Efficacy of scleral imbrication on all quadrants in enucleated pig eyes

被引:0
|
作者
Osamu Sawada
Shumpei Obata
Masashi Kakinoki
Riko Matsumoto
Yusuke Ichiyama
Tomoko Sawada
Yoshitsugu Saishin
Masahito Ohji
机构
[1] Shiga University of Medical Science,Department of Ophthalmology
来源
关键词
All quadrants; Axial length; Corneal astigmatism; Macular hole retinal detachment; Scleral imbrication;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:335 / 340
页数:5
相关论文
共 25 条
  • [1] Efficacy of scleral imbrication on all quadrants in enucleated pig eyes
    Sawada, Osamu
    Obata, Shumpei
    Kakinoki, Masashi
    Matsumoto, Riko
    Ichiyama, Yusuke
    Sawada, Tomoko
    Saishin, Yoshitsugu
    Ohji, Masahito
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2022, 66 (03) : 335 - 340
  • [2] CORNEAL AND SCLERAL DISTENSIBILITY RATIO ON ENUCLEATED HUMAN EYES
    RICHARDS, RD
    TITTEL, PG
    [J]. INVESTIGATIVE OPHTHALMOLOGY, 1973, 12 (02): : 145 - 151
  • [3] Retinal changes after retinal translocation surgery with scleral imbrication in dog eyes
    Hayashi, A
    Usui, S
    Kawaguchi, K
    Fujioka, S
    Kusaka, S
    Fujikado, T
    Ohji, M
    Tano, Y
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (13) : 4288 - 4292
  • [4] ARE THE RIGHT AND THE LEFT EYES OF AN INDIVIDUUM PARTICULARLY SIMILAR - PACHYMETRIC EXAMINATION OF ENUCLEATED PIG EYES
    SCHLOSSMACHER, BW
    KOTTEK, AA
    SCHRAGE, NF
    REIM, M
    [J]. VISION RESEARCH, 1995, 35 : P100 - P100
  • [5] Corneal astigmatism after scleral shortening in pig eyes
    Oshita, T
    Hayashi, S
    Hayashi, A
    Maeda, N
    Fujikado, T
    Tano, Y
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S452 - S452
  • [6] Topographic analysis of astigmatism induced by scleral shortening in pig eyes
    Oshita, T
    Hayashi, S
    Inoue, T
    Hayashi, A
    Maeda, N
    Kusaka, S
    Ohji, M
    Fujikado, T
    Tano, Y
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2001, 239 (05) : 382 - 386
  • [7] Topographic analysis of astigmatism induced by scleral shortening in pig eyes
    Takashi Oshita
    Shusuke Hayashi
    Tomoyuki Inoue
    Atsushi Hayashi
    Naoyuki Maeda
    Shunji Kusaka
    Masahito Ohji
    Takashi Fujikado
    Yasuo Tano
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2001, 239 : 382 - 386
  • [8] Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
    Leonardi, Matteo
    Pitchon, Elie M.
    Bertsch, Arnaud
    Renaud, Philippe
    Mermoud, Andre
    [J]. ACTA OPHTHALMOLOGICA, 2009, 87 (04) : 433 - 437
  • [9] Enzyme-assisted vitrectomy in enucleated pig eyes: a comparison of hyaluronidase, chondroitinase, and plasmin
    Staubach, F
    Nober, V
    Janknecht, P
    [J]. CURRENT EYE RESEARCH, 2004, 29 (4-5) : 261 - 268
  • [10] Accuracy and reliability of rebound tonometer to measure the IOP of enucleated pig eyes in vertical and horizontal positions
    Yoo, Youngcheol
    Lee, Ka Young
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)