Functional imaging with MR T1 contrast: a feasibility study with blood-pool contrast agent

被引:0
|
作者
Agata Majos
Piotr Bogorodzki
Ewa Piątkowska-Janko
Tomasz Wolak
Robert Kurjata
Ludomir Stefańczyk
机构
[1] Medical University of Lodz,Radiology Department
[2] Warsaw University of Technology,Institute of Radioelectronics
[3] Institute of Physiology and Pathology of Hearing,undefined
来源
European Radiology | 2009年 / 19卷
关键词
Blood oxygen level-dependent effect; CBV; Functional MRI; Contrast media;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to prove the concept of using a long intravenous half-life blood-pool T1 contrast agent as a new functional imaging method. For each of ten healthy subjects, two dynamic magnetic resonance (MR) protocols were carried out: (1) a reference run with a typical T2* echo-planar imaging (EPI) sequence based on the blood oxygenation level-dependent (BOLD) effect and (2) a run with a T1-sensitive three-dimensional (3D) gradient-echo (GRE) sequence using cerebral blood volume (CBV) contrast after intravenous administration of a contrast agent containing a chelate of gadolinium diethylene-triamine-pentaacetate with a phosphono-oxymethyl substituent. All sequences were performed during the execution of a block-type finger-tapping paradigm. SPM5 software was used for statistical analysis. For both runs maximum activations (peak Z-score = 5.5, cluster size 3,449 voxels) were localized in the left postcentral gyrus. Visual inspection of respective signal amplitudes suggests the T1 contrast to be substantially smaller than EPI (0.5% vs 1%). A new functional imaging method with potentially smaller image artefacts due to the nature of CBV contrast and characteristics of the T1 sequence was proposed and verified.
引用
收藏
页码:898 / 903
页数:5
相关论文
共 50 条
  • [41] Value of blood pool MR contrast agents in imaging of the heart and blood vessels
    Saeed, M
    DRUGS OF TODAY, 1999, 35 (11) : 879 - 892
  • [42] New blood pool MR imaging contrast agent (NC100150) for diagnosis of pulmonary embolism
    Steiner, P
    Weber, C
    Welger, J
    Miesbach, C
    Sievers, J
    Hoffmann, VW
    RADIOLOGY, 1999, 213P : 473 - 473
  • [43] Intravascular contrast agent T1 shortening:: fast T1 relaxometry in a carotid volunteer study
    Bock, Michael
    Schulz, Jessica
    Ueltzhoeffer, Stefan
    Giesel, Frederik
    Voth, Matthias
    Essig, Marco
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2008, 21 (05) : 363 - 368
  • [44] Intravascular contrast agent T1 shortening: fast T1 relaxometry in a carotid volunteer study
    Michael Bock
    Jessica Schulz
    Stefan Ueltzhoeffer
    Frederik Giesel
    Matthias Voth
    Marco Essig
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2008, 21 : 363 - 368
  • [45] Assessment of peritoneal tolerance of a new MR blood pool contrast agent in rabbits
    Hilfiker, PR
    Debatin, JF
    Tarlo, K
    Schmitz, HC
    Kurrer, MO
    INVESTIGATIVE RADIOLOGY, 1999, 34 (11) : 722 - 727
  • [46] The macromolecular blood-pool MR-contrast agent gadomelitol improves tumor detection in an orthotopic rat model for hepatocellular carcinoma.
    Semela, D
    Redaelli, CA
    Ayuni, E
    Froehlich, JM
    Froehlich, JM
    Schindera, S
    Ledermann, M
    Dufour, JF
    Stoupis, C
    HEPATOLOGY, 2004, 40 (04) : 708A - 709A
  • [47] Gadolinium-DTPA-dextran: A macromolecular MR blood pool contrast agent
    Sirlin, CB
    Vera, DR
    Corbeil, JA
    Caballero, MB
    Buxton, RB
    Mattrey, RF
    ACADEMIC RADIOLOGY, 2004, 11 (12) : 1361 - 1369
  • [48] A manganese porphyrin-based T1 contrast agent for cellular MR imaging of human embryonic stem cells
    Venter, Andrei
    Szulc, Daniel A.
    Loai, Sadi
    Ganesh, Tameshwar
    Haedicke, Inga E.
    Cheng, Hai-Ling Margaret
    SCIENTIFIC REPORTS, 2018, 8
  • [49] A manganese porphyrin-based T1 contrast agent for cellular MR imaging of human embryonic stem cells
    Andrei Venter
    Daniel A. Szulc
    Sadi Loai
    Tameshwar Ganesh
    Inga E. Haedicke
    Hai-Ling Margaret Cheng
    Scientific Reports, 8
  • [50] Contrast-enhanced blood-pool MR angiography with optimized iron oxides: Effect of size and dose on vascular contrast enhancement in rabbits
    Allkemper, T
    Bremer, C
    Matuszewski, L
    Ebert, W
    Reimer, P
    RADIOLOGY, 2002, 223 (02) : 432 - 438