Differences in Pressure Recovery Between Balloon Expandable and Self-expandable Transcatheter Aortic Valves

被引:0
|
作者
Hoda Hatoum
Rebecca T. Hahn
Scott Lilly
Lakshmi Prasad Dasi
机构
[1] The Ohio State University,Department of Biomedical Engineering
[2] Columbia University Medical Center,Division of Cardiology
[3] The Ohio State University,Division of Cardiovascular Medicine
来源
关键词
Transcatheter aortic valve; Pressure recovery; Doppler; Catheterization; Turbulence; Pressure gradient;
D O I
暂无
中图分类号
学科分类号
摘要
Pressure recovery downstream of the aortic valve constitutes an important factor affecting the calculation of pressure gradient (PG) across the valve and therefore the accuracy of the calculated aortic valve area. Some clinical studies hypothesized that stent and valve cusps design contribute to flow acceleration and Doppler-measured valve gradients across the balloon-expandable transcatheter aortic valve. This study aims at elucidating the physical mechanisms behind pressure recovery variations between Edwards SAPIEN 3 and Medtronic Evolut TAVs through the measurements of sensitive and precise axial pressure profiles. A 23 mm Edwards SAPIEN3 and a 26 mm Medtronic Evolut were deployed in a pulse duplicator. A Millar catheter was used to record 50 cycles of pressure data along the centerline of the valve chamber upstream and downstream of the valve. The peak PG obtained with SAPIEN at vena contracta (VC) is 18.83 ± 0.75 mmHg and after recovery, 9.56 ± 0.78 mmHg. For Evolut at VC, peak PG is 18.25 ± 0.63 mmHg and after recovery, 10.3 ± 0.57 mmHg. The differences in peak PG at VC and at the recovery were statistically significant (p < 0.001). With SAPIEN 3 at VC, the mean PG obtained is 10.11 ± 0.63 mmHg and after recovery 7.06 ± 0.46 mmHg. For Evolut, mean PG at VC is 10.45 ± 0.67 mmHg and after recovery 7.99 ± 0.61 mmHg. The differences between the mean PG between the two valves was not statistically significant at VC (p = 0.71) but significant post-recovery (p < 0.00001). While gradients at the VC are higher with the SAPIEN 3, the net gradient after pressure recovery is significantly lower compared to Evolut TAV. Efficiency of pressure recovery significantly depends on valve type due to stent interference with the recovering blood flow.
引用
收藏
页码:860 / 867
页数:7
相关论文
共 50 条
  • [1] Differences in Pressure Recovery Between Balloon Expandable and Self-expandable Transcatheter Aortic Valves
    Hatoum, Hoda
    Hahn, Rebecca T.
    Lilly, Scott
    Dasi, Lakshmi Prasad
    ANNALS OF BIOMEDICAL ENGINEERING, 2020, 48 (02) : 860 - 867
  • [2] A Novel Transcarotid Approach for Implantation of Balloon-Expandable or Self-Expandable Transcatheter Aortic Valves
    Campelo-Parada, Francisco
    Rodes-Cabau, Josep
    Dumont, Eric
    Del Trigo, Maria
    Regueiro, Ander
    Doyle, Daniel
    De Larochelliere, Robert
    Paradis, Jean-Michel
    Kalavrouziotis, Dimitri
    Mohammadi, Siamak
    CANADIAN JOURNAL OF CARDIOLOGY, 2016, 32 (12) : 1575.e9 - 1575.e12
  • [3] Balloon-Expandable or Self-Expandable Valves in Valve-in-Valve Transcatheter Aortic Valve Implantation?
    Van Nieuwkerk, Astrid
    Fernandez-Nofrerias, Eduard
    Tchetche, Didier
    Brito, Fabio, Jr.
