Clinical usefulness of temporal subtraction method in screening digital chest radiography with a mobile computed radiography system

被引:5
|
作者
Sasaki Y. [1 ]
Abe K. [2 ]
Tabei M. [3 ]
Katsuragawa S. [4 ]
Kurosaki A. [5 ]
Matsuoka S. [1 ]
机构
[1] Department of Radiology, Iwate Prefectural Central Hospital, Morioka 020-0066
[2] Department of Radiology, School of Medicine, Nihon University, Itabashi-Ku, Tokyo 173-8610
[3] Medical Systems Business Division, FUJIFILM Medical, Minato-Ku, Tokyo 106-8620
[4] Department of Medical Physics, School of Health Sciences, Kumamoto University, Kumamoto 862-0976
[5] Department of Radiology, Toranomon Hospital, Minato-Ku, Tokyo 105-8470
关键词
Computed radiography; Digital radiography; Lung cancer screening; ROC analysis; Temporal subtraction image;
D O I
10.1007/s12194-010-0109-7
中图分类号
学科分类号
摘要
The temporal subtraction image which is obtained by subtraction of a previous image from a current image of the same patient can enhance interval changes. In this study, we applied the temporal subtraction method for lung cancer screening and evaluated the clinical usefulness by comparing the review time and the detection accuracy of lung cancers without and with subtraction images. Since 1996, we have been performing screening chest radiography for a mass survey of lung cancers in the Iwate Prefecture, Japan, by using a van equipped with a computed radiography system and a digital archive system. During the 12 years from 1997 to 2008, a total of 186,340 examinations were performed, and 121,526 (65.2%) temporal subtraction images were provided in the lung cancer screening. Twenty-four abnormal cases with lung cancer and 270 normal cases were selected from the lung cancer screening. Five radiologists participated in an observer performance study and interpreted previous and current chest radiographs without and with temporal subtraction images. In addition, radiologists interpreted previous and current images with a double-reading method. The average ROC curves demonstrated a significant improvement in the detection accuracy of lung cancers with the temporal subtraction images compared with that without the temporal subtraction images, and that with the double-reading method. Therefore, we believe strongly that the temporal subtraction method is clinically useful for radiologists in the detection of lung cancers in mass surveys. © 2010 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:84 / 90
页数:6
相关论文
共 50 条
  • [21] Application of temporally subtracted images with mobile computed radiography system in chest radiographs
    Sasaki, Y
    Katsuragawa, S
    MacMahon, H
    Doi, K
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 21 - 24
  • [22] Temporal subtraction in chest radiography: Mutual information as a measure of image quality
    Armato, Samuel G., III
    Sensakovic, William F.
    Passen, Samantha J.
    Engelmann, Roger
    MacMahon, Heber
    MEDICAL PHYSICS, 2009, 36 (12) : 5675 - 5682
  • [23] A CONTRAST-CORRECTION METHOD FOR DIGITAL SUBTRACTION RADIOGRAPHY
    OHKI, M
    OKANO, T
    YAMADA, N
    JOURNAL OF PERIODONTAL RESEARCH, 1988, 23 (04) : 277 - 280
  • [24] VARIABLE COMPENSATION CHEST RADIOGRAPHY PERFORMED WITH A COMPUTED RADIOGRAPHY SYSTEM - DESIGN CONSIDERATIONS AND INITIAL CLINICAL-EXPERIENCE
    DOBBINS, JT
    RICE, JJ
    GOODMAN, PC
    PATZ, EF
    RAVIN, CE
    RADIOLOGY, 1993, 187 (01) : 55 - 63
  • [25] A Mutual-Information-Based Global Matching Method for Chest-Radiography Temporal Subtraction
    Yu, Qian
    He, Lifeng
    Nakamura, Tsuyoshi
    Chao, Yuyan
    Suzuki, Kenji
    JOURNAL OF ADVANCED COMPUTATIONAL INTELLIGENCE AND INTELLIGENT INFORMATICS, 2012, 16 (07) : 841 - 850
  • [26] Clinical evaluation of a dual-side readout technique computed radiography system in chest radiography of premature neonates
    Carlander, A.
    Hansson, J.
    Soderberg, J.
    Steneryd, K.
    Bath, M.
    ACTA RADIOLOGICA, 2008, 49 (04) : 468 - 474
  • [27] Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography
    Takeshita, Wilton Mitsunari
    Vessoni Iwaki, Lilian Cristina
    Da Silva, Marillani Cicarelli
    Iwaki Filho, Liogi
    Queiroz, Alfredo De Franco
    Gomes Geron, Lucas Bacfiegas
    CONTEMPORARY CLINICAL DENTISTRY, 2013, 4 (03) : 338 - 342
  • [28] Quality and dose optimization in canine chest radiography using a digital radiography system
    Santana de Souza, Sergio Augusto
    Fattori Alves, Allan Felipe
    Mamprim, Maria Jaqueline
    Pina, Diana Rodrigues
    RADIATION PHYSICS AND CHEMISTRY, 2022, 195
  • [29] DIGITAL RADIOGRAPHY OF THE CHEST USING A COMPUTED-TOMOGRAPHY INSTRUMENT
    FOLEY, WD
    LAWSON, TL
    SCANLON, GT
    HEESCHEN, RC
    DIBIANCA, F
    RADIOLOGY, 1979, 133 (01) : 231 - 234
  • [30] Digital selenium radiography: anti-scatter grid for chest radiography in a clinical study
    Bernhardt, TM
    Rapp-Bernhardt, U
    Hausmann, T
    Reichel, G
    Krause, UW
    Doehring, W
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (873): : 963 - 968