Ag or Au Nanoparticles Decorated Multiwalled Carbon Nanotubes Coated Carbon Paste Electrodes for Amperometric Determination of H2O2

被引:0
|
作者
Valéria Guzsvány
Olga Vajdle
Milana Gurdeljević
Zoltán Kónya
机构
[1] University of Novi Sad,Department of Chemistry, Biochemistry and Environmental Protection, Faculty of Sciences
[2] University of Szeged,Department of Applied and Environmental Chemistry
[3] MTA-SZTE Reaction Kinetics and Surface Chemistry Research Group,undefined
来源
Topics in Catalysis | 2018年 / 61卷
关键词
Au-MWCNT; Ag-MWCNT; H; O; determination; Voltammetry; CPE; Nursing product; Mediator based electrocatalytic signal enhancement;
D O I
暂无
中图分类号
学科分类号
摘要
Composite materials made of multiwalled carbon nanotubes and silver (Ag-MWCNT) or gold particles (Au-MWCNT) were synthesized and characterized by XRD and SEM/EDS techniques. The composites and the MWCNTs were applied as surface modifiers of carbon paste electrodes (CPEs). The mediator based electrocatalytic activity of the modified electrodes was investigated for H2O2 oxidation/reduction by electrochemical measurements. All voltammetric working electrodes (Ag-MWCNT/CPE, Au-MWCNT/CPE, MWCNT/CPE and the bare CPE) were characterized by cyclic voltammetry (CV) in acetate and phosphate supporting electrolytes (0.1 mol L−1, pH 4.50 and 7.50, respectively) in the absence and presence of the H2O2 analyte. Amperometric experiments were performed in stirred solutions at selected constant working potentials, in accordance with the CV responses, for developing new analytical methods for the determination of H2O2. In the case of the Ag-MWCNT/CPE the most promising working potentials in the acetate buffer solution were − 0.40 V and + 0.80 versus SCE; in phosphate buffer solution these values were between − 0.20 and − 0.30 V and from + 0.60 to + 1.0 V. The Au-MWCNT/CPE is applicable in acetate buffer supporting electrolyte in the working potential close to − 0.30 V versus SCE and from + 0.70 to + 1.0 V; in the phosphate buffer solution only from + 0.60 V versus SCE and higher values. Due to the presence of the signal enhancement effect of Au and Ag nanoparticles, the sensitivity of the obtained methods is significantly higher in comparison to the results obtained by the MWCNT/CPE and bare CPE. The relative standard deviation of the measurements was lower than 10%. The practical application using the Ag-MWCNT/CPE was shown for the determination of H2O2 in real nursing product sample. It was proven that the developed mediator based (electro)catalytic platform exhibits low detection limit, high selectivity, reproducibility and stability.
引用
收藏
页码:1350 / 1361
页数:11
相关论文
共 50 条
  • [11] Carbon dots-decorated multiwalled carbon nanotubes nanocomposites as a high-performance electrochemical sensor for detection of H2O2 in living cells
    Bai, Jing
    Sun, Chunhe
    Jiang, Xiue
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (17) : 4705 - 4714
  • [12] Carbon dots-decorated multiwalled carbon nanotubes nanocomposites as a high-performance electrochemical sensor for detection of H2O2 in living cells
    Jing Bai
    Chunhe Sun
    Xiue Jiang
    Analytical and Bioanalytical Chemistry, 2016, 408 : 4705 - 4714
  • [13] Fabrication of a sensitive amperometric sensor for NADH and H2O2 using palladium nanoparticles-multiwalled carbon nanotube nanohybrid
    Hamidi, Hassan
    Haghighi, Behzad
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 62 : 423 - 428
  • [14] Electrodes modified with multiwalled carbon nanotubes carrying Fe3O4 beads: High sensitivity to H2O2
    Kang, Shi-Zhao
    Chen, Hong
    Mu, Jin
    SOLID STATE SCIENCES, 2011, 13 (01) : 142 - 145
  • [15] Amperometric Biosensor Based on Coimmobilization of Multiwalled Carbon Nanotubes and Horseradish Peroxidase-Gold Nanocluster Bioconjugates for Detecting H2O2
    Ren, Qiong-Qiong
    Yang, Fen
    Ren, Wu
    Wang, Chang
    Jiang, Wen-Shuai
    Zhao, Zong-Ya
    Chen, Jun
    Lu, Xuan-Yi
    Yu, Yi
    JOURNAL OF NANOMATERIALS, 2020, 2020
  • [16] Multiwalled carbon nanotubes oxidized by UV/H2O2 as catalyst for oxidative dehydrogenation of ethylbenzene
    Qui, N. V.
    Scholz, P.
    Krech, T.
    Keller, T. F.
    Pollok, K.
    Ondruschka, B.
    CATALYSIS COMMUNICATIONS, 2011, 12 (06) : 464 - 469
  • [17] Composite Electrodes With Carbon Supported Ru Nanoparticles For H2O2 Detection
    Januzaj, Valdrin
    Mula, Vllaznim
    Turdean, Graziella L.
    Muresan, Liana Maria
    ACTA CHIMICA SLOVENICA, 2015, 62 (01) : 28 - 34
  • [18] Electrospinning Synthesis of Ag Nanoparticles-doped Carbon Nanofibers for Voltammetric Determination of H2O2
    Zhu, Yanqiong
    Miao, Qinglan
    Han, Baosan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (02): : 1 - 11
  • [19] In situ growth of CuS decorated graphene oxide-multiwalled carbon nanotubes for ultrasensitive H2O2 detection in alkaline solution
    Jin, Wei
    Fu, Yanqiu
    Cai, Weiquan
    NEW JOURNAL OF CHEMISTRY, 2019, 43 (08) : 3309 - 3316
  • [20] Glassy carbon electrodes modified with hemin-carbon nanomaterial films for amperometric H2O2 and NO2- detection
    Valentini, Federica
    Cristofanelli, Lara
    Carbone, Marilena
    Palleschi, Giuseppe
    ELECTROCHIMICA ACTA, 2012, 63 : 37 - 46