Quantitative analysis of major and minor elements in lead-free solder chip by LA-ICP-MS

被引:5
|
作者
Ido K. [1 ,2 ]
Obayashi H. [3 ,4 ]
Zhu Y. [1 ]
Hirata T. [3 ]
Hokura A. [2 ]
Nonose N. [1 ]
Inagaki K. [1 ,2 ]
机构
[1] National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki
[2] Graduate School of Engineering, Tokyo Denki University, 5 Senju Asahi-cho, Adachi, Tokyo
[3] Geochemical Research Center, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo
[4] Laboratory for Planetary Sciences, Kyoto University, Kitashirakawa Oiwakecho, Sakyo, Kyoto
基金
日本学术振兴会;
关键词
Fractionation; LA-ICP-MS; Matrix match; Quantitative analysis; Solder;
D O I
10.2116/analsci.18SBP07
中图分类号
学科分类号
摘要
A method was established for the quantitative analysis of the elements (Cu, Ag, Pb, and Sn) in solder samples by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), with Sn-based matrix matched standard solutions for defining the calibration curves. It was found that chloride-ion presented in commercially available Sn standard solution resulted in a precipitation of AgCl and caused the deterioration of the linearity of the calibration curve for Ag. Therefore, a laboratory-made chloride-free Sn solution was used to prepare Sn matrix matched standard solutions so as to ensure the stability of the elements including Ag. For the quantitative analysis of solder samples by LA-ICP-MS, the operating conditions of the LA instruments were set to obtain a fluence of over 12 J cm -2 . This is mainly because of larger LA-induced elemental fractionations using a fluence of < 10 J cm -2 . The results for Ag, Cu, Pb, and Sn in a certified reference material (NMIJ CRM 8203-a) were close to, or in agreement with, the certified values, indicating that the present method was valid for the quantitative analysis of the elements in solder samples. In comparison to the certified values, relatively larger uncertainties were obtained for the analytical results by LA-ICP-MS, which could be attributed to the dependence on the homogeneity of the sample because the sample aliquots used for analysis were much smaller than those required for the traditional analytical procedures (i.e., sample quantity ratio of ca. 1:13000). Further improvement of the uncertainty might be obtained by using a larger sample quantity for the analysis by LA-ICP-MS so as to improve the representativeness of the sample. © The Japan Society for Analytical Chemistry.
引用
收藏
页码:693 / 699
页数:6
相关论文
共 50 条
  • [31] Characterization and imaging of lead distribution in bones of lead-exposed birds by ICP-MS and LA-ICP-MS
    Ishii, Chihiro
    Nakayama, Shouta M. M.
    Kataba, Andrew
    Ikenaka, Yoshinori
    Saito, Keisuke
    Watanabe, Yukiko
    Makino, Yoshiki
    Matsukawa, Takehisa
    Kubota, Ayano
    Yokoyama, Kazuhito
    Mizukawa, Hazuki
    Hirata, Takafumi
    Ishizuka, Mayumi
    CHEMOSPHERE, 2018, 212 : 994 - 1001
  • [32] Reliability evaluations of chip interconnect in lead-free solder systems
    Guo, YF
    Lin, JK
    De Silva, A
    52ND ELECTRONIC COMPONENTS & TECHNOLOGY CONFERENCE, 2002 PROCEEDINGS, 2002, : 1275 - 1280
  • [33] LA-ICP-MS analysis of platinum-group elements and other elements of interest in ancient gold
    L. Dussubieux
    L. van Zelst
    Applied Physics A, 2004, 79 : 353 - 356
  • [34] LA-ICP-MS analysis of platinum-group elements and other elements of interest in ancient gold
    Dussubieux, L
    Van Zelst, L
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2004, 79 (02): : 353 - 356
  • [35] Development and evaluation of a standard method for the quantitative determination of elements in float glass samples by LA-ICP-MS
    Latkoczy, C
    Becker, S
    Dücking, M
    Günther, D
    Hoogewerff, JA
    Almirall, JR
    Buscaglia, J
    Dobney, A
    Koons, RD
    Montero, S
    van der Peijl, GJQ
    Stoecklein, WRS
    Trejos, T
    Watling, JR
    Zdanowicz, VS
    JOURNAL OF FORENSIC SCIENCES, 2005, 50 (06) : 1327 - 1341
  • [36] LA-ICP-MS analysis of waste polymer materials
    Stehrer, T.
    Heitz, J.
    Pedarnig, J. D.
    Huber, N.
    Aeschlimann, B.
    Guenther, D.
    Scherndl, H.
    Linsmeyer, T.
    Wolfmeir, H.
    Arenholz, E.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (01) : 415 - 424
  • [37] Trace element analysis of wolframite by LA-ICP-MS
    Goldmann, Simon
    Gaebler, Hans-Eike
    Melcher, Frank
    MINERAL DEPOSIT RESEARCH FOR A HIGH-TECH WORLD, VOLS. 1-4, 2013, : 194 - 196
  • [38] Current approaches to calibration of LA-ICP-MS analysis
    Miliszkiewicz, Natalia
    Walas, Stanislaw
    Tobiasz, Anna
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (02) : 327 - 338
  • [39] Current approaches to calibration of LA-ICP-MS analysis
    Walas, Stanis&lstrok;aw (walas@chemia.uj.edu.pl), 1600, Royal Society of Chemistry (30):
  • [40] Single-Cell Analysis by LA-ICP-MS
    Hutchinson, Robert W.
    Hutchinson, James A.
    TRANSPLANTATION, 2015, 99 (11) : 2237 - 2238