Unicortical PEEK inset locking fixation for metacarpal fractures: a biomechanical study

被引:1
|
作者
Mudrick C.A. [1 ]
Owen J.R. [2 ]
Wayne J.S. [2 ]
Isaacs J.E. [1 ]
机构
[1] Orthopaedic Research Laboratory, Departments of Orthopaedic Surgery and Biomedical Engineering, Virginia Commonwealth University, P.O. Box 980153, Richmond, 23298-0153, VA
[2] Orthopaedic Research Laboratory, Departments of Orthopaedic Surgery and Biomedical Engineering, Virginia Commonwealth University, P.O. Box 980694, Richmond, 23298-0153, VA
关键词
Bending load; Failure; Internal fixation; polyetheretherketone (PEEK); Porcine metacarpal;
D O I
10.1007/s00590-013-1322-y
中图分类号
学科分类号
摘要
Purpose: There are numerous constructs employed in the treatment of metacarpal fractures with varying degrees of success. While plate fixation commonly involves dorsal application of a bicortical non-locking plate, there has been recent exploration of other fixation options including unicortical locked plating. The purpose of this study was to evaluate the biomechanical integrity of a polyetheretherketone (PEEK) inset locking plate and, in doing so, compare it to standard plate fixation (utilizing a clinically proven bicortical non-locking titanium plate) in a simulated porcine metacarpal fracture model.; Methods: Reproducible mid-shaft fractures were created in porcine second metacarpals. The fractured specimens were reduced and plated with either a bicortical non-locking plate or a unicortical locking plate with a PEEK locking design. Constructs were then loaded to failure in the same fashion as performed to create the fracture. Peak load was measured as the apex on the load-to-failure deflection curve. Stiffness was calculated as the linear slope on the load-to-failure deflection curve. Data were analyzed via Student’s t test.; Results: Unicortical locking constructs failed at 344 ± 119 N, while bicortical non-locking constructs were found to fail at 277 ± 101 N (p = 0.19). The unicortical locking constructs demonstrated a stiffness of 80 ± 36 N/mm compared with the bicortical non-locking constructs (69 ± 36 N/mm) although again the difference was not found to be statistically different (p = 0.49).; Conclusion: Based on this study, a locked plating construct using a polymer mechanism provides an interesting new locking fixation method for small bone fractures and with our limited number of specimens tested, provided at least a similar strength and rigidity profile in comparison with bicortical fixation in the treatment of metacarpal fractures. © 2013, Springer-Verlag France.
引用
收藏
页码:1415 / 1420
页数:5
相关论文
共 50 条
  • [11] Plating of metacarpal fractures: Unicortical or bicortical screws?
    Dona, E
    Gillies, RM
    Gianoutsos, MP
    Walsh, WR
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2004, 29B (03): : 218 - 221
  • [12] Evaluation of Unicortical Locking Screw Placement for Torsional Loads in Distal Radius Fractures: A Biomechanical Study in Cadavers
    Pehlivan, Ali T.
    Kilinc, Bekir E.
    Oc, Yunus
    Vezirhuyuk, Mustafa
    Yamak, Fatih
    Bozdag, Ergun
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (08)
  • [13] Fixation of HA-Coated unicortical locking screws in a sheep gap model: A comparative biomechanical study
    Moroni, Antonio
    Pegreffi, Francesco
    Hoang-Kim, Amy
    Tesei, Federico
    Giannini, Sandro
    Wippermann, Burkhardt
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (01) : 37 - 42
  • [14] Intramedullary screw fixation for metacarpal shaft fractures: a biomechanical human cadaver study
    Laber, Raffael
    Jann, David
    Behm, Pascal
    Ferguson, Stephen J.
    Frueh, Florian S.
    Calcagni, Maurizio
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (06) : 595 - 600
  • [15] Biomechanical Comparison of Bicortical Locking Versus Unicortical Far-Cortex-Abutting Locking Screw-Plate Fixation for Comminuted Radial Shaft Fractures
    Overturf, Steven J.
    Morris, Randal P.
    Gugala, Zbigniew
    Lindsey, Ronald W.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (10): : 1907 - 1913
  • [16] Comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fracture
    Shanmugam, Rukmanikanthan
    Jian, Chong Yin Chyi Chong Shyh
    Haseeb, Amber
    Aik, Saw
    JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (03):
  • [17] Commentary on "Biomechanical Comparison of Bicortical Locking Versus Unicortical Far-Cortex-Abutting Locking Screw-Plate Fixation for Comminuted Radial Shaft Fractures"
    Pappas, Nick D.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (10): : 1914 - 1914
  • [18] A biomechanical study comparing plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to cyclic loading
    Afshar, R.
    Fong, T. S.
    Latifi, M. Hadi
    Kanthan, S. R.
    Kamarul, T.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2012, 37E (05) : 396 - 401
  • [19] COMPARATIVE BIOMECHANICAL STABILITY OF TITANIUM BONE FIXATION SYSTEMS IN METACARPAL FRACTURES
    PREVEL, CD
    MCCARTY, M
    KATONA, T
    MOORE, K
    JACKSON, JR
    EPPLEY, BL
    SOOD, R
    ANNALS OF PLASTIC SURGERY, 1995, 35 (01) : 6 - 14
  • [20] Biomechanical Analysis of the Efficacy of Locking Plates during Cyclic Loading in Metacarpal Fractures
    Doht, Stefanie
    Meffert, Rainer H.
    Raschke, Michael J.
    Blunk, Torsten
    Ochman, Sabine
    SCIENTIFIC WORLD JOURNAL, 2014,