Optimizing contrast medium injection protocol individually with body weight for high-pitch prospective ECG-triggering coronary CT angiography

被引:0
|
作者
Jie Liu
Jianbo Gao
Runze Wu
Yonggao Zhang
Lili Hu
Ping Hou
机构
[1] The First Affiliated Hospital of Zhengzhou University,Department of Radiology
[2] Siemens Healthcare,undefined
关键词
Contrast medium; Coronary computed tomography angiography; High-pitch; Low dose; Image quality;
D O I
暂无
中图分类号
学科分类号
摘要
To individually optimize contrast medium protocol for high-pitch prospective ECG-triggering coronary CT angiography using body weight. Ninety patients undergoing high-pitch coronary CT angiography were randomly assigned to 3 contrast medium injection protocols with bolus tracking technique: Group A, 0.7 ml CM per kg patient weight (ml/kg); Group B, 0.6 ml/kg; Group C, 0.5 ml/kg. Each group had 30 patients. The CT values of superior vena cava (SVC), pulmonary artery (PA), ascending aorta (AA), left atrium (LA), left ventricle (LV), left main artery (LM) and proximal segment of right coronary artery (RCA) were measured. The image quality of coronary artery was evaluated on per-segment basis using a 4-point scale (1-excellent, 4-non-diagnosis). The CT value was not significantly different on AA (p = 0.735), LM (p = 0.764), and proximal segment of RCA (p = 0.991). The CT value was significantly different on SVC, PA, LA and LV (all p < 0.05). The mean image quality score was 1.6 ± 0.1, 1.6 ± 0.1 and 1.6 ± 0.1 (p = 0.217). The volume of CM was 47 ± 8, 44 ± 8 and 36 ± 6 ml for 3 groups (p < 0.001). The effective radiation dose was 0.88 ± 0.04, 0.87 ± 0.06, and 0.85 ± 0.07 mSv for 3 groups. Contrast medium could be reduced to 0.5 ml/kg for high-pitch coronary CT angiography without compromising diagnostic image quality, which associated ~50 % reduction of total contrast volume compared with standard contrast protocol with test bolus technique.
引用
收藏
页码:1115 / 1120
页数:5
相关论文
共 50 条
  • [21] High-Pitch Coronary CT Angiography at 70 kVp With Low Contrast Medium Volume Comparison of 80 and 100 kVp High-Pitch Protocols
    Zhang, Long Jiang
    Qi, Li
    De Cecco, Carlo N.
    Zhou, Chang Sheng
    Spearman, James V.
    Schoepf, U. Joseph
    Lu, Guang Ming
    MEDICINE, 2014, 93 (22)
  • [22] Revival of monophasic contrast injection protocols: superiority of a monophasic injection protocol compared to a biphasic injection protocol in high-pitch CT angiography
    Apitzsch, Jonas
    Jost, Gregor
    Bonifer, Elisabeth
    Keulers, Annika
    Pietsch, Hubertus
    Mahnken, Andreas Horst
    ACTA RADIOLOGICA, 2016, 57 (10) : 1210 - 1216
  • [23] Feasibility and diagnostic accuracy of a low radiation exposure protocol for prospective ECG-triggering coronary MDCT angiography
    Pontone, G.
    Andreini, D.
    Bartorelli, A. L.
    Bertella, E.
    Mushtaq, S.
    Foti, C.
    Formenti, A.
    Chiappa, L.
    Annoni, A.
    Cortinovis, S.
    Baggiano, A.
    Conte, E.
    Bovis, F.
    Veglia, F.
    Ballerini, G.
    Agostoni, P.
    Fiorentini, C.
    Pepi, M.
    CLINICAL RADIOLOGY, 2012, 67 (03) : 207 - 215
  • [24] Validation of a Body Mass Index Adapted Scanning Protocol for Low-Dose 64-Slice CT Coronary Angiography with Prospective ECG-Triggering
    Tatsugami, Fuminari
    Husmann, Lars
    Herzog, Bernhard A.
    Burkhard, Nina
    Valenta, Ines
    Gaemperli, Oliver
    Wyss, Christophe A.
    Landmesser, Ulf
    Kaufmann, Philipp A.
    CIRCULATION, 2008, 118 (18) : S1006 - S1006
  • [25] Low-dose 64-slice CT Coronary Angiography with Prospective ECG-triggering: Optimized Body Mass Index adapted Scanning Protocol
    Husmann, Lars L.
    Tatsugami, F.
    Herzog, B. A.
    Burkhard, N.
    Valenta, I.
    Gaemperli, O.
    Wyss, C. A.
    Kaufmann, P. A.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S85 - S85
  • [26] Radiation dose in coronary CT angiography associated with prospective ECG-triggering technique: comparisons with different CT generations
    Sabarudin, Akmal
    Sun, Zhonghua
    Ng, Kwan-Hoong
    RADIATION PROTECTION DOSIMETRY, 2013, 154 (03) : 301 - 307
  • [27] Reduction of X-Ray Induced DNA Double-Strand Breaks in Blood Lymphocytes During Coronary CT Angiography Using High-Pitch Spiral Data Acquisition With Prospective ECG-Triggering
    Kuefner, Michael A.
    Hinkmann, Fabian M.
    Alibek, Sedat
    Azoulay, Sascha
    Anders, Katharina
    Kalender, Willi A.
    Achenbach, Stephan
    Grudzenski, Saskia
    Loebrich, Markus
    Uder, Michael
    INVESTIGATIVE RADIOLOGY, 2010, 45 (04) : 182 - 187
  • [28] Low-Dose Coronary CT Angiography With Prospective ECG Triggering: Validation of a Contrast Material Protocol Adapted to Body Mass Index
    Husmann, Lars
    Herzog, Bernhard A.
    Burkhard, Nina
    Valenta, Ines
    Burger, Irene A.
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) : 802 - 806
  • [29] Evaluation of image quality on low contrast media with deep learning image reconstruction algorithm in prospective ECG-triggering coronary CT angiography
    Yuan, Dian
    Wang, Luotong
    Lyu, Peijie
    Zhang, Yonggao
    Gao, Jianbo
    Liu, Jie
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2024, 40 (06): : 1377 - 1388
  • [30] Body Physique and Heart Rate Variability Determine the Occurrence of Stair-Step Artifacts in CT Coronary Angiography with Prospective ECG-Triggering
    Husmann, L.
    Herzog, B. A.
    Burkhard, N.
    Tatsugami, F.
    Valenta, I.
    Gaemperli, O.
    Wyss, C. A.
    Kaufmann, P. A.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S85 - S86