A new real-time personal dosimeter with position monitoring based on a scintillator

被引:0
|
作者
Moon, Sun Young [1 ]
Yoon, Myonggeun [1 ]
Kim, Sun-Young [2 ]
Shin, Dongho [2 ]
机构
[1] Korea Univ, Dept Bioconvergence Engn, Seoul, South Korea
[2] Natl Canc Ctr, Proton Therapy Ctr, Goyang, South Korea
基金
新加坡国家研究基金会;
关键词
Personal dosimeter; Scintillator; Occupational dosimetry; Real-time dosimeter;
D O I
10.1007/s40042-021-00075-5
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Personal dosimeters are used to measure the amount of radiation exposure in individual radiation workers. We aimed to replace existing personal dosimeters and evaluate a real-time scintillator-based dosimeter by monitoring its radiation dose and checking the location exposed to radiation in the workspace. The developed dosimeter measured the radiation dose based on a scintillating fiber (SF) bundle, and comprised a silicon photomultiplier (SiPM), ultra-wide-band (UWB)-based location detecting system, and Bluetooth system. The SF bundle was exposed to radiation-emitted light, and the photons were amplified and converted to electrical signals through the SiPM. These signals were transferred to the user through the Bluetooth system and monitored. To evaluate the feasibility of this mechanism as a dosimeter, we performed characteristic tests, such as dose linearity, dependence on dose rate, energy, exposed angle, and location coordinate mapping. Also, the dose distribution formed in circles around the iso-center was measured to confirm the feasibility of monitoring the exposure dose and location and to enable the radiation worker to move freely in a workspace. We confirmed dose linearity, independence from energy and angle, and accuracy of location monitoring in our device. The user's locations were measured with a difference of - 6 cm and - 4.8 cm on the x- and the y-axes, respectively. The measured doses on our developed dosimeter were 62.7, 32.3, 21.0, and 15.4 mSv at distances of 50, 100, 150, and 200 cm from the iso-center. In other words, all measured doses at several points showed an error within 5% as compared to doses provided by the conventional pocket dosimeter. These results show that the developed SF-based dosimeter is advantageous in monitoring the exposure dose and location in real time, and has significant potential as a new personal dosimeter for radiation workers.
引用
下载
收藏
页码:1133 / 1140
页数:8
相关论文
共 50 条
  • [1] A new real-time personal dosimeter with position monitoring based on a scintillator
    Sun Young Moon
    Myonggeun Yoon
    Sun-Young Kim
    Dongho Shin
    Journal of the Korean Physical Society, 2021, 78 : 1133 - 1140
  • [2] Real-time wireless personal dosimeter for Interventional Radiology Procedures
    Servoli, L.
    Solestizi, L. Alunni
    Biasini, M.
    Bissi, L.
    Calandra, A.
    Chiatti, L.
    Cicioni, R.
    Di Lorenzo, R.
    Dipilato, A. C.
    Fabiani, S.
    Kanxheri, K.
    Italiani, M.
    Magalotti, D.
    Paolucci, M.
    Placidi, P.
    Scorzonia, A.
    Trivisonne, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 65 - 66
  • [3] Design of a new real-time dosimeter to monitor personal exposure to elemental gaseous mercury
    Mattoli, V.
    Mazzolai, B.
    Raffa, V.
    Mondini, A.
    Dario, P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (01): : 158 - 167
  • [4] DEVELOPMENT OF REAL-TIME PERSONAL NEUTRON DOSIMETER WITH 2 SILICON DETECTORS
    NAKAMURA, T
    TSUJIMURA, N
    YAMANO, T
    APPLIED RADIATION AND ISOTOPES, 1995, 46 (6-7) : 469 - 470
  • [6] A swallowable X-ray dosimeter for the real-time monitoring of radiotherapy
    Bo Hou
    Luying Yi
    Dehong Hu
    Zichao Luo
    Duyang Gao
    Chao Li
    Bowen Xing
    Jiong-Wei Wang
    Chuen Neng Lee
    Rong Zhang
    Zonghai Sheng
    Bin Zhou
    Xiaogang Liu
    Nature Biomedical Engineering, 2023, 7 : 1242 - 1251
  • [7] A swallowable X-ray dosimeter for the real-time monitoring of radiotherapy
    Hou, Bo
    Yi, Luying
    Hu, Dehong
    Luo, Zichao
    Gao, Duyang
    Li, Chao
    Xing, Bowen
    Wang, Jiong-Wei
    Lee, Chuen Neng
    Zhang, Rong
    Sheng, Zonghai
    Zhou, Bin
    Liu, Xiaogang
    NATURE BIOMEDICAL ENGINEERING, 2023, 7 (10) : 1242 - +
  • [8] Real-time monitoring of personal exposures to carbon dioxide
    Gall, Elliott T.
    Cheung, Toby
    Luhung, Irvan
    Schiavon, Stefano
    Nazaroff, William W.
    BUILDING AND ENVIRONMENT, 2016, 104 : 59 - 67
  • [9] Real-time personal protective equipment monitoring system
    Barro-Torres, Santiago
    Fernandez-Carames, Tiago M.
    Perez-Iglesias, Hector J.
    Escudero, Carlos J.
    COMPUTER COMMUNICATIONS, 2012, 36 (01) : 42 - 50
  • [10] A real-time pulsed photon dosimeter
    Brown, D
    Olsher, RH
    Eisen, Y
    Rodriguez, JF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 373 (01): : 139 - 147