Trueness and precision of intraoral scanners in the maxillary dental arch: an in vivo analysis

被引:0
|
作者
Jonas Winkler
Nikolaos Gkantidis
机构
[1] Department of Orthodontics and Dentofacial Orthopedics,
[2] University of Bern,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Intraoral three-dimensional imaging has gained great interest in dentistry as a mean to generate risk-free imprints of the oral cavity. Accurate intraoral models facilitate proper diagnosis, growth assessment, outcome evaluation, and 3D printing applications. Here, in an actual clinical setup on 12 subjects, we evaluate the trueness and precision of two widely used intraoral scanners (TRIOS 3, 3Shape and CS 3600, Carestream), using an industrial scanner (Artec Space Spider) as a reference. Surface based matching was implemented using the iterative closest point algorithm (ICP). Trueness of the intraoral scans was analyzed by measuring their distance from the reference scan, in the upper buccal front area. Precision was tested through the distance of repeated scans regarding the whole dental arch, following superimpositions in the buccal front and in the whole dental arch area. TRIOS 3 displayed slightly higher precision (approximately 10 μm) compared to CS 3600, only after superimposition on the whole dental arch (p < 0.05). Both intraoral scanners showed good performance and comparable trueness (median: 0.0154 mm; p> 0.05). However, in individual cases and in various, not spatially defined areas, higher imprecision was evident. Thus, the intraoral scanners’ appropriateness for highly demanding, spatially extended clinical applications remains questionable.
引用
收藏
相关论文
共 50 条
  • [21] Solid index versus intraoral scanners in the full-arch implant impression: in vitro trueness evaluation
    Mangano, Francesco Guido
    Bonacina, Matteo
    Mandelli, Federico
    Marchiori, Fabio
    BMC RESEARCH NOTES, 2020, 13 (01)
  • [22] Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study
    Mangano, Francesco Guido
    Hauschild, Uli
    Veronesi, Giovanni
    Imburgia, Mario
    Mangano, Carlo
    Admakin, Oleg
    BMC ORAL HEALTH, 2019, 19 (1)
  • [23] Trueness and Precision of Eight Intraoral Scanners with Different Finishing Line Designs: A Comparative In Vitro Study
    Falih, Mina Yahia
    Majeed, Manhal A.
    EUROPEAN JOURNAL OF DENTISTRY, 2023, 17 (04) : 1056 - 1064
  • [24] Solid index versus intraoral scanners in the full-arch implant impression: in vitro trueness evaluation
    Francesco Guido Mangano
    Matteo Bonacina
    Federico Mandelli
    Fabio Marchiori
    BMC Research Notes, 13
  • [25] In vivo full-arch accuracy of intraoral scanners: a narrative review
    Jennes, Marie-Elise
    Soetebeer, Maren
    Beuer, Florian
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2022, 25 (01) : 9 - 16
  • [26] Does partial adhesive preparation design and finish line depth influence trueness and precision of intraoral scanners?
    Baldi, Andrea
    Comba, Allegra
    Rozzi, Davide
    Pereira, Gabriel Kalil Rocha
    Valandro, Luiz Felipe
    Tempesta, Riccardo Michelotto
    Scotti, Nicola
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (04): : 637.e1 - 637.e9
  • [27] A Comparison of Full Arch Trueness and Precision of Nine Intra-Oral Digital Scanners and Four Lab Digital Scanners
    Nulty, Adam B.
    DENTISTRY JOURNAL, 2021, 9 (07)
  • [28] Effect of splinting scan bodies on the trueness of complete arch digital implant scans with 5 different intraoral scanners
    Azevedo, Luis
    Marques, Tiago
    Karasan, Duygu
    Fehmer, Vincent
    Sailer, Irena
    Correia, Andre
    Gomez-Polo, Miguel
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (01): : 204 - 210
  • [29] Evaluation of the trueness and precision of eight extraoral laboratory scanners with a complete-arch model: a three-dimensional analysis
    Emir, Faruk
    Ayyildiz, Simel
    JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (04) : 434 - 439
  • [30] Intraoral digital scans-Part 1: Influence of ambient scanning light conditions on the accuracy (trueness and precision) of different intraoral scanners
    Revilla-Leon, Marta
    Jiang, Peng
    Sadeghpour, Mehrad
    Piedra-Cascon, Wenceslao
    Zandinejad, Amirali
    Oezcan, Mutlu
    Krishnamurthy, Vinayak R.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (03): : 372 - 378