Improved energy resolution of highly segmented HPGe detectors by noise reduction

被引:0
|
作者
A. Wiens
B. Birkenbach
B. Bruyneel
J. Eberth
H. Hess
Gh. Pascovici
P. Reiter
D. Bazzacco
E. Farnea
C. Michelagnoli
F. Recchia
机构
[1] Institut für Kernpyhsik,Nuclear Science Division
[2] INFN,undefined
[3] Sezione di Padova,undefined
[4] Lawrence Berkeley National Laboratory,undefined
[5] CEA Saclay - IRFU,undefined
来源
关键词
Energy Resolution; HPGe Detector; Noise Contribution; Electronic Noise; Fano Factor;
D O I
暂无
中图分类号
学科分类号
摘要
Built-in redundancies in highly segmented high-purity Ge detectors are exploited to increase the energy resolution of these semiconductor devices for detection of electromagnetic radiation in the X-ray and γ-ray regime. The information of the two electronically decoupled independent measurements, the cathode and the anode electrodes, provides an improved signal-to-noise ratio through a combination of the individually measured signals performed on an event-by-event basis. The average energy resolution values of the AGATA triple cluster detector for an energy deposition of 60keV was measured to be 1.1 keV (FWHM) for the 36 segments and 1.2 keV for the core. The averaged signals of the core and the segments show an improved resolution value of 0.87 keV which is close to the expected theoretical limit. At higher γ-ray energy the averaging technique allows for an enhanced energy resolution with a FWHM of 2.15keV at 1.3MeV. By means of the position sensitive operation of AGATA a new value for the Fano factor was determined and the noise contributions to the FWHM of a γ-ray peak separated.
引用
收藏
相关论文
共 50 条
  • [31] Application of a Simple PSA Algorithm for HPGe Segmented Detectors to in-Beam Data
    Crespi, F. C. L.
    Bracco, A.
    Camera, F.
    Million, B.
    Vandone, V.
    Wieland, O.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1764 - +
  • [32] Spatial localization of multiple simultaneous hits in segmented HPGe detectors: a new algorithm
    Gatti, E
    Geraci, A
    Casati, G
    Riboldi, S
    Ripamonti, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (03): : 738 - 744
  • [33] Experimental determination of reference pulses for highly segmented HPGe detectors and application to Pulse Shape Analysis used in γ-ray tracking arrays
    Li, H. J.
    Ljungvall, J.
    Michelagnoli, C.
    Clement, E.
    Dudouet, J.
    Desesquelles, P.
    Lopez-Martens, A.
    de France, G.
    EUROPEAN PHYSICAL JOURNAL A, 2018, 54 (11):
  • [34] A low noise and wide dynamic range preamplifier for HPGe detectors
    Hao, Jiajun
    Cheng, Zhengxi
    Ye, Xiangke
    He, Li
    Deng, Zhi
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2024, 8 (03) : 1413 - 1421
  • [35] Response of AGATA Segmented HPGe Detectors to Gamma-Rays up to 15.1 MeV
    Crespi, F. C. L.
    Avigo, R.
    Camera, F.
    Benzoni, G.
    Blasi, N.
    Bottoni, S.
    Bracco, A.
    Brambilla, S.
    Casati, P.
    Coniglio, F.
    Corsi, A.
    Giaz, A.
    Leoni, S.
    Million, B.
    Nicolini, R.
    Pellegri, L.
    Riboldi, S.
    Vandone, V.
    Wieland, O.
    Akkoyun, S.
    Atac, A.
    Bazzacco, D.
    Bellato, M.
    Bortolato, D.
    Calore, E.
    Ciemala, M.
    Farnea, E.
    Gadea, A.
    Gottardo, A.
    Kmiecik, M.
    Maj, A.
    Mengoni, D.
    Michelagnoli, C.
    Montanari, D.
    Napoli, D. R.
    Nyberg, J.
    Recchia, F.
    Sahin, E.
    Soderstrom, P. -A.
    Ur, C.
    Dobon, J. J. Valiente
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1147 - 1149
  • [36] EVALUATION OF ENERGY EFFICIENCY FITTING FUNCTIONS FOR HPGE DETECTORS
    SEYMOUR, RS
    ANDREACO, MS
    PIERCE, J
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1988, 123 (02): : 529 - 550
  • [37] Analog front ends for highly segmented detectors
    O'Connor, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 522 (1-2): : 126 - 130
  • [38] An advanced preamplifier for highly segmented germanium detectors
    Pullia, A.
    Zocca, F.
    Pascovici, G.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2869 - 2875
  • [39] Pulse shape analysis and position determination in segmented HPGe detectors: The AGATA detector library
    Bruyneel, B.
    Birkenbach, B.
    Reiter, P.
    EUROPEAN PHYSICAL JOURNAL A, 2016, 52 (03):
  • [40] Pulse shape analysis and position determination in segmented HPGe detectors: The AGATA detector library
    B. Bruyneel
    B. Birkenbach
    P. Reiter
    The European Physical Journal A, 2016, 52