Contrast-enhanced blood-pool MR angiography with optimized iron oxides: Effect of size and dose on vascular contrast enhancement in rabbits

被引:106
|
作者
Allkemper, T
Bremer, C
Matuszewski, L
Ebert, W
Reimer, P
机构
[1] Univ Hosp Munster, Dept Clin Radiol, D-48129 Munster, Germany
[2] Schering AG, D-1000 Berlin, Germany
关键词
contrast media; comparative studies; experimental studies; gadolinium; magnetic resonance (MR); vascular studies;
D O I
10.1148/radiol.2232010241
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate intravascular enhancement of bolus-injectable small and ultrasmall superparamagnetic iron oxides (USP10s) of different particle sizes and relaxivities for first-pass and blood-pool magnetic resonance (MR) angiography. MATERIALS AND METHODS: Iron oxides with different particle sizes (hydrodynamic diameters, 21, 33, 46, and 65 nm) were bolus injected intravenously at three doses (10, 20, and 40 mumol per kilogram body weight). An extracellular contrast agent (gadopentetate dimeglumine) served as a control. MR angiography was performed multiple times after intravenous injection (5-120 minutes and 24 hours later). Signal enhancement was calculated from signal intensity measurements in the abdominal aorta and renal and iliac arteries. RESULTS: Highest enhancement was seen during the first pass with all contrast agents. USPIO enhancement in the abdominal aorta increased significantly with decreasing particle size (65 nm vs 33 nm, 65 nm vs 21 nm; P < .01). CONCLUSION: The smallest iron oxide provided signal enhancement comparable with that of gadopentetate dimeglumine at 40 mumol iron per kilogram for first-pass investigations, with prolonged signal enhancement up to 25 minutes, allowing multiple measurements after injection of a single bolus. (C) RSNA, 2002.
引用
收藏
页码:432 / 438
页数:7
相关论文
共 50 条
  • [1] Blood Pool Contrast-Enhanced MR Angiography With Correlation to Digital Subtraction Angiography
    Kowalski, J.
    Knuttinen, M.
    Mar, W.
    Khiatani, V
    Golden, M.
    Xie, K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [2] The "Track Sign": delayed blood-pool phase contrast-enhanced MR angiography shows acute large vessel occlusion
    Swartz, R. H.
    Silver, F. L.
    Vergouwen, M. D.
    Mikulis, D. J.
    Farb, R., I
    STROKE, 2010, 41 (07) : E488 - E488
  • [3] Dose optimization of contrast-enhanced carotid MR angiography
    Unterweger, M
    Froehlich, JM
    Kubik-Huch, RA
    Seifert, B
    Birrer, M
    Huber, T
    Otto, R
    EUROPEAN RADIOLOGY, 2005, 15 (09) : 1797 - 1805
  • [4] Dose optimization of contrast-enhanced carotid MR angiography
    M. Unterweger
    J. M. Froehlich
    R. A. Kubik-Huch
    B. Seifert
    M. Birrer
    T. Huber
    R. Otto
    European Radiology, 2005, 15 : 1797 - 1805
  • [5] Contrast-enhanced MR angiography of thoracic vascular malformations in children
    Fitoz, Suat
    Unsal, Nuray
    Tekin, Mustafa
    Tutar, Ercan
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 123 (01) : 3 - 11
  • [6] Pulmonary MR angiography with blood pool contrast agent: Effects of dose, echo time, and flip angle on vascular enhancement
    Bremerich, J
    Saeed, M
    Roberts, TP
    Wendland, MF
    Wyttenbach, R
    Higgins, CB
    RADIOLOGY, 1998, 209P : 356 - 356
  • [7] Effect of contrast dilution on contrast-enhanced MR angiography of the aorta and renal arteries
    Jean-Pierre Laissy
    David Menegazzo
    Marie-Pierre Debray
    Sylvie Chillon
    Pascale Karila-Cohen
    Abdenasser Daikha
    Elisabeth Schouman-Claeys
    European Radiology, 2001, 11 : 1198 - 1205
  • [8] Effect of contrast dilution on contrast-enhanced MR angiography of the aorta and renal arteries
    Laissy, JP
    Menegazzo, D
    Debray, MP
    Chillon, S
    Karila-Cohen, P
    Daikha, A
    Schouman-Claeys, E
    EUROPEAN RADIOLOGY, 2001, 11 (07) : 1198 - 1205
  • [9] Abdominopelvic and Lower Extremity Deep Venous Thrombosis: Evaluation With Contrast-Enhanced MR Venography With a Blood-Pool Agent
    Huang, Steven Y.
    Kim, Charles Y.
    Miller, Michael J.
    Gupta, Rajan T.
    Lessne, Mark L.
    Horvath, Jeffrey J.
    Boll, Daniel T.
    Evans, Paul D.
    Befera, Nicholas T.
    Krishnan, Pranay
    Chan, Johanna L.
    Merkle, Elmar M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (01) : 208 - 214
  • [10] Visualization techniques for blood pool contrast-enhanced magnetic resonance angiography
    Yucel, EK
    ACADEMIC RADIOLOGY, 2002, 9 : S140 - S142