Ag or Au Nanoparticles Decorated Multiwalled Carbon Nanotubes Coated Carbon Paste Electrodes for Amperometric Determination of H2O2

被引:0
|
作者
Valéria Guzsvány
Olga Vajdle
Milana Gurdeljević
Zoltán Kónya
机构
[1] University of Novi Sad,Department of Chemistry, Biochemistry and Environmental Protection, Faculty of Sciences
[2] University of Szeged,Department of Applied and Environmental Chemistry
[3] MTA-SZTE Reaction Kinetics and Surface Chemistry Research Group,undefined
来源
Topics in Catalysis | 2018年 / 61卷
关键词
Au-MWCNT; Ag-MWCNT; H; O; determination; Voltammetry; CPE; Nursing product; Mediator based electrocatalytic signal enhancement;
D O I
暂无
中图分类号
学科分类号
摘要
Composite materials made of multiwalled carbon nanotubes and silver (Ag-MWCNT) or gold particles (Au-MWCNT) were synthesized and characterized by XRD and SEM/EDS techniques. The composites and the MWCNTs were applied as surface modifiers of carbon paste electrodes (CPEs). The mediator based electrocatalytic activity of the modified electrodes was investigated for H2O2 oxidation/reduction by electrochemical measurements. All voltammetric working electrodes (Ag-MWCNT/CPE, Au-MWCNT/CPE, MWCNT/CPE and the bare CPE) were characterized by cyclic voltammetry (CV) in acetate and phosphate supporting electrolytes (0.1 mol L−1, pH 4.50 and 7.50, respectively) in the absence and presence of the H2O2 analyte. Amperometric experiments were performed in stirred solutions at selected constant working potentials, in accordance with the CV responses, for developing new analytical methods for the determination of H2O2. In the case of the Ag-MWCNT/CPE the most promising working potentials in the acetate buffer solution were − 0.40 V and + 0.80 versus SCE; in phosphate buffer solution these values were between − 0.20 and − 0.30 V and from + 0.60 to + 1.0 V. The Au-MWCNT/CPE is applicable in acetate buffer supporting electrolyte in the working potential close to − 0.30 V versus SCE and from + 0.70 to + 1.0 V; in the phosphate buffer solution only from + 0.60 V versus SCE and higher values. Due to the presence of the signal enhancement effect of Au and Ag nanoparticles, the sensitivity of the obtained methods is significantly higher in comparison to the results obtained by the MWCNT/CPE and bare CPE. The relative standard deviation of the measurements was lower than 10%. The practical application using the Ag-MWCNT/CPE was shown for the determination of H2O2 in real nursing product sample. It was proven that the developed mediator based (electro)catalytic platform exhibits low detection limit, high selectivity, reproducibility and stability.
引用
收藏
页码:1350 / 1361
页数:11
相关论文
共 50 条
  • [21] An amperometric H2O2 biosensor based on cytochrome c immobilized onto nickel oxide nanoparticles/carboxylated multiwalled carbon nanotubes/polyaniline modified gold electrode
    Lata, Suman
    Batra, Bhawna
    Karwasra, Neelam
    Pundir, Chandra S.
    PROCESS BIOCHEMISTRY, 2012, 47 (06) : 992 - 998
  • [22] Cobalt ferrite nanoparticles decorated on exfoliated graphene oxide, application for amperometric determination of NADH and H2O2
    Ensafi, Ali A.
    Alinajafi, Hossein A.
    Jafari-Asl, M.
    Rezaei, B.
    Ghazaei, F.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 60 : 276 - 284
  • [23] Electrochemical Sensor Based on Carbon Nanotubes Decorated with ZnFe2O4 Nanoparticles Incorporated Carbon Paste Electrode for Determination of Metoclopramide and Indomethacin
    Hassannezhad, Morassa
    Hosseini, Morteza
    Ganjali, Mohammad Reza
    Arvand, Majid
    CHEMISTRYSELECT, 2019, 4 (25): : 7616 - 7626
  • [24] Application Of Multiwalled Carbon Nanotubes-Graphene Hybrid Nanocomposite For Nonenzymatic H2O2 Biosensor
    Nayak, Pranati
    Santhosh, P. N.
    Ramaprabhu, S.
    SOLID STATE PHYSICS, VOL 57, 2013, 1512 : 374 - 375
  • [25] COMPARATIVE STUDY OF CARBON PASTE ELECTRODES MODIFIED WITH METHYLENE BLUE AND METHYLENE GREEN ADSORBED ON ZEOLITE AS AMPEROMETRIC SENSORS FOR H2O2 DETECTION
    Varodi, Codruta
    Gligor, Delia
    Abodi, Levente
    Muresan, Liana Maria
    STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2009, 54 (03): : 255 - 263
  • [26] Poly (Toluidine Blue) and Zirconia Nanoparticles Electrochemically Deposited at Gelatin-Multiwalled Carbon Nanotube Film for Amperometric H2O2 Sensor
    Chang, Yu-Jung
    Periasamy, Arun Prakash
    Chen, Shen-Ming
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (09): : 4188 - 4203
  • [27] Enhancement of H2O2 current at electrodes made of Fenton-Activated carbon nanotubes
    Lucio-Rivera, Zachary
    Gudgel, Robert
    Smith, Austin
    Gorski, Waldemar
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2024, 956
  • [28] Voltammetric determination of uric acid with a glassy carbon electrode coated by paste of multiwalled carbon nanotubes and ionic liquid
    Yan, Quanping
    Zhao, Faqiong
    Li, Guangzu
    Zeng, Baizhao
    ELECTROANALYSIS, 2006, 18 (11) : 1075 - 1080
  • [29] Fabrication of a novel electrochemiluminescence glucose biosensor using Au nanoparticles decorated multiwalled carbon nanotubes
    Haghighi, Behzad
    Bozorgzadeh, Somayyeh
    Gorton, Lo
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 155 (02) : 577 - 583
  • [30] Rapid amperometric determination of H2O2 by a Pt nanoparticle/Vulcan XC72 composite-coated carbon paste electrode in disinfection and contact lens solutions
    Jasmina Anojčić
    Valéria Guzsvány
    Olga Vajdle
    Zoltán Kónya
    Kurt Kalcher
    Monatshefte für Chemie - Chemical Monthly, 2018, 149 : 1727 - 1738