Effects of dose rate on early and late complications in low dose rate brachytherapy for mobile tongue carcinoma using 192Ir sources

被引:0
|
作者
Atsushi Kaida
Hiroshi Watanabe
Kazuma Toda
Keiko Yuasa-Nakagawa
Ryoichi Yoshimura
Masahiko Miura
机构
[1] Tokyo Medical and Dental University,Department of Oral Radiation Oncology, Division of Oral Health Science, Graduate School of Medical and Dental Sciences
[2] Tokyo Medical and Dental University,Department of Oral and Maxillofacial Radiology, Division of Oral Health Science, Graduate School of Medical and Dental Sciences
[3] Tokyo Medical and Dental University,Department of Radiation Therapeutics and Oncology, Division of Maxillofacial and Neck Reconstruction, Graduate School of Medical and Dental Sciences
来源
Oral Radiology | 2017年 / 33卷
关键词
Low dose rate brachytherapy; Dose rate; Early complication; Late complication;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:187 / 192
页数:5
相关论文
共 50 条
  • [41] Dosimetry Parameters of the IRH10 192Ir High Dose Rate Brachytherapy Source
    Yi, Chul-Young
    Chun, Kook Jin
    Hah, Suck-Ho
    Kim, Hyun-Moon
    Lim, Chunil
    JOURNAL OF RADIATION RESEARCH, 2010, 51 (04) : 485 - 492
  • [42] A comparison of the expected costs of high dose rate brachytherapy using 252Cf versus 192Ir
    Rivard, MJ
    Kirk, BL
    Stapleford, LJ
    Wazer, DE
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (06) : 1211 - 1216
  • [43] High dose rate versus low dose rate brachytherapy in the treatment of tongue carcinoma - a radiobiological study
    Petera, J.
    Matula, P.
    Paluska, P.
    Sirak, I.
    Macingova, Z.
    Kasaova, L.
    Frgala, T.
    Hodek, M.
    Vosmik, M.
    NEOPLASMA, 2009, 56 (02) : 163 - 168
  • [44] Assessment of dose uniformity around high dose rate 192Ir and 60Co stepping sources
    Farhood B.
    Ghorbani M.
    Radiological Physics and Technology, 2017, 10 (4) : 454 - 463
  • [45] Determination of Dose at the Reference Point for 192Ir HDR Brachytherapy Sources Using Fricke Dosimetry
    Austerlitz, Carlos
    Benhabib, Sidi
    Zhu, Dengsong
    Mota, Helvecio
    Campos, Diana
    Allison, Ron
    Sibina, Claudio
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2008, 31 (06): : 617 - 617
  • [46] A Monte Carlo investigation of the dosimetric characteristics of the VariSource 192Ir high dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Sandilos, P
    Dardoufas, K
    Vlachos, L
    MEDICAL PHYSICS, 1999, 26 (08) : 1498 - 1502
  • [47] Feasibility of aponeurectomy in combination with perioperative 192Ir high dose rate brachytherapy for Dupuytren's disease
    Ciernik, I. Frank
    Goldschmidt, Philipp
    Woesle, Markus
    Winter, Jochen
    STRAHLENTHERAPIE UND ONKOLOGIE, 2021, 197 (10) : 903 - 908
  • [48] A system for localization of high dose rate 192Ir source during brachytherapy treatment with silicon detectors
    Batic, Matej
    Burger, Janez
    Cindro, Vladimir
    Kramberger, Gregor
    Mandic, Igor
    Mikuz, Marko
    Studen, Andrej
    Zavrtanik, Marko
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3794 - +
  • [49] Clinical application of 192Ir High-Dose-Rate brachytherapy in metastatic lymph nodes of the neck
    Lu, Hongling
    Sun, Yunchuan
    Gao, Yan
    Xiao, Li
    Zhou, Jianxi
    Yin, Xiaoming
    Guo, Wei
    Fan, Kui
    DISCOVER ONCOLOGY, 2023, 14 (01)
  • [50] Feasibility of aponeurectomy in combination with perioperative 192Ir high dose rate brachytherapy for Dupuytren’s disease
    I. Frank Ciernik
    Philipp Goldschmidt
    Markus Wösle
    Jochen Winter
    Strahlentherapie und Onkologie, 2021, 197 : 903 - 908