Quantitative analysis of major and minor elements in lead-free solder chip by LA-ICP-MS

被引:5
|
作者
Ido K. [1 ,2 ]
Obayashi H. [3 ,4 ]
Zhu Y. [1 ]
Hirata T. [3 ]
Hokura A. [2 ]
Nonose N. [1 ]
Inagaki K. [1 ,2 ]
机构
[1] National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki
[2] Graduate School of Engineering, Tokyo Denki University, 5 Senju Asahi-cho, Adachi, Tokyo
[3] Geochemical Research Center, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo
[4] Laboratory for Planetary Sciences, Kyoto University, Kitashirakawa Oiwakecho, Sakyo, Kyoto
基金
日本学术振兴会;
关键词
Fractionation; LA-ICP-MS; Matrix match; Quantitative analysis; Solder;
D O I
10.2116/analsci.18SBP07
中图分类号
学科分类号
摘要
A method was established for the quantitative analysis of the elements (Cu, Ag, Pb, and Sn) in solder samples by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), with Sn-based matrix matched standard solutions for defining the calibration curves. It was found that chloride-ion presented in commercially available Sn standard solution resulted in a precipitation of AgCl and caused the deterioration of the linearity of the calibration curve for Ag. Therefore, a laboratory-made chloride-free Sn solution was used to prepare Sn matrix matched standard solutions so as to ensure the stability of the elements including Ag. For the quantitative analysis of solder samples by LA-ICP-MS, the operating conditions of the LA instruments were set to obtain a fluence of over 12 J cm -2 . This is mainly because of larger LA-induced elemental fractionations using a fluence of < 10 J cm -2 . The results for Ag, Cu, Pb, and Sn in a certified reference material (NMIJ CRM 8203-a) were close to, or in agreement with, the certified values, indicating that the present method was valid for the quantitative analysis of the elements in solder samples. In comparison to the certified values, relatively larger uncertainties were obtained for the analytical results by LA-ICP-MS, which could be attributed to the dependence on the homogeneity of the sample because the sample aliquots used for analysis were much smaller than those required for the traditional analytical procedures (i.e., sample quantity ratio of ca. 1:13000). Further improvement of the uncertainty might be obtained by using a larger sample quantity for the analysis by LA-ICP-MS so as to improve the representativeness of the sample. © The Japan Society for Analytical Chemistry.
引用
收藏
页码:693 / 699
页数:6
相关论文
共 50 条
  • [1] Quantitative Analysis of Major and Minor Elements in Lead-free Solder Chip by LA-ICP-MS
    Ido, Koyo
    Obayashi, Hideyuki
    Zhu, Yanbei
    Hirata, Takafumi
    Hokura, Akiko
    Nonose, Naoko
    Inagaki, Kazumi
    ANALYTICAL SCIENCES, 2018, 34 (06) : 693 - 699
  • [2] QUANTITATIVE LA-ICP-MS ANALYSIS OF MAJOR ELEMENTS IN LITHIUM TETRABORATE FUSED SILICATE ROCK BEADS
    Ganev, Valentin
    COMPTES RENDUS DE L ACADEMIE BULGARE DES SCIENCES, 2013, 66 (11): : 1595 - 1602
  • [3] Quantitative analysis of plant leaf elements using the LA-ICP-MS technique
    Diniz, Adriana Pedrosa
    Kozovits, Alessandra Rodrigues
    Lana, Cristiano de Carvalho
    de Abreu, Adriana Tropia
    Praca Leite, Mariangela Garcia
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2019, 435 : 251 - 258
  • [4] Trace and minor elements in galena: A reconnaissance LA-ICP-MS study
    George, Luke
    Cook, Nigel J.
    Ciobanu, Cristiana L.
    Wade, Benjamin P.
    AMERICAN MINERALOGIST, 2015, 100 (2-3) : 548 - 569
  • [5] Combined LA-ICP-MS and cryo-SEM-EDS: An improved technique for quantitative analysis of major, minor, and trace elements in fluid inclusions in halite
    Weldeghebriel, Mebrahtu F.
    Lowenstein, Tim K.
    Garcia-Veigas, Javier
    Collins, David
    Sendula, Eszter
    Bodnar, Robert J.
    Graney, Joseph R.
    Cendon, Dioni, I
    Lensky, Nadav G.
    Mor, Ziv
    Sirota, Ido
    CHEMICAL GEOLOGY, 2020, 551 (551)
  • [6] Quantitative bioimaging of trace elements in the human lens by LA-ICP-MS
    Konz, Ioana
    Fernandez, Beatriz
    Luisa Fernandez, M.
    Pereiro, Rosario
    Gonzalez-Iglesias, Hector
    Coca-Prados, Miguel
    Sanz-Medel, Alfredo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (9-10) : 2343 - 2348
  • [7] Quantitative mapping of trace elements in agate using LA-ICP-MS
    Park C.-S.
    Shin H.S.
    Yi K.
    Cho H.
    Kim Y.
    Journal of Analytical Science and Technology, 6 (1)
  • [8] Quantitative bioimaging of trace elements in the human lens by LA-ICP-MS
    Ioana Konz
    Beatriz Fernández
    M. Luisa Fernández
    Rosario Pereiro
    Héctor González-Iglesias
    Miguel Coca-Prados
    Alfredo Sanz-Medel
    Analytical and Bioanalytical Chemistry, 2014, 406 : 2343 - 2348
  • [9] Quantitative analysis of elements migration in human teeth with and without filling using LA-ICP-MS
    Hanc, Anetta
    Olszewska, Aneta
    Baralkiewicz, Danuta
    MICROCHEMICAL JOURNAL, 2013, 110 : 61 - 69
  • [10] Reliability analysis of lead-free flip chip solder joint
    Wang, Dong
    Ma, Xiaosong
    Guo, Dan
    ICEPT: 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONICS PACKAGING TECHNOLOGY, PROCEEDINGS, 2007, : 787 - 791