The Accuracy of a Near-Infrared Spectroscopy Cerebral Oximetry Device and Its Potential Value for Estimating Jugular Venous Oxygen Saturation

被引:65
|
作者
Ikeda, Keita [1 ]
MacLeod, David B. [1 ]
Grocott, Hilary P. [2 ]
Moretti, Eugene W. [1 ]
Ames, Warwick [1 ]
Vacchiano, Charles [3 ]
机构
[1] Duke Univ, Med Ctr, Dept Anesthesiol, Durham, NC 27710 USA
[2] Univ Manitoba, Dept Anesthesia & Perioperat Med, Winnipeg, MB, Canada
[3] Duke Univ, Sch Nursing, Durham, NC USA
来源
ANESTHESIA AND ANALGESIA | 2014年 / 119卷 / 06期
关键词
BLOOD-FLOW; HEALTHY-VOLUNTEERS; ARTERIAL FRACTION; CARBON-DIOXIDE; VOLUME; DESATURATION; TOMOGRAPHY; METABOLISM; HYPOCAPNIA; THICKNESS;
D O I
10.1213/ANE.0000000000000463
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: An intriguing potential clinical use of cerebral oximeter measurements (SctO2) is the ability to noninvasively estimate jugular bulb venous oxygen saturation (SjvO2). Our purpose in this study was to determine the accuracy of the FORE-SIGHT (R) (CAS Medical Systems, Branford, CT), which is calibrated to a weighted average of 70% (SjvO2) and 30% arterial saturation, for Food and Drug Administration pre-market approval 510(k) certification by adapting an industry standard protocol, ISO 9919:2005 (www.ISO.org) (used for pulse oximeters), and to evaluate the use of SctO2 and SpO2 measurements to noninvasively estimate jugular venous oxygen saturation (SnvO2). METHODS: Paired blood gas samples from the radial artery and the jugular venous bulb were collected from 20 healthy volunteers undergoing progressive oxygen desaturation from 100% to 70%. The blood sample pairs were analyzed via co-oximetry and used to calculate the approximate mixed vascular cerebral blood oxygen saturation, or reference SctO2 values (refS(ct)O(2)), during increasing hypoxia. These reference values were compared to bilateral FORE-SIGHT SctO2 values recorded simultaneously with the blood gas draws to determine its accuracy. Bilateral SctO2 and SpO2 measurements were then used to calculate SnvO2 values which were compared to SjvO2. RESULTS: Two hundred forty-six arterial and 253 venous samples from 18 subjects were used in the analysis. The ipsilateral FORE-SIGHT SctO2 values showed a tolerance interval (TI) of [-10.72 to 10.90] and Lin concordance correlation coefficient (CCC) with standard error (SE) of 0.83 +/- 0.073 with the refS(ct)O(2) values calculated using arterial and venous blood gases. The ipsilateral data had a CCC of 0.81 + 0.059 with TI of [-9.22 to 9.40] with overall bias of 0.09%, and amplitude of the root mean square of error after it was corrected with random effects analysis was 2.92%. The bias and variability values between the ipsilateral and the contralateral FORE-SIGHT SctO2 measurements varied from person to person. The SnvO2 calculated from the ipsilateral SctO2 and SpO2 data showed a CCC +/- SE of 0.79 +/- 0.088, TI = [-14.93 to 15.33], slope of 0.98, y-intercept of 1.14% with SjvO2 values with a bias of 0.20% and an Arms of 4.08%. The SnvO2 values calculated independently from contralateral forehead FORE-SIGHT SctO2 values were not as correlated with the SjvO2 values (contralateral side CCC + SE = 0.72 +/- 0.118, TI = [-14.86 to 15.20], slope of 0.66, and y-intercept of 20.36%). CONCLUSIONS: The FORE-SIGHT cerebral oximeter was able to estimate oxygen saturation within the tissues of the frontal lobe under conditions of normocapnia and varying degrees of hypoxia (with 95% confidence interval of [-5.60 to 5.78] with ipsilateral blood sample data). These findings from healthy volunteers also suggest that the use of the calculated SnvO2 derived from SctO2 and SpO2 values may be a reasonable noninvasive method of estimating SjvO2 and therefore global cerebral oxygen consumption in the clinical setting. Further laboratory and clinical research is required to define the clinical utility of near-infrared spectroscopy determination of SctO2 and SnvO2 in the operating room setting.
