A new real-time personal dosimeter with position monitoring based on a scintillator

被引:0
|
作者
Moon, Sun Young [1 ]
Yoon, Myonggeun [1 ]
Kim, Sun-Young [2 ]
Shin, Dongho [2 ]
机构
[1] Korea Univ, Dept Bioconvergence Engn, Seoul, South Korea
[2] Natl Canc Ctr, Proton Therapy Ctr, Goyang, South Korea
基金
新加坡国家研究基金会;
关键词
Personal dosimeter; Scintillator; Occupational dosimetry; Real-time dosimeter;
D O I
10.1007/s40042-021-00075-5
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Personal dosimeters are used to measure the amount of radiation exposure in individual radiation workers. We aimed to replace existing personal dosimeters and evaluate a real-time scintillator-based dosimeter by monitoring its radiation dose and checking the location exposed to radiation in the workspace. The developed dosimeter measured the radiation dose based on a scintillating fiber (SF) bundle, and comprised a silicon photomultiplier (SiPM), ultra-wide-band (UWB)-based location detecting system, and Bluetooth system. The SF bundle was exposed to radiation-emitted light, and the photons were amplified and converted to electrical signals through the SiPM. These signals were transferred to the user through the Bluetooth system and monitored. To evaluate the feasibility of this mechanism as a dosimeter, we performed characteristic tests, such as dose linearity, dependence on dose rate, energy, exposed angle, and location coordinate mapping. Also, the dose distribution formed in circles around the iso-center was measured to confirm the feasibility of monitoring the exposure dose and location and to enable the radiation worker to move freely in a workspace. We confirmed dose linearity, independence from energy and angle, and accuracy of location monitoring in our device. The user's locations were measured with a difference of - 6 cm and - 4.8 cm on the x- and the y-axes, respectively. The measured doses on our developed dosimeter were 62.7, 32.3, 21.0, and 15.4 mSv at distances of 50, 100, 150, and 200 cm from the iso-center. In other words, all measured doses at several points showed an error within 5% as compared to doses provided by the conventional pocket dosimeter. These results show that the developed SF-based dosimeter is advantageous in monitoring the exposure dose and location in real time, and has significant potential as a new personal dosimeter for radiation workers.
引用
下载
收藏
页码:1133 / 1140
页数:8
相关论文
共 50 条
  • [21] Real-time dosimeter targeted to nuclear applications
    Correia, Alexandre
    Rosa, Carla C.
    Santos, Pedro M. P.
    Falcao, Antonio N.
    Lorentz, Katharina
    SECOND INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS, 2014, 9286
  • [22] Real-time coil position monitoring system for biomagnetic measurements
    Oyama, Daisuke
    Adachi, Yoshiaki
    Higuchi, Masanori
    Kawai, Jun
    Kobayashi, Koichiro
    Uehara, Gen
    SUPERCONDUCTIVITY CENTENNIAL CONFERENCE 2011, 2012, 36 : 280 - 285
  • [23] Real-Time Optical Fiber Dosimeter Probe
    Croteau, Andre
    Caron, Serge
    Rink, Alexandra
    Jaffray, David
    Mermut, Ozzy
    OPTICAL FIBERS, SENSORS, AND DEVICES FOR BIOMEDICAL DIAGNOSTICS AND TREATMENT XI, 2011, 7894
  • [24] A REAL-TIME WIDE ENERGY-RANGE PERSONAL NEUTRON DOSIMETER WITH 2 SILICON DETECTORS
    NAKAMURA, T
    HORIGUCHI, M
    SUZUKI, T
    YAMANO, T
    RADIATION PROTECTION DOSIMETRY, 1989, 27 (03) : 149 - 156
  • [25] FPGA-Based Real-Time n/γ Discrimination With Liquid Scintillator
    Zhu, Xing
    Feng, Changqing
    Li, Qiang
    Shen, Zhongtao
    Liu, Shubin
    An, Qi
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (12) : 2877 - 2882
  • [26] ORGANIC SCINTILLATOR FOR REAL-TIME NEUTRON DOSIMETRY
    Beyer, Kyle A.
    Di Fulvio, Angela
    Stolarczyk, Liliana
    Parol, Wiktor
    Mojzeszek, Natalia
    Kopec, Renata
    Clarke, Shaun D.
    Pozzi, Sara A.
    RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 355 - 359
  • [27] New real-time patient radiation dosimeter for use in radiofrequency catheter ablation
    Kato, Mamoru
    Chida, Koichi
    Nakamura, Masaaki
    Toyoshima, Hideto
    Terata, Ken
    Abe, Yoshihisa
    JOURNAL OF RADIATION RESEARCH, 2019, 60 (02) : 215 - 220
  • [28] Real-time Personal Identification based on Haptic Information
    Tsuji, Toshiaki
    Arakawa, Junichi
    2011 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2011, : 1354 - 1359
  • [29] A novel approach for real time neutron radiation monitoring based on the bubble dosimeter
    Debowski, W.
    Przygoda, K.
    Jablonski, G.
    Napieralski, A.
    Mukherjee, B.
    MIXDES 2008: PROCEEDINGS OF THE 15TH INTERNATIONAL CONFERENCE ON MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2008, : 93 - +
  • [30] Real-Time Monitoring of Personal Protective Equipment Compliance in Surveillance Cameras
    Al-Azani, Sadam
    Luqman, Hamzah
    Alfarraj, Motaz
    Sidig, Ala Addin I.
    Khan, Ayaz H.
    Al-Hamed, Dina
    IEEE ACCESS, 2024, 12 : 121882 - 121895