Comparison of bicarbonate and base excess values analyzed by four different blood gas analyzers

被引:0
|
作者
Katsuhito Nakamaru
Noboru Hatakeyama
Masana Yamada
Mitsuaki Yamazaki
机构
[1] Toyama University Hospital,Department of Surgical Operation
来源
Journal of Anesthesia | 2007年 / 21卷
关键词
Blood gas analysis; Base excess; Bicarbonate;
D O I
暂无
中图分类号
学科分类号
摘要
Comparison of the calculation formula, reproducibility, correlation and variation of bicarbonate ion concentration (HCO3−), and base excess value (BE) among four blood-gas analyzers was performed. No HCO3− and BE values calculated from the formulas showed any clinically significant difference, and all analyzers showed good correlation on their measurements. On the actual measurement of a specific sample, however, BE values from the same sample ranged between −6.3 and −15.7, which might affect therapeutic strategy. Caution should be taken for the assessment of data if different types of blood-gas analysis devices are used in the same facility.
引用
收藏
相关论文
共 50 条
  • [31] Comparison of whole blood total bilirubin determination in neonates on the Siemens Rapidlab and radiometer ABL blood gas analyzers
    Dietzen, D. J.
    Wilhite, T. R.
    [J]. CLINICAL CHEMISTRY, 2008, 54 (06) : A235 - A235
  • [32] Comparison of 4 point-of-care blood gas analyzers for arterial blood gas analysis in healthy dogs and dogs with cardiopulmonary disease
    Roels, Elodie
    Gommeren, Kris
    Farnir, Frederic
    Delvaux, Francois
    Billen, Frederic
    Clercx, Cecile
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2016, 26 (03) : 352 - 359
  • [33] Three-year monitoring and comparison of results from two identical blood gas analyzers
    Huang, Yun
    Dean, Robert
    Dubbelman, Yvonne
    Vincent, Anne
    Chan, Ying-pui Michael
    [J]. PRACTICAL LABORATORY MEDICINE, 2022, 31
  • [34] Comparison of Lactate, Base Excess, Bicarbonate, and pH as Predictors of Mortality after Severe Trauma in Rhesus Macaques (Macaca mulatta)
    Hobbs, Theodore R.
    O'Malley, Jean P.
    Khouangsathiene, Samone
    Dubay, Christopher J.
    [J]. COMPARATIVE MEDICINE, 2010, 60 (03) : 233 - 239
  • [35] Three-year monitoring and comparison of results from two identical blood gas analyzers
    Huang, Yun
    Dean, Robert
    Dubbelman, Yvonne
    Vincent, Anne
    Chan, Ying-pui Michael
    [J]. PRACTICAL LABORATORY MEDICINE, 2022, 31
  • [36] COMPARISON OF SIEMENS 405 AND EPOC POINT-OF-CARE BLOOD GAS ANALYZERS WITH SIEMENS 865
    Van Even, Ellen
    Ghys, Tim
    De Puydt, Hendrik
    Louagie, Henk
    [J]. ACTA CLINICA BELGICA, 2012, 67 (01): : 61 - 61
  • [37] Pitfalls in Comparison of Exercise-Induced Changes of Base Excess and Lactate Concentrations in Blood
    Boning, Dieter
    Klarholz, Carola
    Himmelsbach, Barbel
    Hutler, Matthias
    Maassen, Norbert
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S88 - S88
  • [38] VALUES OF THE INDEXES OF THE ACID-BASE BLOOD HOMEOSTASIS IN SOWS OF DIFFERENT BREEDS
    BARTKO, P
    VRZGULA, L
    MICHNA, A
    [J]. VETERINARNI MEDICINA, 1980, 25 (07) : 385 - 390
  • [39] Changes in gas composition and acid-base values of venous blood samples stored at different temperatures in 4 domestic species
    Piccione, Giuseppe
    Bertolucci, Cristiano
    Grasso, Fortunata
    Giudice, Elisabetta
    [J]. VETERINARY CLINICAL PATHOLOGY, 2007, 36 (04) : 358 - 360
  • [40] Electrolyte measurement in goats: Comparison of 2 blood gas analyzers and evaluation of the preanalytical blood sample preparation on measurement results
    Luethy, Daniela
    Hopster, Klaus
    [J]. TIERAERZTLICHE PRAXIS AUSGABE GROSSTIERE NUTZTIERE, 2020, 48 (03): : 148 - 155