Quantitative analysis of major and minor elements in lead-free solder chip by LA-ICP-MS

被引:5
|
作者
Ido K. [1 ,2 ]
Obayashi H. [3 ,4 ]
Zhu Y. [1 ]
Hirata T. [3 ]
Hokura A. [2 ]
Nonose N. [1 ]
Inagaki K. [1 ,2 ]
机构
[1] National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki
[2] Graduate School of Engineering, Tokyo Denki University, 5 Senju Asahi-cho, Adachi, Tokyo
[3] Geochemical Research Center, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo
[4] Laboratory for Planetary Sciences, Kyoto University, Kitashirakawa Oiwakecho, Sakyo, Kyoto
基金
日本学术振兴会;
关键词
Fractionation; LA-ICP-MS; Matrix match; Quantitative analysis; Solder;
D O I
10.2116/analsci.18SBP07
中图分类号
学科分类号
摘要
A method was established for the quantitative analysis of the elements (Cu, Ag, Pb, and Sn) in solder samples by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), with Sn-based matrix matched standard solutions for defining the calibration curves. It was found that chloride-ion presented in commercially available Sn standard solution resulted in a precipitation of AgCl and caused the deterioration of the linearity of the calibration curve for Ag. Therefore, a laboratory-made chloride-free Sn solution was used to prepare Sn matrix matched standard solutions so as to ensure the stability of the elements including Ag. For the quantitative analysis of solder samples by LA-ICP-MS, the operating conditions of the LA instruments were set to obtain a fluence of over 12 J cm -2 . This is mainly because of larger LA-induced elemental fractionations using a fluence of < 10 J cm -2 . The results for Ag, Cu, Pb, and Sn in a certified reference material (NMIJ CRM 8203-a) were close to, or in agreement with, the certified values, indicating that the present method was valid for the quantitative analysis of the elements in solder samples. In comparison to the certified values, relatively larger uncertainties were obtained for the analytical results by LA-ICP-MS, which could be attributed to the dependence on the homogeneity of the sample because the sample aliquots used for analysis were much smaller than those required for the traditional analytical procedures (i.e., sample quantity ratio of ca. 1:13000). Further improvement of the uncertainty might be obtained by using a larger sample quantity for the analysis by LA-ICP-MS so as to improve the representativeness of the sample. © The Japan Society for Analytical Chemistry.
引用
收藏
页码:693 / 699
页数:6
相关论文
共 50 条
  • [11] Rare earth elements analysis of geological samples by LA-ICP-MS
    Luo, Y.
    Liu, Y.
    Hu, S.
    Gao, S.
    Diqiu Kexue Zhongguo Dizhi Daxue Xuebao/Earth Science - Journal of China University of Geosciences, 2001, 26 (05): : 508 - 512
  • [12] Comparison of LA-ICP-MS and LA-ICP-OES for the analysis of some elements in fly ashes
    Stankova, Alice
    Gilon, Nicole
    Dutruch, Lionel
    Kanicky, Viktor
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (02) : 443 - 449
  • [13] Quantitative analysis of silicates using LA-ICP-MS with liquid calibration
    Halicz, L
    Günther, D
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (12) : 1539 - 1545
  • [14] Failure analysis of lead-free solder joints for flip chip on board
    Tzu, Fu-Ming
    Chao, Long-Sun
    Chou, Jung-Hua
    2007 INTERNATIONAL MICROSYSTEMS, PACKAGING, ASSEMBLY AND CIRCUITS TECHNOLOGY CONFERENCE, PROCEEDINGS OF TECHNICAL PAPERS, 2007, : 314 - 317
  • [15] A Flux-Free Fusion Technique for Rapid Determination of Major and Trace Elements in Silicate Rocks by LA-ICP-MS
    He, Zhiwei
    Huang, Fang
    Yu, Huimin
    Xiao, Yilin
    Wang, Fangyue
    Li, Qiuli
    Xia, Ying
    Zhang, Xingchao
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2016, 40 (01) : 5 - 27
  • [16] In situ analysis of major and trace elements of anhydrous minerals by LA-ICP-MS without applying an internal standard
    Liu, Yongsheng
    Hu, Zhaochu
    Gao, Shan
    Guenther, Detlef
    Xu, Jaun
    Gao, Changgui
    Chen, Haihong
    CHEMICAL GEOLOGY, 2008, 257 (1-2) : 34 - 43
  • [17] Comparison between LA-ICP-MS and EPMA analysis of trace elements in diamonds
    Weiss, Y.
    Griffin, W. L.
    Elhlou, S.
    Navon, O.
    CHEMICAL GEOLOGY, 2008, 252 (3-4) : 158 - 168
  • [18] Quantitative analysis of the elements in powder samples by LA-ICP-MS with PMMA powder as the binder and Cs as the internal standard
    Zhu, Yanbei
    Hioki, Akiharu
    Chiba, Koichi
    Journal of Analytical Atomic Spectrometry, 2013, 28 (02): : 301 - 306
  • [19] Application of laser ablation inductively coupled mass spectrometry (LA-ICP-MS) for the determination of major, minor, and trace elements in bark samples
    U. Narewski
    G. Werner
    H. Schulz
    C. Vogt
    Fresenius' Journal of Analytical Chemistry, 2000, 366 : 167 - 170
  • [20] Application of laser ablation inductively coupled mass spectrometry (LA-ICP-MS) for the determination of major, minor, and trace elements in bark samples
    Narewski, U
    Werner, G
    Schulz, H
    Vogt, C
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (02): : 167 - 170