    Barbanti, Marco
    Kornowski, Ran
    Latib, Azeem
    d'Onofrio, Augusto
    Ribichini, Flavio
    Tello, Vicente Mainar
    Dumonteil, Nicolas
    Baan, Jan
    Abizaid, Alexandre
    Sartori, Samantha
    d'Errigo, Paola
    Tarantini, Giuseppe
    Lunardi, Mattia
    Orvin, Katia
    Pagnesi, Matteo
    Ghattas, Angie
    Dangas, George
    Mehran, Roxana
    Delewi, Ronak
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 78 (19) : B66 - B66
  • [4] Comparative Meta-Analysis of Balloon Expandable and Self-Expandable Valves for Transcatheter Aortic Valve Replacement
    Agarwal, Shikhar
    Parashar, Akhil
    Svensson, Lars G.
    Krishnaswamy, Amar
    Tuzcu, E. M.
    Kapadia, Samir R.
    CIRCULATION, 2014, 130
  • [5] Combination Use of Inoue-Balloon and Self-Expandable Transcatheter Valves in Managing Aortic Stenosis Not Amenable to Balloon-Expandable Valves
    Saji, Mike
    Highchi, Ryosuke
    Iguchi, Nobuo
    Takamisawa, Itaru
    Shimizu, Jun
    Shimokawa, Tomoki
    Nanasato, Mamoru
    Takayama, Morimasa
    Isobe, Mitsuaki
    INTERNATIONAL HEART JOURNAL, 2022, 63 (05) : 843 - 851
  • [6] Asian Comparative Outcomes of Balloon-Expandable versus Self-expandable valves for Transcatheter Aortic Valve Implantation
    Yoon, Sung-Han
    Ahn, Jung-Min
    Lee, Michael Kang-Yin
    Tay, Edgar L.
    Kim, Young-Hak
    Lee, Cheol Whan
    Lee, Jong-Young
    Yang, Dong Hyun
    Kang, Joon-Won
    Choi, Hyo In
    Roh, Jae Hyung
    Lee, Pil Hyung
    Chang, Mineok
    Park, Hyun Woo
    Kang, Soo-Jin
    Park, Duk-Woo
    Lee, Seung-Whan
    Song, Jong-Min
    Park, Seong-Wook
    Park, Seung-Jung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B220 - B220
  • [7] Comparative meta-analysis of balloon-expandable and self-expandable valves for transcatheter aortic valve replacement
    Agarwal, Shikhar
    Parashar, Akhil
    Kumbhani, Dharam J.
    Svensson, Lars G.
    Krishnaswamy, Amar
    Tuzcu, E. Murat
    Kapadia, Samir R.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 197 : 87 - 97
  • [8] BALLOON-EXPANDABLE VERSUS SELF-EXPANDABLE TRANSCATHETER AORTIC VALVE REPLACEMENT
    Okumura, L.
    Sanchez, L.
    Alves, M.
    Candolfi, P.
    VALUE IN HEALTH, 2021, 24 : S68 - S68
  • [9] Comparison of Outcomes of Balloon-Expandable Versus Self-Expandable Transcatheter Heart Valves for Severe Aortic Stenosis
    Wijeysundera, Harindra C.
    Qiu, Feng
    Koh, Maria
    Prasad, Treesa J.
    Cantor, Warren J.
    Cheema, Asim
    Chu, Michael W. A.
    Czarnecki, Andrew
    Feindel, Christopher
    Fremes, Stephen E.
    Kingsbury, Kori J.
    Natarajan, Madhu K.
    Peterson, Mark
    Ruel, Marc
    Strauss, Bradley
    Ko, Dennis T.
    AMERICAN JOURNAL OF CARDIOLOGY, 2017, 119 (07): : 1094 - 1099
  • [10] Balloon-expandable or self-expandable transcatheter heart valves. Which are best?
    Webb, John
    Wood, David
    Sathananthan, Janarthanan
    Landes, Uri
    EUROPEAN HEART JOURNAL, 2020, 41 (20) : 1900 - 1902