An initial investigation of a wireless patient radiation dosimeter for use in interventional radiology

被引:0
|
作者
Yohei Inaba
Koichi Chida
Yuuki Murabayashi
Mime Endo
Kazuki Otomo
Masayuki Zuguchi
机构
[1] Tohoku University Graduate School of Medicine,Department of Radiological Technology
[2] Tohoku University,Division of Disaster Medicine, International Research Institute of Disaster Science
来源
关键词
Interventional radiology (IR); Radiation safety; Dosimetry; Radiation protection; Radiation dose; Fluoroscopy;
D O I
暂无
中图分类号
学科分类号
摘要
Radiation exposure during interventional radiology (IR) procedures is a critical issue. We have developed a wireless real-time dosimeter for IR patients that use nontoxic phosphor (four sensors). We evaluated the basic performance parameters (such as dose linearity, batch uniformity, reproducibility, and wireless-communication conditions) of the developed system using an IR X-ray system. Further, we investigated the influence of noise from other medical equipment on our wireless real-time dosimeter in the IR X-ray room. Overall, our wireless system exhibited excellent performance in terms of uniformity, reproducibility, and linearity; moreover, the wireless communication performance was better. The developed system enabled real-time visualization of patient radiation dose, without noise contamination from other medical equipment. In addition, the wireless system can be easily installed in a location where the PC screen (display) can be readily viewed by the IR physician. Hence, we developed a wireless system that can display the patient radiation dose data in real time; the system performed satisfactorily upon application in radiation dosimetry. Therefore, our wireless system will facilitate the real-time monitoring/management of patient radiation dose during IR.
引用
收藏
页码:321 / 326
页数:5
相关论文
共 50 条
  • [1] An initial investigation of a wireless patient radiation dosimeter for use in interventional radiology
    Inaba, Yohei
    Chida, Koichi
    Murabayashi, Yuuki
    Endo, Mime
    Otomo, Kazuki
    Zuguchi, Masayuki
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (03) : 321 - 326
  • [2] Real-time patient radiation dosimeter for use in interventional radiology
    Chida, Koichi
    Kato, Mamoru
    Inaba, Yohei
    Kobayashi, Ryota
    Nakamura, Masaaki
    Abe, Yoshihisa
    Zuguchi, Masayuki
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (11): : 1475 - 1478
  • [3] Use of patient radiation shielding in diagnostic and interventional radiology
    Fiebich, M.
    Ammon, J.
    Borowski, M.
    Gala, H. de las Heras
    Loose, R.
    Mentzel, H. -j.
    Poppe, B.
    RADIOLOGIE, 2023, 63 (06): : 461 - 470
  • [4] Real-time wireless personal dosimeter for Interventional Radiology Procedures
    Servoli, L.
    Solestizi, L. Alunni
    Biasini, M.
    Bissi, L.
    Calandra, A.
    Chiatti, L.
    Cicioni, R.
    Di Lorenzo, R.
    Dipilato, A. C.
    Fabiani, S.
    Kanxheri, K.
    Italiani, M.
    Magalotti, D.
    Paolucci, M.
    Placidi, P.
    Scorzonia, A.
    Trivisonne, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 65 - 66
  • [5] Use of a CMOS Image Sensor for an Active Personal Dosimeter in Interventional Radiology
    Conti, Elia
    Placidi, Pisana
    Biasini, Maurizio
    Bissi, Lucia
    Calandra, Andrea
    Checcucci, Bruno
    Chiocchini, Stefania
    Cicioni, Roberto
    Di Lorenzo, Roberto
    Dipilato, Anna Concetta
    Esposito, Alessandro
    Paolucci, Massimiliano
    Passeri, Daniele
    Pentiricci, Andrea
    Scorzoni, Andrea
    Servoli, Leonello
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (05) : 1065 - 1072
  • [6] Novel Dosimeter Using a Nontoxic Phosphor for Real-Time Monitoring of Patient Radiation Dose in Interventional Radiology
    Nakamura, Masaaki
    Chida, Koichi
    Zuguchi, Masayuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (02) : W202 - W206
  • [7] Reference Levels for Patient Radiation Doses in Interventional Radiology: Proposed Initial Values for US Practice
    Miller, Donald L.
    Kwon, Deukwoo
    Bonavia, Grant H.
    RADIOLOGY, 2009, 253 (03) : 753 - 764
  • [8] A real time active pixel dosimeter for interventional radiology
    Paolucci, M.
    Battisti, D.
    Biasini, M.
    Checcucci, B.
    Di Lorenzo, R.
    Esposito, A.
    Fano, L.
    Passeri, D.
    Placidi, P.
    Servoli, L.
    RADIATION MEASUREMENTS, 2011, 46 (11) : 1271 - 1276
  • [9] Patient radiation doses and reference levels in pediatric interventional radiology
    Geryes, Bouchra Habib
    Bak, Adeline
    Lachaux, Julie
    Ozanne, Augustin
    Boddaert, Nathalie
    Brunelle, Francis
    Naggara, Olivier
    Saliou, Guillaume
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3983 - 3990
  • [10] Patient radiation doses and reference levels in pediatric interventional radiology
    Bouchra Habib Geryes
    Adeline Bak
    Julie Lachaux
    Augustin Ozanne
    Nathalie Boddaert
    Francis Brunelle
    Olivier Naggara
    Guillaume Saliou
    European Radiology, 2017, 27 : 3983 - 3990