Development of NTD-Ge Cryogenic Sensors in LUMINEU

被引:0
|
作者
Xavier-Francois Navick
Cyril Bachelet
David Bouville
Noel Coron
Laurent Devoyon
Andrea Giuliani
David Gray
Serge Hervé
Vincent Humbert
Mathieu Lemaitre
Martin Loidl
Pierre de Marcillac
Claudia Nones
Yves Pénichot
Thierry Redon
Alexis René
Matias Rodrigues
机构
[1] CEA,
[2] DSM/IRFU,undefined
[3] CSNSM,undefined
[4] CNRS & Univ. Orsay,undefined
[5] IEF,undefined
[6] CNRS & Univ. Orsay,undefined
[7] IAS,undefined
[8] CNRS & Univ. Orsay,undefined
[9] CEA,undefined
[10] DEN/DANS/Orphée,undefined
[11] CEA,undefined
[12] DRT/LIST/LNHB,undefined
来源
关键词
Thermal sensor; Cryogenics; Dark Matter; Double beta decay;
D O I
暂无
中图分类号
学科分类号
摘要
One of the goals of LUMINEU is to develop NTD-Ge sensors for various applications. The steps are to produce NTD-Ge sensors first, then to study the dependence of their performance on the production parameters, and finally to optimize their electric contacts. In this paper, we present the different possibilities for estimating and measuring the real neutron fluence received by each Ge wafer irradiated in a thermal neutron reactor. Measurements of their resistivity at 300 K indicate a fluence discrepancy from the expected value and confirm the homogeneity of the doping throughout the volume. In addition, we present a method allowing an improved estimation of the impedance below 30 mK just by measuring the ratio of the NTDs’ resistivity at 77 and 4 K.
引用
收藏
页码:292 / 298
页数:6
相关论文
共 50 条
  • [31] Cryogenic temperature sensors
    Kar, S.
    Sharma, R. G.
    DEFENCE SCIENCE JOURNAL, 2007, 57 (03) : 195 - 208
  • [32] CRYOGENIC TEMPERATURE SENSORS
    SWARTZ, JM
    SWARTZ, DL
    INSTRUMENTATION TECHNOLOGY, 1974, 21 (01): : 33 - 38
  • [33] Cryogenic temperature sensors
    Niculescu, D.
    Cruceanu, E.
    Metrologia aplicata, 1988, 35 (01): : 34 - 37
  • [34] SENSORS FOR CRYOGENIC THERMOMETRY
    PIERCE, WG
    BARTOS, DJ
    INSTRUMENTATION TECHNOLOGY, 1983, 30 (07): : 53 - 56
  • [35] CALIBRATING CRYOGENIC SENSORS
    STONE, OC
    SCHNEIDER, DB
    INSTRUMENTATION TECHNOLOGY, 1967, 14 (04): : 53 - +
  • [36] A pathway for skin NTD diagnostic development
    Marks, Michael
    Vedithi, Sundeep Chaitanya
    van de Sande, Wendy W. J.
    Levecke, Bruno
    Solomon, Anthony W.
    Asiedu, Kingsley
    Ducker, Camilla L.
    Lammie, Patrick
    Dagne, Daniel Argaw
    Cruz, Isra
    PLOS NEGLECTED TROPICAL DISEASES, 2024, 18 (11):
  • [37] Ge films on GaAs: Low-temperature electrical properties and application to cryogenic resistance temperature sensors
    Mitin, VF
    Tkhorik, YA
    Venger, EF
    CZECHOSLOVAK JOURNAL OF PHYSICS, 1996, 46 : 2855 - 2856
  • [38] Low temperature properties of NTD Ge: Best choice for cuore experiment
    Pasca, E
    Olivieri, E
    Ventura, G
    Barucci, M
    Risegari, L
    Beeman, J
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS , DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2004, 2 : 93 - 97
  • [39] CALOS: An experiment to study the solar corona with an array of NTD Ge microcalorimeters
    Barbera, M
    Peres, G
    Orlando, S
    Reale, F
    Collura, A
    Serio, S
    Silver, E
    Bandler, S
    Schnopper, HW
    Costa, E
    Bellazzini, R
    LOW TEMPERATURE DETECTORS, 2002, 605 : 547 - 550
  • [40] Electrical characteristics of heavily doped NTD Ge at very low temperatures
    Barucci, M
    Beeman, J
    Olivieri, E
    Pasca, E
    Risegari, L
    Ventura, G