Radiation exposure during interventional radiology (IR) procedures is a critical issue. We have developed a wireless real-time dosimeter for IR patients that use nontoxic phosphor (four sensors). We evaluated the basic performance parameters (such as dose linearity, batch uniformity, reproducibility, and wireless-communication conditions) of the developed system using an IR X-ray system. Further, we investigated the influence of noise from other medical equipment on our wireless real-time dosimeter in the IR X-ray room. Overall, our wireless system exhibited excellent performance in terms of uniformity, reproducibility, and linearity; moreover, the wireless communication performance was better. The developed system enabled real-time visualization of patient radiation dose, without noise contamination from other medical equipment. In addition, the wireless system can be easily installed in a location where the PC screen (display) can be readily viewed by the IR physician. Hence, we developed a wireless system that can display the patient radiation dose data in real time; the system performed satisfactorily upon application in radiation dosimetry. Therefore, our wireless system will facilitate the real-time monitoring/management of patient radiation dose during IR.
引用
收藏
页码:321 / 326
页数:5
相关论文
共 50 条
  • [31] Occupational Radiation Protection in Interventional Radiology: A Joint Guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology
    Miller, Donald L.
    Vano, Eliseo
    Bartal, Gabriel
    Balter, Stephen
    Dixon, Robert
    Padovani, Renato
    Schueler, Beth
    Cardella, John F.
    de Baere, Thierry
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (02) : 230 - 239
  • [32] Occupational Radiation Protection in Interventional Radiology: A Joint Guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology
    Miller, Donald L.
    Vano, Eliseo
    Bartal, Gabriel
    Balter, Stephen
    Dixon, Robert
    Padovani, Renato
    Schueler, Beth
    Cardella, John F.
    de Baere, Thierry
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (05) : 607 - 615
  • [33] Occupational Radiation Protection in Interventional Radiology: A Joint Guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology
    Donald L. Miller
    Eliseo Vañó
    Gabriel Bartal
    Stephen Balter
    Robert Dixon
    Renato Padovani
    Beth Schueler
    John F. Cardella
    Thierry de Baère
    CardioVascular and Interventional Radiology, 2010, 33 : 230 - 239
  • [34] Eye Lens Radiation Dose to Nurses during Cardiac Interventional Radiology: An Initial Study
    Yamada, Ayumi
    Haga, Yoshihiro
    Sota, Masahiro
    Abe, Mitsuya
    Kaga, Yuji
    Inaba, Yohei
    Suzuki, Masatoshi
    Tada, Norio
    Zuguchi, Masayuki
    Chida, Koichi
    DIAGNOSTICS, 2023, 13 (18)
  • [35] Radiation protection in interventional radiology.
    Adamus, R.
    Loose, R.
    Wucherer, M.
    Uder, M.
    Galster, M.
    RADIOLOGE, 2016, 56 (03): : 275 - 281
  • [36] Systematic Review of Use of Patient-Reported Outcomes in Interventional Radiology
    Datta, Sanjit
    Cramer, Peyton
    Sung, Jeffrey
    Wright, Drew
    Charalel, Resmi
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2023, 20 (08) : 752 - 757
  • [37] The use of ultrasonography in interventional radiology
    Mueller, PR
    SEMINARS IN INTERVENTIONAL RADIOLOGY, 1997, 14 (04) : 339 - 340
  • [38] Patient doses in interventional radiology: Accuracy in measurement and proper use of nomenclature
    McParland, BJ
    RADIOLOGY, 1998, 209 (02) : 589 - 590
  • [39] Radiation Protection Tools in Interventional Radiology
    Schueler, Beth A.
    Baiter, Stephen
    Miller, Donald L.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2012, 9 (11) : 844 - 845
  • [40] Radiation Protection and Safety in Interventional Radiology
    Wagner, Jessyca B.
    RADIOLOGIC TECHNOLOGY, 2020, 91 (05) : 431 - 444