Comparison of the calculation formula, reproducibility, correlation and variation of bicarbonate ion concentration (HCO3−), and base excess value (BE) among four blood-gas analyzers was performed. No HCO3− and BE values calculated from the formulas showed any clinically significant difference, and all analyzers showed good correlation on their measurements. On the actual measurement of a specific sample, however, BE values from the same sample ranged between −6.3 and −15.7, which might affect therapeutic strategy. Caution should be taken for the assessment of data if different types of blood-gas analysis devices are used in the same facility.
引用
收藏
相关论文
共 50 条
  • [1] Comparison of bicarbonate and base excess values analyzed by four different blood gas analyzers
    Nakamaru, Katsuhito
    Hatakeyama, Noboru
    Yamada, Masana
    Yamazaki, Mitsuaki
    [J]. JOURNAL OF ANESTHESIA, 2007, 21 (03) : 429 - 432
  • [2] A COMPARISON OF 4 DIFFERENT BLOOD-GAS ANALYZERS
    KOFSTAD, J
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1981, 41 (04): : 409 - 414
  • [3] Comparison of blood gas, electrolyte and metabolite results measured with two different blood gas analyzers and a core laboratory analyzer
    Uyanik, Metin
    Sertoglu, Erdim
    Kayadibi, Huseyin
    Tapan, Serkan
    Serdar, Muhittin A.
    Bilgi, Cumhur
    Kurt, Ismail
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2015, 75 (02): : 97 - 105
  • [4] Agreement between arterial and central venous values for pH, bicarbonate, base excess, and lactate
    Middleton, P.
    Kelly, A-M
    Brown, J.
    Robertson, M.
    [J]. EMERGENCY MEDICINE JOURNAL, 2006, 23 (08) : 622 - 624
  • [6] Comparison of the bovine blood gas parameters produced with three types of portable blood gas analyzers
    Ro, Younghye
    Choi, Woojae
    Hong, Leegon
    Kim, Eunkyung
    Choe, Eunhui
    Kim, Danil
    [J]. JOURNAL OF VETERINARY SCIENCE, 2022, 23 (04)
  • [7] Analytical performance evaluation of four cartridge-type blood gas analyzers
    De Koninck, Anne-Sophie
    De Decker, Koen
    Van Bocxlaer, Jan
    Meeus, Peter
    Van Hoovels, Lieve
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (06) : 1083 - 1091
  • [8] ANALYTICAL PERFORMANCE EVALUATION OF FOUR CARTRIDGE-TYPE BLOOD GAS ANALYZERS
    De Koninck, Anne-Sophie
    De Decker, Koen
    Beckers, Fabienne
    Van Bocxlaer, Jan
    Meeus, Peter
    Van Hoovels, Lieve
    [J]. ACTA CLINICA BELGICA, 2012, 67 (01): : 61 - 61
  • [9] Comparison of blood gas values in arterial and venous blood
    Chellam Kirubakaran
    J. Ebor Jacob Gnananayagam
    E. Kalaranjini Sundaravalli
    [J]. The Indian Journal of Pediatrics, 2003, 70 (10) : 781 - 785
  • [10] Comparison of nucleated red blood cell count with four commercial hematological analyzers
    Pipitone, Silvia
    Buonocore, Ruggero
    Gennari, Daniela
    Lippi, Giuseppe
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2015, 53 (11) : E315 - E318