Su-Man
    Chen, Ying-Hwa
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2015, 78 (06) : 331 - 338
  • [27] Pathology of balloon-expandable transcatheter aortic valves
    Yahagi, Kazuyuki
    Ladich, Elena
    Kutys, Robert
    Mori, Hiroyoshi
    Svensson, Lars G.
    Mack, Michael J.
    Herrmann, Howard C.
    Smith, Craig R.
    Leon, Martin B.
    Virmani, Renu
    Finn, Aloke V.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (06) : 1048 - 1057
  • [28] Transcatheter Self-Expandable Aortic Valve Implantation in the Expandable Surgical Aortic Valve
    Hirota, Masataka
    Domoto, Satoru
    Inagaki, Yusuke
    Yoshikawa, Masafumi
    Yamaguchi, Junichi
    Niinami, Hiroshi
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (11) : 1397 - 1399
  • [29] Balloon-Expandable Versus Self-Expandable Valve in Transcatheter Aortic Valve Replacement: A NationWide Study
    Sa, Young Kyoung
    Choi, Ik Jun
    Chang, Kiyuk
    Hwang, Byung-Hee
    Chung, Woo-Baek
    Lee, Kwan Yong
    Choo, Eun-Ho
    Kim, Chan Joon
    Park, Mahn Won
    Choi, Yoon Seok
    Park, Chul Soo
    Yoo, Ki Dong
    Jeon, Doo Soo
    Oak, Min -Ho
    Lee, Jungkuk
    Kang, Dongwoo
    AMERICAN JOURNAL OF CARDIOLOGY, 2024, 213 : 119 - 125
  • [30] Balloon-expandable versus Self-expandable Transcatheter Aortic Valve Prostheses: Comparison of periinterventional Outcomes
    Kuntscher, A.
    Lassnig, E.
    Porodko, M.
    Srndic, E.
    Geissler, H. K.
    Binder, R. K.
    WIENER KLINISCHE WOCHENSCHRIFT, 2023, 135 : S391 - S391