Near-infrared spectroscopy cerebral and somatic (renal) oxygen saturation correlation to continuous venous oxygen saturation via intravenous oximetry catheter

被引:36
|
作者
Marimon, Gilma A. [1 ]
Dockery, W. Keith [1 ]
Sheridan, Michael J. [2 ]
Agarwal, Swati [1 ]
机构
[1] Inova Fairfax Hosp Children, Dept Pediat, Falls Church, VA USA
[2] Inova Hlth Syst, Inova Res Ctr, Falls Church, VA USA
关键词
PediaSat; Near-infrared spectroscopy; Oximetry; Central venous oxygen saturation; Mixed venous oxygen saturation; CALCULATING CORRELATION-COEFFICIENTS; PEDIATRIC CARDIAC-SURGERY; CRITICALLY-ILL; SEPTIC SHOCK; CHILDREN; OUTCOMES;
D O I
10.1016/j.jcrc.2011.10.002
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: Near-infrared spectroscopy (NIRS) and continuous central venous oxygen saturation (ScvO(2)) via oximetry catheter are 2 modalities available to estimate adequacy of oxygen delivery in postoperative pediatric cardiac patients. Near-infrared spectroscopy measures regional tissue oxygenation and is routinely used in pediatric cardiac surgery patients. By not requiring an invasive catheter, NIRS has the advantage over mixed venous oxygen saturation (SvO(2)) monitoring. An alternative marker of global tissue oxygenation is central venous oxygen saturation (ScvO(2)). A recently developed pediatric-sized oximetric catheter (PediaSat; Edwards Lifesciences, Irvine, CA, USA) functions as a central venous catheter and provides a continuous ScvO(2) reading, an accepted surrogate to SvO2. To date, the correlation between NIRS and ScvO(2) has not been quantified. The aim of this study was to examine the strength of the bivariate correlation between NIRS and ScvO2 measurements. Design/methods: Twenty pediatric patients undergoing cardiac surgery had the PediaSat catheter placed with the tip in the superior vena cava and NIRS sensors (cerebral and renal) placed in the operating room per routine protocol. Hourly measurements of NIRS-cerebral (NIRS-C), NIRS-renal, and ScvO(2) readings were recorded for each patient for up to 48 hours postoperatively. Results: A cumulative total of 630 hours of data were collected. Spearman correlation coefficients for NIRS-renal vs ScvO(2) and NIRS-C vs ScvO(2) measurements were r = 0.38 (P = .09) and r = 0.58 (P < .008), respectively. Conclusions: In this small cohort of pediatric patients undergoing heart surgery, there was a moderate but statistically significant correlation between the ScvO(2)-catheter and the NIRS-C values. Further studies are required to determine which oxymetric modality of monitoring cardiac output most aids in the postoperative management of these patients. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:314.e13 / 314.e18
页数:6
相关论文
共 50 条
  • [1] NEAR-INFRARED SPECTROSCOPY CEREBRAL AND SOMATIC (RENAL) OXYGEN SATURATION CORRELATION TO CONTINUOUS VENOUS OXYGEN SATURATION VIA INTRAVENOUS OXIMETRY CATHETER
    Marimon, Gilma
    Dockery, W.
    Sheridan, Michael
    Agarwal, Swati
    [J]. CRITICAL CARE MEDICINE, 2009, 37 (12) : A102 - A102
  • [2] Cerebral oxygen saturation measured by near-infrared spectroscopy and jugular oxygen saturation
    Mellor A.
    [J]. Critical Care, 1 (1):
  • [3] Noninvasive tracking of mixed venous oxygen saturation via near-infrared spectroscopy cerebral oximetry: a retrospective observational study
    Chahyun Oh
    Sujin Baek
    Soomin Lee
    Man-Shik Shim
    Sung Joon Han
    Yoon-Hee Kim
    Jeong Yeon Lee
    Yunseo Ku
    Boohwi Hong
    [J]. Scientific Reports, 13 (1)
  • [4] Noninvasive tracking of mixed venous oxygen saturation via near-infrared spectroscopy cerebral oximetry: a retrospective observational study
    Oh, Chahyun
    Baek, Sujin
    Lee, Soomin
    Shim, Man-Shik
    Han, Sung Joon
    Kim, Yoon-Hee
    Lee, Jeong Yeon
    Ku, Yunseo
    Hong, Boohwi
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01):
  • [5] The Accuracy of a Near-Infrared Spectroscopy Cerebral Oximetry Device and Its Potential Value for Estimating Jugular Venous Oxygen Saturation
    Ikeda, Keita
    MacLeod, David B.
    Grocott, Hilary P.
    Moretti, Eugene W.
    Ames, Warwick
    Vacchiano, Charles
    [J]. ANESTHESIA AND ANALGESIA, 2014, 119 (06): : 1381 - 1392
  • [6] A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients
    Tortoriello, TA
    Stayer, SA
    Mott, AR
    McKenzie, ED
    Fraser, CD
    Andropoulos, DB
    Chang, AC
    [J]. PEDIATRIC ANESTHESIA, 2005, 15 (06) : 495 - 503
  • [7] Correlation between cerebral oxygen saturation measured by near-infrared spectroscopy and jugular oxygen saturation in patients with severe closed head injury
    Ter Minassian, A
    Poirier, N
    Pierrot, M
    Menei, P
    Granry, JC
    Ursino, M
    Beydon, L
    [J]. ANESTHESIOLOGY, 1999, 91 (04) : 985 - 990
  • [8] Correlation of brain tissue oxygen tension with cerebral near-infrared spectroscopy and mixed venous oxygen saturation during extracorporeal membrane oxygenation
    Tyree, Kreangkai
    Tyree, Melissa
    DiGeronimo, Robert
    [J]. PERFUSION-UK, 2009, 24 (05): : 325 - 331
  • [9] Jugular venous bulb oxygen saturation compared with cerebral saturation measured by near infrared spectroscopy.
    OwenReece, H
    Smith, M
    Elwell, CE
    Lovell, AT
    Goldstone, J
    [J]. ANESTHESIA AND ANALGESIA, 1997, 84 : S370 - S370
  • [10] Measurement of peripheral venous oxygen saturation in the leg using near-infrared spectroscopy
    Wertheim, D
    Salaman, R
    Melhuish, J
    Williams, R
    Lane, I
    Harding, K
    [J]. PHLEBOLOGY, 1997, 12 (03) : 96 - 99