Accuracy of CT-based patient-specific guides for total knee arthroplasty in patients with post-traumatic osteoarthritis

被引:6
|
作者
Schotanus M.G.M. [1 ]
van Haaren E.H. [2 ]
Hendrickx R.P.M. [2 ]
Jansen E.J.P. [2 ]
Kort N.P. [2 ]
机构
[1] Medical Researcher at Zuyderland Medical Centre, Dr H vd Hoffplein 1, Sittard-Geleen
[2] Orthopedic Surgeon at Zuyderland Medical Centre, Sittard-Geleen
关键词
CT-based; Knee alignment; Patient-specific guides; Post-traumatic osteoarthritis; Retained metal hardware; Total knee arthroplasty;
D O I
10.1007/s00590-015-1677-3
中图分类号
学科分类号
摘要
Published clinical trials who studied the accuracy of patient-specific guides (PSG) for total knee arthroplasty exclude patients with articular deformity of the knee joint. We prospectively analysed a series of 30 patients with post-traumatic osteoarthritis of the knee joint with use of PSG. At 1 year post-operative, the achieved biomechanical (HKA) axis and varus/valgus of the femur and tibia components were measured on anterior–posterior (AP) long-standing weight-bearing radiographs. Flexion/extension of the femoral and AP slope of the tibia component was measured on standard lateral radiographs. Percentages >3° deviation of the pre-operative planned HKA axis and individual implant components were considered as outliers. Approved and used implant size, median blood loss (ml) and operation time (min) were obtained from the operation records. Pre- and 1-year post-operative patient-reported outcome measures (PROMs) were performed. Eighty-three per cent of the patients had a HKA axis restored <3° of the pre-operative planned alignment. Varus/valgus outliers were 0.0 and 6.7 % for the femoral and tibial components, respectively. Percentages of outliers of flexion/extension were 36.7 % for the femoral component and 10.0 % for the AP slope of the tibial component. Median blood loss was 300 ml (50–700), while operation time was 67 min (44–144). In 20 % of all cases, the approved implant size was changed into one size smaller. One-year post-operative PROMs improved significantly. We conclude that the accuracy of CT-based PSG is not impaired in patients with post-traumatic osteoarthritis and this modality can restore biomechanical limb alignment. © 2015, Springer-Verlag France.
引用
收藏
页码:1313 / 1320
页数:7
相关论文
共 50 条
  • [21] Functional Outcomes and Accuracy of Patient-Specific Instruments for Total Knee Arthroplasty
    Stone, Andrea H.
    Sibia, Udai S.
    MacDonald, James H.
    [J]. SURGICAL INNOVATION, 2018, 25 (05) : 470 - 475
  • [22] Total knee arthroplasty for post-traumatic arthrosis
    Lonner, JH
    Pedlow, FX
    Siliski, JM
    [J]. JOURNAL OF ARTHROPLASTY, 1999, 14 (08): : 969 - 975
  • [23] Patient-Specific Instrumentation Does Not Improve Accuracy in Total Knee Arthroplasty
    Shen, Chong
    Tang, Zhi-Hong
    Hu, Jun-Zu
    Zou, Guo-Yao
    Xiao, Rong-Chi
    Yan, Dong-Xue
    [J]. ORTHOPEDICS, 2015, 38 (03) : E178 - E188
  • [24] MRI-based or CT-based patient-specific instrumentation in Total knee Arthroplasty: How do the two systems compare?
    Dong-Geun Kang
    Kang-Il Kim
    Jung-Kwon Bae
    [J]. Arthroplasty, 2
  • [25] MRI-based or CT-based patient-specific instrumentation in Total knee Arthroplasty: How do the two systems compare?
    Kang, Dong-Geun
    Kim, Kang-Il
    Bae, Jung-Kwon
    [J]. ARTHROPLASTY, 2020, 2 (01)
  • [26] Operative efficiency and accuracy of patient-specific cutting guides in total knee replacement
    Nankivell, Mark
    West, Graeme
    Pourgiezis, Nicholas
    [J]. ANZ JOURNAL OF SURGERY, 2015, 85 (06) : 452 - 455
  • [27] Robotic total knee arthroplasty - The accuracy of CT-based component placement
    Decking, J
    Theis, C
    Achenbach, T
    Roth, E
    Nafe, B
    Eckardt, A
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (05): : 573 - 579
  • [28] Corrective osteotomies of phalangeal and metacarpal malunions using patient-specific guides: CT-based accuracy evaluation
    Hirsiger, Stefanie
    Miyake, Junichi
    Furnstahl, Philipp
    Nagy, Ladislav
    Schweizer, Andreas
    [J]. SWISS MEDICAL WEEKLY, 2015, 145 : 21S - 21S
  • [29] Early clinical and radiological results of total knee arthroplasty using patient-specific guides in obese patients
    Anwar, Rahij
    Kini, Sunil Gurpur
    Sait, Saif
    Bruce, Warwick J. M.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (02) : 265 - 270
  • [30] Early clinical and radiological results of total knee arthroplasty using patient-specific guides in obese patients
    Rahij Anwar
    Sunil Gurpur Kini
    Saif Sait
    Warwick J. M. Bruce
    [J]. Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 265 - 270