Optimizing contrast medium injection protocol individually with body weight for high-pitch prospective ECG-triggering coronary CT angiography

被引:0
|
作者
Jie Liu
Jianbo Gao
Runze Wu
Yonggao Zhang
Lili Hu
Ping Hou
机构
[1] The First Affiliated Hospital of Zhengzhou University,Department of Radiology
[2] Siemens Healthcare,undefined
关键词
Contrast medium; Coronary computed tomography angiography; High-pitch; Low dose; Image quality;
D O I
暂无
中图分类号
学科分类号
摘要
To individually optimize contrast medium protocol for high-pitch prospective ECG-triggering coronary CT angiography using body weight. Ninety patients undergoing high-pitch coronary CT angiography were randomly assigned to 3 contrast medium injection protocols with bolus tracking technique: Group A, 0.7 ml CM per kg patient weight (ml/kg); Group B, 0.6 ml/kg; Group C, 0.5 ml/kg. Each group had 30 patients. The CT values of superior vena cava (SVC), pulmonary artery (PA), ascending aorta (AA), left atrium (LA), left ventricle (LV), left main artery (LM) and proximal segment of right coronary artery (RCA) were measured. The image quality of coronary artery was evaluated on per-segment basis using a 4-point scale (1-excellent, 4-non-diagnosis). The CT value was not significantly different on AA (p = 0.735), LM (p = 0.764), and proximal segment of RCA (p = 0.991). The CT value was significantly different on SVC, PA, LA and LV (all p < 0.05). The mean image quality score was 1.6 ± 0.1, 1.6 ± 0.1 and 1.6 ± 0.1 (p = 0.217). The volume of CM was 47 ± 8, 44 ± 8 and 36 ± 6 ml for 3 groups (p < 0.001). The effective radiation dose was 0.88 ± 0.04, 0.87 ± 0.06, and 0.85 ± 0.07 mSv for 3 groups. Contrast medium could be reduced to 0.5 ml/kg for high-pitch coronary CT angiography without compromising diagnostic image quality, which associated ~50 % reduction of total contrast volume compared with standard contrast protocol with test bolus technique.
引用
收藏
页码:1115 / 1120
页数:5
相关论文
共 50 条
  • [1] Optimizing contrast medium injection protocol individually with body weight for high-pitch prospective ECG-triggering coronary CT angiography
    Liu, Jie
    Gao, Jianbo
    Wu, Runze
    Zhang, Yonggao
    Hu, Lili
    Hou, Ping
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05): : 1115 - 1120
  • [2] Accuracy of high-pitch prospectively ECG-triggering CT coronary angiography for assessment of stenosis in 103 patients: Comparison with invasive coronary angiography
    Hu, X. H.
    Zheng, W. L.
    Wang, D.
    Xie, S. S.
    Wu, R.
    Zhang, S. Z.
    CLINICAL RADIOLOGY, 2012, 67 (11) : 1083 - 1088
  • [3] Coronary CT angiography with prospective ECG-triggering: an effective alternative to invasive coronary angiography
    Sun, Zhonghua
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2012, 2 (01) : 28 - 37
  • [4] Accuracy of low dose CT coronary angiography with prospective ECG-triggering
    Herzog, Bernhard Alexandre B. A.
    Husmann, L.
    Burkhard, N.
    Gaemperli, O.
    Valenta, I.
    Wyss, C. A.
    Landmesser, U.
    Kaufmann, P. A.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S83 - S83
  • [5] Evidence for prospective ECG-triggering coronary CT angiography in routine practice
    Ali Salavati
    Frank J. Rybicki
    The International Journal of Cardiovascular Imaging, 2012, 28 : 2121 - 2124
  • [6] Evidence for prospective ECG-triggering coronary CT angiography in routine practice
    Salavati, Ali
    Rybicki, Frank J.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (08): : 2121 - 2124
  • [7] Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography
    Harald Seifarth
    Michael Puesken
    John F. Kalafut
    Susanne Wienbeck
    Johannes Wessling
    David Maintz
    Walter Heindel
    Kai-Uwe Juergens
    European Radiology, 2009, 19 : 2373 - 2382
  • [8] Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography
    Seifarth, Harald
    Puesken, Michael
    Kalafut, John F.
    Wienbeck, Susanne
    Wessling, Johannes
    Maintz, David
    Heindel, Walter
    Juergens, Kai-Uwe
    EUROPEAN RADIOLOGY, 2009, 19 (10) : 2373 - 2382
  • [9] High-Pitch Coronary CT Angiography at 70 kVp Adopting a Protocol of Low Injection Speed and Low Volume of Contrast Medium
    Feng, Ruiqi
    Tong, Jiajie
    Liu, Xiaofei
    Zhao, Yu
    Zhang, Liang
    KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (05) : 763 - 772
  • [10] Validation of a new contrast material protocol adapted to body surface area for optimized low-dose CT coronary angiography with prospective ECG-triggering
    Pazhenkottil, Aju P.
    Husmann, Lars
    Buechel, Ronny R.
    Herzog, Bernhard A.
    Nkoulou, Rene
    Burger, Irene A.
    Vetterli, Andrea
    Valenta, Ines
    Ghadri, Jelena R.
    von Schulthess, Patrick
    Kaufmann, Philipp A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (05): : 591 - 597