Optimizing contrast medium injection protocol individually with body weight for high-pitch prospective ECG-triggering coronary CT angiography

被引:0
|
作者
Jie Liu
Jianbo Gao
Runze Wu
Yonggao Zhang
Lili Hu
Ping Hou
机构
[1] The First Affiliated Hospital of Zhengzhou University,Department of Radiology
[2] Siemens Healthcare,undefined
关键词
Contrast medium; Coronary computed tomography angiography; High-pitch; Low dose; Image quality;
D O I
暂无
中图分类号
学科分类号
摘要
To individually optimize contrast medium protocol for high-pitch prospective ECG-triggering coronary CT angiography using body weight. Ninety patients undergoing high-pitch coronary CT angiography were randomly assigned to 3 contrast medium injection protocols with bolus tracking technique: Group A, 0.7 ml CM per kg patient weight (ml/kg); Group B, 0.6 ml/kg; Group C, 0.5 ml/kg. Each group had 30 patients. The CT values of superior vena cava (SVC), pulmonary artery (PA), ascending aorta (AA), left atrium (LA), left ventricle (LV), left main artery (LM) and proximal segment of right coronary artery (RCA) were measured. The image quality of coronary artery was evaluated on per-segment basis using a 4-point scale (1-excellent, 4-non-diagnosis). The CT value was not significantly different on AA (p = 0.735), LM (p = 0.764), and proximal segment of RCA (p = 0.991). The CT value was significantly different on SVC, PA, LA and LV (all p < 0.05). The mean image quality score was 1.6 ± 0.1, 1.6 ± 0.1 and 1.6 ± 0.1 (p = 0.217). The volume of CM was 47 ± 8, 44 ± 8 and 36 ± 6 ml for 3 groups (p < 0.001). The effective radiation dose was 0.88 ± 0.04, 0.87 ± 0.06, and 0.85 ± 0.07 mSv for 3 groups. Contrast medium could be reduced to 0.5 ml/kg for high-pitch coronary CT angiography without compromising diagnostic image quality, which associated ~50 % reduction of total contrast volume compared with standard contrast protocol with test bolus technique.
引用
收藏
页码:1115 / 1120
页数:5
相关论文
共 50 条
  • [41] Minimizing the radiation dose in coronary CT angiography using prospective ECG-triggering, low tube voltage and iterative reconstruction technologies
    Saglam, Muzaffer
    Ozturk, Ersin
    Kara, Kemal
    JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (01) : 46 - 47
  • [42] LOW-DOSE CT CORONARY ANGIOGRAPHY WITH PROSPECTIVE ECG-TRIGGERING ACCURATELY PREDICTS EVENTS IN PATIENTS WITH KNOWN OR SUSPECTED CORONARY ARTERY DISEASE
    Buechel, Ronny R.
    Pazhenkottil, Aju P.
    Herzog, Bernhard A.
    Nkoulou, Rene N.
    Burger, Irene A.
    Valenta, Ines
    Wyss, Christophe A.
    Husmann, Lars
    Kaufmann, Philipp A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [43] Double prospectively ECG-triggered high-pitch spiral acquisition for CT coronary angiography: Initial experience
    Wang, Q.
    Qin, J.
    He, B.
    Zhou, Y.
    Yang, J-J
    Hou, X. -L.
    Yang, X. -B.
    Chen, J. -H.
    Chen, Y. -D.
    CLINICAL RADIOLOGY, 2013, 68 (08) : 792 - 798
  • [44] Body physique and heart rate variability determine the occurrence of stair-step artefacts in 64-slice CT coronary angiography with prospective ECG-triggering
    Lars Husmann
    Bernhard A. Herzog
    Nina Burkhard
    Fuminari Tatsugami
    Ines Valenta
    Oliver Gaemperli
    Christophe A. Wyss
    Ulf Landmesser
    Philipp A. Kaufmann
    European Radiology, 2009, 19 : 1698 - 1703
  • [45] Body physique and heart rate variability determine the occurrence of stair-step artefacts in 64-slice CT coronary angiography with prospective ECG-triggering
    Husmann, Lars
    Herzog, Bernhard A.
    Burkhard, Nina
    Tatsugami, Fuminari
    Valenta, Ines
    Gaemperli, Oliver
    Wyss, Christophe A.
    Landmesser, Ulf
    Kaufmann, Philipp A.
    EUROPEAN RADIOLOGY, 2009, 19 (07) : 1698 - 1703
  • [46] Evaluability and diagnostic accuracy of a low radiation exposure protocol for prospective ECG-triggering coronary multidetector computed tomography angiography in detection of coronary artery disease
    Pontone, G.
    Andreini, D.
    Bertella, E.
    Mushtaq, S.
    Formenti, A.
    Annoni, A. D.
    Ballerini, G.
    Fiorentini, C.
    Bartorelli, A. L.
    Pepi, M.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A23 - A23
  • [47] In reply to: Minimizing the radiation dose in coronary CT angiography using prospective ECG-triggering, low tube voltage and iterative reconstruction technologies
    Nobuo Tomizawa
    Shigeaki Kanno
    Eriko Maeda
    Masaaki Akahane
    Rumiko Torigoe
    Kuni Ohtomo
    Japanese Journal of Radiology, 2015, 33 : 48 - 49
  • [48] Optimization of contrast medium protocol in CT coronary arteriography: constant injection dose rate adapted to body weight
    Cao, Lizhen
    Du, Xiangying
    Li, Pengyu
    Sun, Zheng
    Zhang, Qiuhang
    Li, Kuncheng
    ACTA RADIOLOGICA, 2011, 52 (06) : 608 - 612
  • [49] Evaluability and diagnostic accuracy of a low radiation exposure protocol for prospective ECG-triggering coronary multidetector computed tomography angiography in detection of coronary artery disease
    Pontone, G.
    Andreini, D.
    Bertella, E.
    Mushtaq, S.
    Formenti, A.
    Annoni, A. D.
    Ballerini, G.
    Fiorentini, C.
    Bartorelli, A. L.
    Pepi, M.
    EUROPEAN HEART JOURNAL, 2010, 31 : 133 - 133
  • [50] Is ECG triggering for motion artefact reduction in dual-source CT angiography of the ascending aorta still required with high-pitch scanning? The role of ECG-gating in high-pitch dual-source CT of the ascending aorta
    Wielandner, Alice
    Beitzke, Dietrich
    Schernthaner, Ruediger
    Wolf, Florian
    Langenberger, Christina
    Stadler, Alfred
    Loewe, Christian
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1064):