引用
收藏
页码:1381 / 1392
页数:12
相关论文
共 50 条
  • [1] Cerebral oxygen saturation measured by near-infrared spectroscopy and jugular oxygen saturation
    Mellor A.
    [J]. Critical Care, 1 (1):
  • [2] Near-infrared spectroscopy cerebral and somatic (renal) oxygen saturation correlation to continuous venous oxygen saturation via intravenous oximetry catheter
    Marimon, Gilma A.
    Dockery, W. Keith
    Sheridan, Michael J.
    Agarwal, Swati
    [J]. JOURNAL OF CRITICAL CARE, 2012, 27 (03) : 314.e13 - 314.e18
  • [3] NEAR-INFRARED SPECTROSCOPY CEREBRAL AND SOMATIC (RENAL) OXYGEN SATURATION CORRELATION TO CONTINUOUS VENOUS OXYGEN SATURATION VIA INTRAVENOUS OXIMETRY CATHETER
    Marimon, Gilma
    Dockery, W.
    Sheridan, Michael
    Agarwal, Swati
    [J]. CRITICAL CARE MEDICINE, 2009, 37 (12) : A102 - A102
  • [4] Jugular venous bulb oxygen saturation compared with cerebral saturation measured by near infrared spectroscopy.
    OwenReece, H
    Smith, M
    Elwell, CE
    Lovell, AT
    Goldstone, J
    [J]. ANESTHESIA AND ANALGESIA, 1997, 84 : S370 - S370
  • [5] MEASUREMENT OF CEREBRAL VENOUS OXYHEMOGLOBIN SATURATION IN CHILDREN BY NEAR-INFRARED SPECTROSCOPY AND PARTIAL JUGULAR VENOUS OCCLUSION
    YOXALL, CW
    WEINDLING, AM
    DAWANI, NH
    PEART, I
    [J]. PEDIATRIC RESEARCH, 1995, 38 (03) : 319 - 323
  • [6] Noninvasive tracking of mixed venous oxygen saturation via near-infrared spectroscopy cerebral oximetry: a retrospective observational study
    Chahyun Oh
    Sujin Baek
    Soomin Lee
    Man-Shik Shim
    Sung Joon Han
    Yoon-Hee Kim
    Jeong Yeon Lee
    Yunseo Ku
    Boohwi Hong
    [J]. Scientific Reports, 13 (1)
  • [7] Noninvasive tracking of mixed venous oxygen saturation via near-infrared spectroscopy cerebral oximetry: a retrospective observational study
    Oh, Chahyun
    Baek, Sujin
    Lee, Soomin
    Shim, Man-Shik
    Han, Sung Joon
    Kim, Yoon-Hee
    Lee, Jeong Yeon
    Ku, Yunseo
    Hong, Boohwi
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01):
  • [8] Non-invasive estimation of jugular venous oxygen saturation: a comparison between near infrared spectroscopy and transcutaneous venous oximetry
    Colquhoun, Douglas A.
    Tucker-Schwartz, Jason M.
    Durieux, Marcel E.
    Thiele, Robert H.
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2012, 26 (02) : 91 - 98
  • [9] Non-invasive estimation of jugular venous oxygen saturation: a comparison between near infrared spectroscopy and transcutaneous venous oximetry
    Douglas A. Colquhoun
    Jason M. Tucker-Schwartz
    Marcel E. Durieux
    Robert H. Thiele
    [J]. Journal of Clinical Monitoring and Computing, 2012, 26 : 91 - 98
  • [10] Cerebral oxygenation measured by near-infrared spectroscopy: Comparison with jugular bulb oximetry
    Daubeney, PEF
    Pilkington, SN
    Janke, E
    Charlton, GA
    Smith, DC
    Webber, SA
    [J]. ANNALS OF THORACIC SURGERY, 1996, 61 (03): : 930 - 934