Effects of dose rate on early and late complications in low dose rate brachytherapy for mobile tongue carcinoma using 192Ir sources

被引:0
|
作者
Atsushi Kaida
Hiroshi Watanabe
Kazuma Toda
Keiko Yuasa-Nakagawa
Ryoichi Yoshimura
Masahiko Miura
机构
[1] Tokyo Medical and Dental University,Department of Oral Radiation Oncology, Division of Oral Health Science, Graduate School of Medical and Dental Sciences
[2] Tokyo Medical and Dental University,Department of Oral and Maxillofacial Radiology, Division of Oral Health Science, Graduate School of Medical and Dental Sciences
[3] Tokyo Medical and Dental University,Department of Radiation Therapeutics and Oncology, Division of Maxillofacial and Neck Reconstruction, Graduate School of Medical and Dental Sciences
来源
Oral Radiology | 2017年 / 33卷
关键词
Low dose rate brachytherapy; Dose rate; Early complication; Late complication;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:187 / 192
页数:5
相关论文
共 50 条
  • [21] Dosimetric characteristics of the 192Ir high-dose-rate afterloading brachytherapy source
    Sadeghi, Mahdi
    Taghdiri, Fatemah
    Saidi, Pooneh
    JAPANESE JOURNAL OF RADIOLOGY, 2011, 29 (05) : 324 - 329
  • [22] Dosimetric characteristics of the 192Ir high-dose-rate afterloading brachytherapy source
    Mahdi Sadeghi
    Fatemah Taghdiri
    Pooneh Saidi
    Japanese Journal of Radiology, 2011, 29 : 324 - 329
  • [23] Comparative Analysis of 60Co and 192Ir Sources in High Dose Rate Brachytherapy for Cervical Cancer
    Wen, Aiping
    Wang, Xianliang
    Wang, Bingjie
    Yan, Chuanjun
    Luo, Jingyue
    Wang, Pei
    Li, Jie
    CANCERS, 2022, 14 (19)
  • [24] A practical implementation of the 2010 IPEM high dose rate brachytherapy code of practice for the calibration of 192Ir sources
    Awunor, O. A.
    Lecomber, A. R.
    Richmond, N.
    Walker, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16): : 5397 - 5410
  • [25] Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source
    Sarabiasl, Akbar
    Ayoobian, Navid
    Jabbari, Iraj
    Poorbaygi, Hossein
    Javanshir, Mohammad Reza
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (02) : 413 - 422
  • [26] Small dimension plastic dosimeter in High Dose Rate Brachytherapy with 192Ir source
    Rego, Florbela
    Ribeiro, Tiago Ramos
    Peralta, Luis
    Jesus, Carlos
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 249 - 252
  • [27] Monte Carlo dosimetry of a new 192Ir high dose rate brachytherapy source
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Karaiskos, P
    Sandilos, P
    MEDICAL PHYSICS, 2000, 27 (11) : 2521 - 2527
  • [28] Patient effective dose from endovascular brachytherapy with 192Ir sources
    Perna, L
    Bianchi, C
    Nicolini, G
    Novario, R
    Tanzi, F
    Conte, L
    RADIATION PROTECTION DOSIMETRY, 2002, 102 (02) : 121 - 128
  • [29] Monte Carlo dosimetry of a new 192Ir pulsed dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Pantelis, E
    Papagiannis, P
    Sakelliou, L
    Kouwenhoven, E
    Baltas, D
    MEDICAL PHYSICS, 2003, 30 (01) : 9 - 16
  • [30] Verification of high dose rate 192Ir source position during brachytherapy treatment
    Batic, M.
    Burger, J.
    Cindro, V.
    Kramberger, G.
    Mandic, I.
    Mikuz, M.
    Studen, A.
    Zavrtanik, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 206 - 208