Novel Dosimeter Using a Nontoxic Phosphor for Real-Time Monitoring of Patient Radiation Dose in Interventional Radiology

被引:22
|
作者
Nakamura, Masaaki [1 ]
Chida, Koichi [1 ,2 ]
Zuguchi, Masayuki [1 ]
机构
[1] Tokohu Univ, Coll Med Sci, Dept Radiol Technol, Aoba Ku, Sendai, Miyagi 9808575, Japan
[2] Tohoku Univ, Int Res Inst Disaster Technol, Div Disaster Med Sci, Sendai, Miyagi 980, Japan
基金
日本学术振兴会;
关键词
fluoroscopy; interventional radiology; patient skin dosimeter; radiation protection; real-time dose measurement; SKIN INJURIES; EXPOSURE;
D O I
10.2214/AJR.14.13925
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. To our knowledge, no feasible method exists for real-time measurement of the radiation dose given to the patient during interventional radiology (IR) procedures. Therefore, we produced a prototype of a real-time dosimeter for patients undergoing IR that uses a nontoxic phosphor. The basic characteristics of the real-time dosimeter prototype are comparable to those of the previously used skin dose monitor, with the exception that our prototype has the distinct advantage of including multichannel sensors. CONCLUSION. The novel real-time dosimeter system is expected to be useful for measuring patient exposure to the radiation dose during IR procedures.
引用
下载
收藏
页码:W202 / W206
页数:5
相关论文
共 50 条
  • [41] Room staff radiation dose in a vascular surgery hybrid operating room and evaluation of a real-time radiation dosimeter
    Jungi, S.
    Schweizer, V.
    Ante, M.
    Geisbuesch, P.
    Boeckler, D.
    BRITISH JOURNAL OF SURGERY, 2021, 108
  • [42] An Innovative Real-Time Dosimeter for Radiation Hardness Assurance Tests
    Campajola, Luigi
    Casolaro, Pierluigi
    Gandolfo, Elisa Maria
    Campajola, Marcello
    Buontempo, Salvatore
    Di Capua, Francesco
    PHYSICS, 2022, 4 (02) : 409 - 420
  • [43] Real-Time Plastic Scintillation Dosimeter for Fluoroscopically-Guided Interventional Procedures
    Boivin, J.
    Guillemette, M.
    Beaulieu, L.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [44] Monitoring and Follow-Up of High Radiation Dose Cases in Interventional Radiology
    Perry, Brandon C.
    Ingraham, Christopher R.
    Stewart, Brent K.
    Valji, Karim
    Kanal, Kalpana M.
    ACADEMIC RADIOLOGY, 2019, 26 (02) : 163 - 169
  • [45] Real-Time Patient and Staff Dose Monitoring in Fluoroscopy Guided Interventions
    Vergoossen, L.
    Sailer, A.
    Paulis, L.
    Wildberger, J.
    Jeukens, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3669 - 3669
  • [46] Changes in Occupational Radiation Exposures after Incorporation of a Real-time Dosimetry System in the Interventional Radiology Suite
    Poudel, Sashi
    Weir, Lori
    Dowling, Dawn
    Medich, David C.
    HEALTH PHYSICS, 2016, 111 (02): : S166 - S171
  • [47] REAL-TIME, IN-VIVO MEASUREMENT OF RADIATION-DOSE DURING RADIOIMMUNOTHERAPY IN MICE USING A MINIATURE MOSFET DOSIMETER PROBE
    GLADSTONE, DJ
    CHIN, LM
    RADIATION RESEARCH, 1995, 141 (03) : 330 - 335
  • [48] Patient Radiation Doses in Interventional Radiology Procedures: Comparison of Fluoroscopy Dose Indices between the American College of Radiology Dose Index Registry-Fluoroscopy Pilot and the Radiation Doses in Interventional Radiology Study
    Jones, A. Kyle
    Wunderle, Kevin A.
    Fruscello, Tom
    Simanowith, Michael
    Cline, Brendan
    Dharmadhikari, Shalmali
    Duan, Xinhui
    Durack, Jeremy C.
    Hirschl, David
    Kim, Don-Soo
    Mahmood, Usman
    Mann, Steve D.
    Martin, Charles
    Metwalli, Zeyad
    Moirano, Jeffrey M.
    Neill, Rebecca A.
    Newsome, Janice
    Padua, Horacio
    Schoenfeld, Alan H.
    Miller, Donald L.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 34 (04)
  • [50] A new real-time personal dosimeter with position monitoring based on a scintillator
    Moon, Sun Young
    Yoon, Myonggeun
    Kim, Sun-Young
    Shin, Dongho
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2021, 78 (11) : 1133 - 1140