Non-invasive estimation of jugular venous oxygen saturation: a comparison between near infrared spectroscopy and transcutaneous venous oximetry

被引:0
|
作者
Douglas A. Colquhoun
Jason M. Tucker-Schwartz
Marcel E. Durieux
Robert H. Thiele
机构
[1] University of Virginia,Department of Anesthesiology, Health Sciences Center
[2] Vanderbilt University,Department of Biomedical Engineering
关键词
NIRS; Plethysmyography; Central venous saturation;
D O I
暂无
中图分类号
学科分类号
摘要
The ability of practitioners to assess the adequacy of global oxygen delivery is dependent on an accurate measurement of central venous saturation. Traditional techniques require the placement of invasive central venous access devices. This study aimed to compare two non-invasive technologies for the estimation of regional venous saturation (reflectance plethysmography and near infrared spectroscopy [NIRS]), using venous blood gas analysis as gold standard. Forty patients undergoing cardiac surgery were recruited in two groups. In the first group a reflectance pulse oximeter probe was placed on the skin overlying the internal jugular vein. In the second group, a Somanetics INVOS oximeter patch was placed on the skin overlying the internal jugular vein and overlying the ipsilateral cerebral hemisphere. Central venous catheters were placed in all patients. Oxygen saturation estimates from both groups were compared with measured saturation from venous blood. Twenty patients participated in each group. Data were analyzed by the limits of agreement technique suggested by Bland and Altman and by linear regression analysis. In the reflectance plethysmography group, the mean bias was 4.27% and the limits of agreement were 58.3 to −49.8% (r2 = 0.00, p = 0.98). In the NIRS group the mean biases were 10.8% and 2.0% for the sensors attached over the cerebral hemisphere and over the internal jugular vein, respectively, and the limits of agreement were 33.1 to −11.4 and 19.5 to −15.5% (r2 = 0.22, 0.28; p = 0.04, 0.03) for the cerebral hemisphere and internal jugular sites, respectively. While transcutaneous regional oximetry and NIRS have both been used to estimate venous and tissue oxygen saturation non-invasively, the correlation between estimates of ScvO2 and SxvO2 were statistically significant for near infrared spectroscopy, but not for transcutaneous regional oximetry. Placement of cerebral oximetry patches directly over the internal jugular vein (as opposed to on the forehead) appeared to approximate internal jugular venous saturation better (lower mean bias and tighter limits of agreement), which suggests this modality may with refinement offer the practitioner additional clinically useful information regarding global cerebral oxygen supply and demand matching.
引用
收藏
页码:91 / 98
页数:7
相关论文
共 50 条
  • [1] Non-invasive estimation of jugular venous oxygen saturation: a comparison between near infrared spectroscopy and transcutaneous venous oximetry
    Colquhoun, Douglas A.
    Tucker-Schwartz, Jason M.
    Durieux, Marcel E.
    Thiele, Robert H.
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2012, 26 (02) : 91 - 98
  • [2] Local measurement of venous saturation in tissue with non-invasive, near-infrared respiratory-oximetry
    Franceschini, MA
    Zourabian, A
    Moore, JB
    Arora, A
    Fantini, S
    Boas, DA
    [J]. OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE IV, 2001, 4250 : 164 - 170
  • [3] Use of near infrared spectroscopy for estimation of peripheral venous saturation in newborns: Comparison with co-oximetry of central venous blood
    Bay-Hansen, R
    Elfving, B
    Greisen, G
    [J]. BIOLOGY OF THE NEONATE, 2002, 82 (01): : 1 - 8
  • [4] Comparison of regional transcranial oximetry with near infrared spectroscopy (NIRS) and jugular venous bulb oxygen saturation for the monitoring of cerebral oxygenation in infants and children
    Abdul-Khaliq, H
    Troitzsch, D
    Berger, F
    Lange, PE
    [J]. BIOMEDIZINISCHE TECHNIK, 2000, 45 (11): : 328 - 332
  • [5] NON-INVASIVE DETERMINATION OF CEREBRAL VENOUS HEMOGLOBIN SATURATION IN THE DOG BY NEAR-INFRARED SPECTROSCOPY
    FERRARI, M
    HARTMANN, JF
    HANLEY, DF
    WILSON, DA
    TRAYSTMAN, RJ
    [J]. FASEB JOURNAL, 1988, 2 (04): : A508 - A508
  • [6] The Accuracy of a Near-Infrared Spectroscopy Cerebral Oximetry Device and Its Potential Value for Estimating Jugular Venous Oxygen Saturation
    Ikeda, Keita
    MacLeod, David B.
    Grocott, Hilary P.
    Moretti, Eugene W.
    Ames, Warwick
    Vacchiano, Charles
    [J]. ANESTHESIA AND ANALGESIA, 2014, 119 (06): : 1381 - 1392
  • [7] Jugular venous bulb oxygen saturation compared with cerebral saturation measured by near infrared spectroscopy.
    OwenReece, H
    Smith, M
    Elwell, CE
    Lovell, AT
    Goldstone, J
    [J]. ANESTHESIA AND ANALGESIA, 1997, 84 : S370 - S370
  • [8] Pulse oximetry in the pulmonary tissue for the non-invasive measurement of mixed venous oxygen saturation
    Nitzan, Meir
    Nitzan, Itamar
    [J]. MEDICAL HYPOTHESES, 2013, 81 (02) : 293 - 296
  • [9] Proof of concept non-invasive estimation of peripheral venous oxygen saturation
    Musabbir Khan
    Chris G. Pretty
    Alexander C. Amies
    Joel Balmer
    Houda E. Banna
    Geoffrey M. Shaw
    J. Geoffrey Chase
    [J]. BioMedical Engineering OnLine, 16
  • [10] Proof of concept non-invasive estimation of peripheral venous oxygen saturation
    Khan, Musabbir
    Pretty, Chris G.
    Amies, Alexander C.
    Balmer, Joel
    Banna, Houda E.
    Shaw, Geoffrey M.
    Chase, J. Geoffrey
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2017, 16