Does partial adhesive preparation design and finish line depth influence trueness and precision of intraoral scanners?

被引:4
|
作者
Baldi, Andrea [1 ]
Comba, Allegra [1 ]
Rozzi, Davide [1 ]
Pereira, Gabriel Kalil Rocha [2 ]
Valandro, Luiz Felipe [2 ]
Tempesta, Riccardo Michelotto [1 ]
Scotti, Nicola [1 ,3 ]
机构
[1] Dent Sch, Dept Surg Sci, Turin, Italy
[2] Fed Univ Santa Maria UFSM, Dept Restorat Dent, Div Prosthodont, Santa Maria, Brazil
[3] Dent Sch, Dept Surg Sci, 230 Via Nizza, I-10126 Turin, Italy
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2023年 / 129卷 / 04期
关键词
TOOTH PREPARATION DESIGN; IN-VITRO; RESTORATIONS; ACCURACY; IMPRESSIONS; ADAPTATION; THICKNESS;
D O I
10.1016/j.prosdent.2023.01.017
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Intraoral scanners (IOSs) are widely used for partial-coverage adhesive restorations, but data on their performance in such preparations with complex geometries are sparse.Purpose. The purpose of this in vitro study was to investigate whether the partial-coverage adhesive preparation design and finish line depth affect the trueness and precision of different IOSs.Material and methods. Seven partial-coverage adhesive preparation designs (4 different onlays, 2 endocrowns, and 1 occlusal veneer) were tested on copies of the same tooth placed in a typodont mounted on a mannequin. Each preparation was scanned 10 times with 6 different IOSs (total 420 scans) under the same light conditions. Trueness and precision, defined according to the International Organization for Standardization (ISO) 5725-1 standard, were analyzed with a best -fit algorithm by superimposition. The obtained data were analyzed by a 2-way analysis of variance to examine the effects of partial-coverage adhesive preparation design, IOS, and their interactions (a=.05).Results. Significant differences were found among different preparation designs and IOSs (P<.05) in terms of both trueness and precision. Significant differences were also found among mean positive and negative values (P<.05). Moreover, crosslinks observed between the preparation area and the adjacent teeth correlated with the finish line depth. Conclusions. Complex partial adhesive preparation designs affect the trueness and precision of IOSs, resulting in significant differences among them. Interproximal preparations should take into account the IOS's resolution and placing the finish line close to adjacent structures should be avoided.
引用
收藏
页码:637.e1 / 637.e9
页数:9
相关论文
共 7 条
  • [1] Effect of finish line locations of tooth preparation on the accuracy of intraoral scanners
    Son, Keunbada
    Lee, Kyu-Bok
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2021, 24 (01) : 29 - 40
  • [2] Trueness and Precision of Eight Intraoral Scanners with Different Finishing Line Designs: A Comparative In Vitro Study
    Falih, Mina Yahia
    Majeed, Manhal A.
    [J]. EUROPEAN JOURNAL OF DENTISTRY, 2023, 17 (04) : 1056 - 1064
  • [3] Intraoral digital scans-Part 1: Influence of ambient scanning light conditions on the accuracy (trueness and precision) of different intraoral scanners
    Revilla-Leon, Marta
    Jiang, Peng
    Sadeghpour, Mehrad
    Piedra-Cascon, Wenceslao
    Zandinejad, Amirali
    Oezcan, Mutlu
    Krishnamurthy, Vinayak R.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (03): : 372 - 378
  • [4] Influence of intraoral scanner and finish line location on the fabrication trueness and margin quality of additively manufactured laminate veneers fabricated with a completely digital workflow
    Cakmak, Guelce
    Chebaro, Jad
    Donmez, Mustafa Borga
    Yilmaz, Deniz
    Yoon, Hyung-In
    Kahveci, Cigdem
    Schimmel, Martin
    Yilmaz, Burak
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (02): : 313.e1 - 313.e9
  • [5] Influence of tooth preparation design and scan angulations on the accuracy of two intraoral digital scanners: An in vitro study based on 3-dimensional comparisons
    Ammoun, R.
    Suprono, M. S.
    Goodacre, C. J.
    Oyoyo, U.
    Carrico, C. K.
    Kattadiyil, M. T.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (06): : 785 - 785
  • [6] Influence of Tooth Preparation Design and Scan Angulations on the Accuracy of Two Intraoral Digital Scanners: An in Vitro Study Based on 3-Dimensional Comparisons
    Ammoun, Rami
    Suprono, Montry S.
    Goodacre, Charles J.
    Oyoyo, Udochukwu
    Carrico, Caroline K.
    Kattadiyil, Mathew T.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (03): : 201 - 206
  • [7] Stress distribution of inlay-anchored adhesive fixed partial dentures: A finite element analysis of the influence of restorative materials and abutment preparation design
    Magne, P
    Perakis, N
    Belser, UC
    Krejci, I
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (05): : 516 - 527