Efficacy of scleral imbrication on all quadrants in enucleated pig eyes

被引:0
|
作者
Sawada, Osamu [1 ]
Obata, Shumpei [1 ]
Kakinoki, Masashi [1 ]
Matsumoto, Riko [1 ]
Ichiyama, Yusuke [1 ]
Sawada, Tomoko [1 ]
Saishin, Yoshitsugu [1 ]
Ohji, Masahito [1 ]
机构
[1] Shiga Univ Med Sci, Dept Ophthalmol, Seta Tukinowacho, Otsu, Shiga 5202192, Japan
关键词
All quadrants; Axial length; Corneal astigmatism; Macular hole retinal detachment; Scleral imbrication; MYOPIC TRACTION MACULOPATHY; RETINAL-DETACHMENT; GAS TAMPONADE; VITRECTOMY;
D O I
10.1007/s10384-022-00915-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate the changes in axial length (AL) and corneal astigmatism induced by scleral imbrication on all quadrants in pig eyes. Study design Experimental study Methods We produced scleral imbrications either on all quadrants or on 2 consecutive quadrants of 5 enucleated pig eyes. Scleral imbrications 8 mm wide were made at 8 mm from the limbus on each quadrant. We determined the AL using an electronic caliper and the corneal astigmatism using a keratometer before and after the 2 types of scleral imbrications and compared the changes in ocular AL and corneal astigmatism induced by the 2 surgical procedures. Results The AL reduction after the scleral imbrication on all quadrants (3.96 +/- 0.56 mm) was larger than that on 2 quadrants (2.39 +/- 0.41 mm) (P = .001). The change in corneal astigmatism induced by imbrication on all quadrants (2.98 +/- 1.96 D) was less than that on 2 quadrants (5.95 +/- 2.04 D) (P < .029). Conclusions Scleral imbrication on all quadrants induced a shorter AL and less corneal astigmatism than did a standard scleral imbrication on 2 quadrants. Therefore, the former could be a more effective operation for retinal disorders associated with high myopia, including macular hole retinal detachment and myopic foveoschisis.
引用
收藏
页码:335 / 340
页数:6
相关论文
共 25 条
  • [1] Efficacy of scleral imbrication on all quadrants in enucleated pig eyes
    Osamu Sawada
    Shumpei Obata
    Masashi Kakinoki
    Riko Matsumoto
    Yusuke Ichiyama
    Tomoko Sawada
    Yoshitsugu Saishin
    Masahito Ohji
    [J]. Japanese Journal of Ophthalmology, 2022, 66 : 335 - 340
  • [2] CORNEAL AND SCLERAL DISTENSIBILITY RATIO ON ENUCLEATED HUMAN EYES
    RICHARDS, RD
    TITTEL, PG
    [J]. INVESTIGATIVE OPHTHALMOLOGY, 1973, 12 (02): : 145 - 151
  • [3] Retinal changes after retinal translocation surgery with scleral imbrication in dog eyes
    Hayashi, A
    Usui, S
    Kawaguchi, K
    Fujioka, S
    Kusaka, S
    Fujikado, T
    Ohji, M
    Tano, Y
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (13) : 4288 - 4292
  • [4] ARE THE RIGHT AND THE LEFT EYES OF AN INDIVIDUUM PARTICULARLY SIMILAR - PACHYMETRIC EXAMINATION OF ENUCLEATED PIG EYES
    SCHLOSSMACHER, BW
    KOTTEK, AA
    SCHRAGE, NF
    REIM, M
    [J]. VISION RESEARCH, 1995, 35 : P100 - P100
  • [5] Corneal astigmatism after scleral shortening in pig eyes
    Oshita, T
    Hayashi, S
    Hayashi, A
    Maeda, N
    Fujikado, T
    Tano, Y
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S452 - S452
  • [6] Topographic analysis of astigmatism induced by scleral shortening in pig eyes
    Oshita, T
    Hayashi, S
    Inoue, T
    Hayashi, A
    Maeda, N
    Kusaka, S
    Ohji, M
    Fujikado, T
    Tano, Y
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2001, 239 (05) : 382 - 386
  • [7] Topographic analysis of astigmatism induced by scleral shortening in pig eyes
    Takashi Oshita
    Shusuke Hayashi
    Tomoyuki Inoue
    Atsushi Hayashi
    Naoyuki Maeda
    Shunji Kusaka
    Masahito Ohji
    Takashi Fujikado
    Yasuo Tano
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2001, 239 : 382 - 386
  • [8] Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
    Leonardi, Matteo
    Pitchon, Elie M.
    Bertsch, Arnaud
    Renaud, Philippe
    Mermoud, Andre
    [J]. ACTA OPHTHALMOLOGICA, 2009, 87 (04) : 433 - 437
  • [9] Enzyme-assisted vitrectomy in enucleated pig eyes: a comparison of hyaluronidase, chondroitinase, and plasmin
    Staubach, F
    Nober, V
    Janknecht, P
    [J]. CURRENT EYE RESEARCH, 2004, 29 (4-5) : 261 - 268
  • [10] Accuracy and reliability of rebound tonometer to measure the IOP of enucleated pig eyes in vertical and horizontal positions
    Yoo, Youngcheol
    Lee, Ka Young
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)