Clinical usefulness of temporal subtraction method in screening digital chest radiography with a mobile computed radiography system

被引:5
|
作者
Sasaki Y. [1 ]
Abe K. [2 ]
Tabei M. [3 ]
Katsuragawa S. [4 ]
Kurosaki A. [5 ]
Matsuoka S. [1 ]
机构
[1] Department of Radiology, Iwate Prefectural Central Hospital, Morioka 020-0066
[2] Department of Radiology, School of Medicine, Nihon University, Itabashi-Ku, Tokyo 173-8610
[3] Medical Systems Business Division, FUJIFILM Medical, Minato-Ku, Tokyo 106-8620
[4] Department of Medical Physics, School of Health Sciences, Kumamoto University, Kumamoto 862-0976
[5] Department of Radiology, Toranomon Hospital, Minato-Ku, Tokyo 105-8470
关键词
Computed radiography; Digital radiography; Lung cancer screening; ROC analysis; Temporal subtraction image;
D O I
10.1007/s12194-010-0109-7
中图分类号
学科分类号
摘要
The temporal subtraction image which is obtained by subtraction of a previous image from a current image of the same patient can enhance interval changes. In this study, we applied the temporal subtraction method for lung cancer screening and evaluated the clinical usefulness by comparing the review time and the detection accuracy of lung cancers without and with subtraction images. Since 1996, we have been performing screening chest radiography for a mass survey of lung cancers in the Iwate Prefecture, Japan, by using a van equipped with a computed radiography system and a digital archive system. During the 12 years from 1997 to 2008, a total of 186,340 examinations were performed, and 121,526 (65.2%) temporal subtraction images were provided in the lung cancer screening. Twenty-four abnormal cases with lung cancer and 270 normal cases were selected from the lung cancer screening. Five radiologists participated in an observer performance study and interpreted previous and current chest radiographs without and with temporal subtraction images. In addition, radiologists interpreted previous and current images with a double-reading method. The average ROC curves demonstrated a significant improvement in the detection accuracy of lung cancers with the temporal subtraction images compared with that without the temporal subtraction images, and that with the double-reading method. Therefore, we believe strongly that the temporal subtraction method is clinically useful for radiologists in the detection of lung cancers in mass surveys. © 2010 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:84 / 90
页数:6
相关论文
共 50 条
  • [31] CLINICAL USEFULNESS OF DIGITAL RADIOGRAPHY IN THE GASTROINTESTINAL-TRACT - EFFICACY OF MAGNIFICATION METHOD
    SUGINO, Y
    IMAI, Y
    FUJISAWA, H
    HIRAMATSU, K
    AMOH, H
    KUMAKURA, K
    JOURNAL OF DIGITAL IMAGING, 1995, 8 (01) : 84 - 88
  • [33] Effect of temporal subtraction technique on interpretation time and diagnostic accuracy of chest radiography
    Kakeda, Shingo
    Kamada, Koji
    Hatakeyama, Yoshihisa
    Aoki, Takatoshi
    Korogi, Yukunori
    Katsuragawa, Shigehiko
    Doi, Kunio
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (05) : 1253 - 1259
  • [34] Screening for aortic injury with chest radiography and clinical factors
    Kirkham J.R.
    Blackmore C.C.
    Emergency Radiology, 2007, 14 (4) : 211 - 217
  • [35] Productivity and cost assessment of computed radiography, digital radiography, and screen-film for outpatient chest examinations
    Andriole, KP
    JOURNAL OF DIGITAL IMAGING, 2002, 15 (03) : 161 - 169
  • [36] Productivity and Cost Assessment of Computed Radiography, Digital Radiography, and Screen-Film for Outpatient Chest Examinations
    Katherine P. Andriole
    Journal of Digital Imaging, 2002, 15 : 161 - 169
  • [37] Clinical usefulness of temporal subtraction technique for detection of interval changes on digital chest radiographs
    Katsuragawa, S
    Uozumi, T
    Kakeda, S
    Watanabe, H
    Nakata, H
    Doi, K
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 689 - 694
  • [38] A flat-panel detector digital radiography and a storage phosphor computed radiography: Screening for pneumoconioses
    Takashima, Yoshihiro
    Suganuma, Narufumi
    Sakurazawa, Hirofumi
    Itoh, Harumi
    Hirano, Harukazu
    Shida, Hisao
    Kusaka, Yukinori
    JOURNAL OF OCCUPATIONAL HEALTH, 2007, 49 (01) : 39 - 45
  • [39] A ROBUST DIGITAL METHOD FOR FILM CONTRAST CORRECTION IN SUBTRACTION RADIOGRAPHY
    RUTTIMANN, UE
    WEBBER, RL
    SCHMIDT, E
    JOURNAL OF PERIODONTAL RESEARCH, 1986, 21 (05) : 486 - 495
  • [40] An implant-oriented method for dental digital subtraction radiography
    Börlin, N
    Lindh, T
    COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, : 705 - 712