Three-year monitoring and comparison of results from two identical blood gas analyzers

被引:0
|
作者
Huang, Yun [1 ,2 ]
Dean, Robert [1 ]
Dubbelman, Yvonne [1 ]
Vincent, Anne [1 ]
Chan, Ying-pui Michael [2 ]
机构
[1] Kingston Hlth Sci Ctr, Clin Labs, 76 Stuart St, Kingston, ON, Canada
[2] Queens Univ, Dept Pathol & Mol Med, 76 Stuart St, Kingston, ON, Canada
关键词
Blood gas analyzer; Result interchangeability; Between-analyzer comparison; Point-of-care testing;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Measurement comparability between blood gas analyzers within a laboratory is of utmost importance. This study analyzed the data obtained from a three-year period. Design and methods: For quality monitoring one blood sample was tested on two identical blood gas analyzers at each of three shifts/day for three years. Deming regression analysis was used to determine result correlation and statistical identity between the two analyzers for pH, pCO(2), pO(2), sodium, potassium, chloride, ionized calcium, glucose, and lactate. Failures in the two-analyzer comparison were determined by the performance limits from the Institute of Quality Management in Healthcare (IQMH) and from the manufacturer respectively. Results: Correlation coefficients were greater than 0.96 (0.9622-0.9975) for all tested analytes. The measurements of every analyte on both analyzers were statistically identical. In the two-analyzer comparison failure numbers/1000 tests for pO(2) and glucose varied with the performance limits (IQMH: 0.6 and 49.2; the manufacturer: 19.3 and 4.4, respectively). In addition, persistent glucose failures (>5/week) between the two analyzers occurred occasionally. Conclusions: Results of all tested analytes between the two blood gas analyzers were interchangeable. Recurring glucose discrepancies might be a result of different lots of cartridges used on each analyzer, which were not identified during the initial installation.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Three-year monitoring and comparison of results from two identical blood gas analyzers
    Huang, Yun
    Dean, Robert
    Dubbelman, Yvonne
    Vincent, Anne
    Chan, Ying-pui Michael
    [J]. PRACTICAL LABORATORY MEDICINE, 2022, 31
  • [2] Pesticide Residues in Mandarins: Three-Year Monitoring Results
    Gormez, Emrah
    Golge, Ozgur
    Gonzalez-Curbelo, Miguel Angel
    Kabak, Bulent
    [J]. MOLECULES, 2023, 28 (14):
  • [3] Comparison of blood gas, electrolyte and metabolite results measured with two different blood gas analyzers and a core laboratory analyzer
    Uyanik, Metin
    Sertoglu, Erdim
    Kayadibi, Huseyin
    Tapan, Serkan
    Serdar, Muhittin A.
    Bilgi, Cumhur
    Kurt, Ismail
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2015, 75 (02): : 97 - 105
  • [4] Two- and three-year achievement results from the Memphis Restructuring Initiative
    Ross, SM
    Sanders, WL
    Wright, SP
    Stringfield, S
    Wang, LWP
    Alberg, M
    [J]. SCHOOL EFFECTIVENESS AND SCHOOL IMPROVEMENT, 2001, 12 (03) : 323 - 346
  • [5] Comparison of the bovine blood gas parameters produced with three types of portable blood gas analyzers
    Ro, Younghye
    Choi, Woojae
    Hong, Leegon
    Kim, Eunkyung
    Choe, Eunhui
    Kim, Danil
    [J]. JOURNAL OF VETERINARY SCIENCE, 2022, 23 (04)
  • [6] Three-year monitoring results of nitrate and ammonium wet deposition in thailand
    Paramee, S
    Chidthaisong, A
    Towprayoon, S
    Asnachinda, P
    Bashkin, VN
    Tangtham, N
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2005, 102 (1-3) : 27 - 40
  • [7] Three-year monitoring results of nitrate and ammonium wet deposition in Thailand
    Suparb Paramee
    Amnat Chidthaisong
    Sirintornthep Towprayoon
    Pongpor Asnachinda
    Vladimir N. Bashkin
    Nipon Tangtham
    [J]. Environmental Monitoring and Assessment, 2005, 102 : 27 - 40
  • [8] Three-year follow-up results of two children born from a transplanted uterus
    Janota, Jan
    Orlova, Ekaterina
    Novackova, Marta
    Chmel Jr, Roman
    Brabec, Radim
    Pastor, Zlatko
    Chmel, Roman
    [J]. BIOMEDICAL PAPERS-OLOMOUC, 2023, 167 (04): : 370 - 375
  • [9] Results From a Three-Year Transition to the Extreme Apprenticeship Method
    Vihavainen, Arto
    Luukkainen, Matti
    [J]. 2013 IEEE 13TH INTERNATIONAL CONFERENCE ON ADVANCED LEARNING TECHNOLOGIES (ICALT 2013), 2013, : 336 - 340
  • [10] Behaviour of retrogressive thaw slumps in northern Canada—three-year monitoring results from 18 sites
    Baolin Wang
    Bhuwani Paudel
    Haoqiang Li
    [J]. Landslides, 2016, 13 : 1 - 8