Reproducibility of measurements with a new slit lamp-mounted ocular blood flow tonograph

被引:0
|
作者
C. W. Spraul
Gabriele E. Lang
Marina Ronzani
Josef Högel
Gerhard K. Lang
机构
[1] Department of Ophthalmology,
[2] University of Ulm,undefined
[3] Eye Clinic and Hospital,undefined
[4] Prittwitzstrasse 43,undefined
[5] D-89075 Ulm,undefined
[6] Germany Fax +49-731-50-27549; e-mail Christoph.Spraul@Medizin.Uni-Ulm.de,undefined
[7] Department of Statistics,undefined
[8] University of Ulm,undefined
[9] Ulm,undefined
[10] Germany,undefined
关键词
Blood Flow; Linear Regression; Regression Analysis; Regression Coefficient; Linear Regression Analysis;
D O I
暂无
中图分类号
学科分类号
摘要
· Purpose: To assess the reliability of measurements of intraocular pressure (IOP), pulse amplitude (PA), and pulsatile ocular blood flow (POBF) and the validity of measurements of IOP with a new ocular blood flow tonograph. · Methods: Intraocular pressure pulse was assessed with pneumatic tonometry. In this study, we used the OBF Labs ocular blood flow tonograph with two different pneumatic probes, a modified Langham probe and a newly developed probe. One ophthalmologist compared two machines, first with the modified Langham probe and secondly with the newly developed probe (40 volunteers). Additionally, two ophthalmologists performed measurements on different days and in different sequence (34 volunteers). Furthermore, results of IOP measurements performed with this tonograph were compared to those of Goldmann applanation tonometry (213 volunteers). · Results: Using the modified Langham probe, POBF and PA were associated with the machine used for the test. However, using the newly developed pobe, no relevant or statistically significant differences were found for any variables, and reliability coefficients were between 0.70 and 0.90. Linear regression analysis of the Goldmann applanation tonometer on the measurements of IOP with the tonograph showed a regression coefficient of 0.765. · Conclusions: Results of measurements performed with this ocular blood flow tonograph and the newly developed probe are expected to be reliable and comparable.
引用
收藏
页码:274 / 279
页数:5
相关论文
共 50 条
  • [31] SIGNIFICANCE AND REPRODUCIBILITY OF CALF BLOOD-FLOW MEASUREMENTS IN OCCLUSIVE VASCULAR DISEASE
    FOX, GC
    CAMPBELL, H
    MOTTRAM, RF
    HEARD, GE
    BRITISH JOURNAL OF SURGERY, 1965, 52 (08) : 628 - &
  • [32] SENSITIVITY AND CONCEPT ANALYSIS OF PULSATILE OCULAR BLOOD-FLOW MEASUREMENTS
    SILVER, DM
    FARRELL, RA
    KRAKAU, CET
    LANGHAM, ME
    SCHILDER, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 808 - 808
  • [33] The influence of sex difference in measurements with the Langham Ocular Blood Flow System
    Gekkieva, M
    Orgül, S
    Gherghel, D
    Gugleta, K
    Prünte, C
    Flammer, J
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2001, 45 (05) : 528 - 532
  • [34] RELIABILITY OF MEASUREMENTS USING THE LANGHAM OCULAR BLOOD-FLOW SYSTEM
    OPPENHEIM, B
    DICKERSIN, K
    MIN, YI
    SCHOCKET, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 940 - 940
  • [35] Hemodynamic indices for ocular blood flow from Doppler ultrasound measurements
    Silver, DM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1216 - 1216
  • [36] Ocular blood flow:: Reproducibility of Heidelberg Retina Flowmeter data and no effect of Metipranolol in healthy volunteers
    Funk, F
    Müller-Velten, R
    Ness, T
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2000, 217 (05) : 263 - 268
  • [37] Multiple Laser Doppler Flowmetry Probes Increase the Reproducibility of Skin Blood Flow Measurements
    Luck, J. Carter
    Kunselman, Allen R.
    Herr, Michael D.
    Blaha, Cheryl A.
    Sinoway, Lawrence I.
    Cui, Jian
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [38] High Reproducibility of Retinal Blood Flow Velocity Measurements Using the Retinal Function Imager
    Christian, K.
    Barash, H.
    Izhaky, D.
    Burgansky-Eliash, Z.
    Nelson, D. A.
    Barak, A.
    Lowenstein, A.
    Grinvald, A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [39] Segmental reproducibility of retinal blood flow velocity measurements using retinal function imager
    Chhablani, Jay
    Bartsch, Dirk-Uwe
    Cheng, Lingyun
    Gomez, Laura
    Alshareef, Rayan A.
    Rezeq, Sami S.
    Garg, Sunir J.
    Burgansky-Eliash, Zvia
    Freeman, William R.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (12) : 2665 - 2670
  • [40] Reproducibility of non-invasive blood flow measurements using loser Doppler spectroscopy
    Ghazanfari, M
    Vogt, L
    Banzer, W
    Rhodius, U
    PHYSIKALISCHE MEDIZIN REHABILITATIONSMEDIZIN KURORTMEDIZIN, 2002, 12 (06) : 330 - 336