Novel Dosimeter Using a Nontoxic Phosphor for Real-Time Monitoring of Patient Radiation Dose in Interventional Radiology

被引:22
|
作者
Nakamura, Masaaki [1 ]
Chida, Koichi [1 ,2 ]
Zuguchi, Masayuki [1 ]
机构
[1] Tokohu Univ, Coll Med Sci, Dept Radiol Technol, Aoba Ku, Sendai, Miyagi 9808575, Japan
[2] Tohoku Univ, Int Res Inst Disaster Technol, Div Disaster Med Sci, Sendai, Miyagi 980, Japan
基金
日本学术振兴会;
关键词
fluoroscopy; interventional radiology; patient skin dosimeter; radiation protection; real-time dose measurement; SKIN INJURIES; EXPOSURE;
D O I
10.2214/AJR.14.13925
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. To our knowledge, no feasible method exists for real-time measurement of the radiation dose given to the patient during interventional radiology (IR) procedures. Therefore, we produced a prototype of a real-time dosimeter for patients undergoing IR that uses a nontoxic phosphor. The basic characteristics of the real-time dosimeter prototype are comparable to those of the previously used skin dose monitor, with the exception that our prototype has the distinct advantage of including multichannel sensors. CONCLUSION. The novel real-time dosimeter system is expected to be useful for measuring patient exposure to the radiation dose during IR procedures.
引用
收藏
页码:W202 / W206
页数:5
相关论文
共 50 条
  • [1] Real-time patient radiation dosimeter for use in interventional radiology
    Chida, Koichi
    Kato, Mamoru
    Inaba, Yohei
    Kobayashi, Ryota
    Nakamura, Masaaki
    Abe, Yoshihisa
    Zuguchi, Masayuki
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (11): : 1475 - 1478
  • [2] Red emission phosphor for real-time skin dosimeter for fluoroscopy and interventional radiology
    Nakamura, Masaaki
    Chida, Koichi
    Zuguchi, Masayuki
    [J]. MEDICAL PHYSICS, 2014, 41 (10)
  • [3] Effectiveness of a novel real-time dosimeter in interventional radiology: a comparison of new and old radiation sensors
    Inaba Y.
    Nakamura M.
    Chida K.
    Zuguchi M.
    [J]. Radiological Physics and Technology, 2018, 11 (4) : 445 - 450
  • [4] Radiation Dose Reduction Using Real-Time Image Processing in Interventional Radiology
    Kanal, K.
    Moirano, J.
    Zamora, D.
    Stewart, B.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3347 - 3347
  • [5] Real-time wireless personal dosimeter for Interventional Radiology Procedures
    Servoli, L.
    Solestizi, L. Alunni
    Biasini, M.
    Bissi, L.
    Calandra, A.
    Chiatti, L.
    Cicioni, R.
    Di Lorenzo, R.
    Dipilato, A. C.
    Fabiani, S.
    Kanxheri, K.
    Italiani, M.
    Magalotti, D.
    Paolucci, M.
    Placidi, P.
    Scorzonia, A.
    Trivisonne, S.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 65 - 66
  • [6] Evaluation of a New Real-Time Dosimeter Sensor for Interventional Radiology Staff
    Hattori, Kenshin
    Inaba, Yohei
    Kato, Toshiki
    Fujisawa, Masaki
    Yasuno, Hikaru
    Yamada, Ayumi
    Haga, Yoshihiro
    Suzuki, Masatoshi
    Zuguchi, Masayuki
    Chida, Koichi
    [J]. SENSORS, 2023, 23 (01)
  • [7] Effect of Real-Time Radiation Dose Feedback on Pediatric Interventional Radiology Staff Radiation Exposure
    Racadio, John
    Nachabe, Rami
    Carelsen, Bart
    Racadio, Judy
    Hilvert, Nicole
    Johnson, Neil
    Kukreja, Kamlesh
    Patel, Manish
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 25 (01) : 119 - 126
  • [8] A real time active pixel dosimeter for interventional radiology
    Paolucci, M.
    Battisti, D.
    Biasini, M.
    Checcucci, B.
    Di Lorenzo, R.
    Esposito, A.
    Fano, L.
    Passeri, D.
    Placidi, P.
    Servoli, L.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (11) : 1271 - 1276
  • [9] A prototype real-time dose distribution monitoring system using plastic scintillators connected to optical fiber for interventional radiology
    Nishikido, Fumihiko
    Moritake, Takashi
    Ito, Hiroshi
    Yamaya, Taiga
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [10] Real-Time Patient and Staff Radiation Dose Monitoring in IR Practice
    Anna M. Sailer
    Leonie Paulis
    Laura Vergoossen
    Axel O. Kovac
    Geert Wijnhoven
    Geert Willem H. Schurink
    Barend Mees
    Marco Das
    Joachim E. Wildberger
    Michiel W. de Haan
    Cécile R. L. P. N. Jeukens