ANN approach for irreversibility analysis of vapor compression refrigeration system using R134a/LPG blend as replacement of R134a

被引:0
|
作者
Jatinder Gill
Jagdev Singh
Olayinka S. Ohunakin
Damola S. Adelekan
机构
[1] IKGPTU,Department of Mechanical Engineering
[2] BCET Gurdaspur,Faculty of Mechanical Engineering Department
[3] Covenant University,The Energy and Environment Research Group (TEERG), Mechanical Engineering Department
关键词
R134a/LPG; ANN; Total irreversibility; Irreversibility in VCRS components; Second law efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
This paper experimentally evaluated the irreversibility in the components (compressor, condenser, capillary tube, and evaporator) of the vapor compression refrigeration system (VCRS) using R134a/LPG refrigerant as a replacement for R134a. For this aim, different tests were conducted for various evaporator and condenser temperatures under controlled surrounding conditions. The results reported that the irreversibilities in the components of VCRS using R134a/LPG blend were found lesser than irreversibilities in the components of VCRS using R134a under similar experimental conditions. Artificial neural network (ANN) models were developed to predict the second law of efficiency and total irreversibility of the refrigeration system. ANN and ANFIS model predictions were also compared with experimental results and an absolute fraction of variance in range of 0.980–0.994 and 0.951–0.977, root-mean-square error in the range of 0.1636–0.2387 and 0.2501–0.4542 and mean absolute percentage error in the range of 0.159–0.572 and 0.308–0.931%, respectively, were estimated. The outcomes suggested that ANN model shows better statistical prediction than ANFIS model.
引用
收藏
页码:2495 / 2511
页数:16
相关论文
共 50 条
  • [41] Study of a solar booster assisted ejector refrigeration system with R134a
    Hernández, JI
    Best, R
    Dorantes, RJ
    Estrada, CA
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (01): : 53 - 59
  • [42] Energy evaluation of R152a as drop in replacement for R134a in cascade refrigeration plants
    Cabello, R.
    Sanchez, D.
    Llopis, R.
    Catalan, J.
    Nebot-Andres, L.
    Torrella, E.
    [J]. APPLIED THERMAL ENGINEERING, 2017, 110 : 972 - 984
  • [43] Refrigerant R513A as a Replacement for R134a in Chillers
    Schultz, Kenneth
    Kujak, Steve
    Majurin, Julie
    [J]. 2016 ASHRAE WINTER CONFERENCE PAPERS, 2016,
  • [44] Artificial neural network approach for irreversibility performance analysis of domestic refrigerator by utilizing LPG with TiO2-lubricant as replacement of R134a
    Gill, Jatinder
    Singh, Jagdev
    Ohunakin, Olayinka S.
    Adelekan, Damola S.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 89 : 159 - 176
  • [45] Energy and exergy analysis of R1234yf using instead of R134a in a vapour compression refrigeration system: an experimental study
    Bilen, Kemal
    Dagidir, Kayhan
    Arcaklioglu, Erol
    Cansevdi, Bekir
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2023, 42 (03) : 315 - 336
  • [46] Theoretical analysis of R1234yf and R1234yf/R125 mixture as replacement of R134a in vapor compression system
    Lin, Yongmei
    Meng, Zhaofeng
    Huo, Ziheng
    Ding, Chuangchuang
    Wang, Song
    Wang, Longji
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2024, 19 : 490 - 496
  • [47] Performance of low GWP R1234yf/R134a mixture as a replacement for R134a in automotive air conditioning systems
    Meng, Zhaofeng
    Zhang, Hua
    Lei, Mingjing
    Qin, Yanbin
    Qiu, Jinyou
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 116 : 362 - 370
  • [48] Modelling of Refrigerant Distribution in an Oil-Free Refrigeration System using R134a
    Chen, Xinwen
    Li, Zhaohua
    Zhao, Yi
    Jiang, Hanying
    Liang, Kun
    Chen, Jingxin
    [J]. ENERGIES, 2019, 12 (24)
  • [49] Experimental influence of an internal heat exchanger (IHX) using R513A and R134a in a vapor compression system
    Mota-Babiloni, Adrian
    Navarro-Esbri, Joaquin
    Pascual-Miralles, Victor
    Barragan-Cervera, Angel
    Maiorino, Angelo
    [J]. APPLIED THERMAL ENGINEERING, 2019, 147 : 482 - 491
  • [50] Exergy analysis and optimization of R600a as a replacement of R134a in a domestic refrigerator system
    Joybari, Mahmood Mastani
    Hatamipour, Mohammad Sadegh
    Rahimi, Amir
    Modarres, Fatemeh Ghadiri
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (04): : 1233 - 1242