Clinical usefulness of temporal subtraction method in screening digital chest radiography with a mobile computed radiography system

被引:5
|
作者
Sasaki Y. [1 ]
Abe K. [2 ]
Tabei M. [3 ]
Katsuragawa S. [4 ]
Kurosaki A. [5 ]
Matsuoka S. [1 ]
机构
[1] Department of Radiology, Iwate Prefectural Central Hospital, Morioka 020-0066
[2] Department of Radiology, School of Medicine, Nihon University, Itabashi-Ku, Tokyo 173-8610
[3] Medical Systems Business Division, FUJIFILM Medical, Minato-Ku, Tokyo 106-8620
[4] Department of Medical Physics, School of Health Sciences, Kumamoto University, Kumamoto 862-0976
[5] Department of Radiology, Toranomon Hospital, Minato-Ku, Tokyo 105-8470
关键词
Computed radiography; Digital radiography; Lung cancer screening; ROC analysis; Temporal subtraction image;
D O I
10.1007/s12194-010-0109-7
中图分类号
学科分类号
摘要
The temporal subtraction image which is obtained by subtraction of a previous image from a current image of the same patient can enhance interval changes. In this study, we applied the temporal subtraction method for lung cancer screening and evaluated the clinical usefulness by comparing the review time and the detection accuracy of lung cancers without and with subtraction images. Since 1996, we have been performing screening chest radiography for a mass survey of lung cancers in the Iwate Prefecture, Japan, by using a van equipped with a computed radiography system and a digital archive system. During the 12 years from 1997 to 2008, a total of 186,340 examinations were performed, and 121,526 (65.2%) temporal subtraction images were provided in the lung cancer screening. Twenty-four abnormal cases with lung cancer and 270 normal cases were selected from the lung cancer screening. Five radiologists participated in an observer performance study and interpreted previous and current chest radiographs without and with temporal subtraction images. In addition, radiologists interpreted previous and current images with a double-reading method. The average ROC curves demonstrated a significant improvement in the detection accuracy of lung cancers with the temporal subtraction images compared with that without the temporal subtraction images, and that with the double-reading method. Therefore, we believe strongly that the temporal subtraction method is clinically useful for radiologists in the detection of lung cancers in mass surveys. © 2010 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:84 / 90
页数:6
相关论文
共 50 条
  • [1] Application of temporal subtraction to screening chest radiographs with a mobile computed radiography system
    Katsuragawa, S
    Sasaki, Y
    MacMahon, H
    Ishida, T
    Doi, K
    COMPUTER-AIDED DIAGNOSIS IN MEDICAL IMAGING, 1999, 1182 : 51 - 56
  • [2] Usefulness of temporal subtraction images of chest computed radiography in routine clinical use: A prospective study
    Watanabe, H
    Okazaki, H
    Nakamura, K
    Nakata, H
    Katsuragawa, S
    Doi, K
    RADIOLOGY, 2001, 221 : 208 - 208
  • [3] Temporal subtraction chest radiography
    MacMahon, Heber
    Armato, Samuel G., III
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (02) : 238 - 243
  • [4] TEMPORAL SUBTRACTION CHEST RADIOGRAPHY
    LEVY, JM
    HESSEL, SJ
    CROWE, JK
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 140 (04) : 823 - 824
  • [5] Dual energy subtraction and temporal subtraction chest radiography
    MacMahon, Heber
    Li, Feng
    Engelmann, Roger
    Roberts, Rachael
    Armato, Samuel
    JOURNAL OF THORACIC IMAGING, 2008, 23 (02) : 77 - 85
  • [6] A method to optimize the processing algorithm of a computed radiography system for chest radiography
    Moore, C. S.
    Liney, G. P.
    Beavis, A. W.
    Saunderson, J. R.
    BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (957): : 724 - 730
  • [7] Digital chest radiography: Effect of temporal subtraction images on detection accuracy
    Difazio, MC
    MacMahon, H
    Xu, XW
    Tsai, P
    Shiraishi, J
    Armato, SG
    Doi, K
    RADIOLOGY, 1997, 202 (02) : 447 - 452
  • [8] Dual energy chest and temporal subtraction radiography
    MacMahon, H
    MEDICAL PHYSICS, 2003, 30 (06) : 1369 - 1369
  • [9] Evaluation of the clinical utility of temporal subtraction using bone suppression processing in digital chest radiography
    Takaki, Takeshi
    Murakami, Seiichi
    Tani, Natsumi
    Aoki, Takatoshi
    HELIYON, 2023, 9 (01)
  • [10] Clinical usefulness of temporal subtraction on digital chest radiographs
    Nakata, H
    Nakamura, K
    Uozumi, T
    Watanabe, H
    Aoki, T
    Katsuragawa, S
    Doi, K
    CARS 2000: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2000, 1214 : 793 - 797