Comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fracture

被引:2
|
作者
Shanmugam, Rukmanikanthan [1 ]
Jian, Chong Yin Chyi Chong Shyh [1 ]
Haseeb, Amber [1 ]
Aik, Saw [1 ]
机构
[1] Univ Malaya, Fac Med, Dept Orthopaed Surg NOCERAL, Kuala Lumpur 50603, Malaysia
来源
JOURNAL OF ORTHOPAEDIC SURGERY | 2018年 / 26卷 / 03期
关键词
compression plate; locking plate; metacarpal fracture; unicortical locking plate; FIXATION; COMPLICATIONS; PHALANGEAL; HAND; SCREWS;
D O I
10.1177/2309499018802511
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Metacarpal bone fractures constitute 10% of all fractures. Unstable metacarpal fractures require surgical intervention, which poses danger to flexor tendon either due to bicortical drilling or construct of the implant. Unicortical locking plate fixation may be the solution to preventing flexor tendon injury. Studies have compared locking and compression plates. However, in these studies, the biomechanical properties were tested using the static loading method. This study looks into cyclical loading that is more representative of in vivo conditions, particularly for early rehabilitation. We compared the biomechanical strength of the unicortical locking plate and bicortical compression plate system in a transverse metacarpal fracture, tested with cyclical loading and torsion. Method: Twenty pieces of fourth-generation, biomechanical testing grade, left third metacarpal composite bones were used. Resin was used to create the holding block at both ends of the bone. An oscillating saw with 0.8 mm thick saw blade was used to osteotomize the metacarpal sawbones to create a midshaft transverse metacarpal fracture model. Ten pieces were fixed with a 2.0 mm titanium locking plate via unicortical screw purchase and 10 were fixed with a 2.0 mm, four holes, titanium dynamic compression plate, bicortical purchase of screws. They were subjected to cyclic load to failure testing three-point bending and torsion. Results: There were no significant difference in stiffness and cyclic three-point bending to failure between the unicortical locking plate group and the bicortical compression plate group. The bicortical compression plate group is stiffer and has a higher cyclic bending load to failure as compared to the unicortical locking plate group. Conclusion: Unicortical locking plate fixation of metacarpal fracture can be reliably applied clinically to produce a strong and stable construct that allows early mobilization of the joints. This will not only reduce the complication rate of metacarpal plating, but also improve the functional outcome of the hand.
引用
下载
收藏
页数:10
相关论文
共 50 条
  • [1] A biomechanical study comparing plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to cyclic loading
    Afshar, R.
    Fong, T. S.
    Latifi, M. Hadi
    Kanthan, S. R.
    Kamarul, T.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2012, 37E (05) : 396 - 401
  • [2] Unicortical versus bicortical plate fixation for midshaft clavicular fractures
    Ernesto Zaidenberg, Ezequiel
    Andres Rossi, Luciano
    Francisco, Federico
    Tanoira, Ignacio
    Pasqualini, Ignacio
    Ranalletta, Maximiliano
    Rodolfo Zaidenberg, Carlos
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54
  • [3] Unicortical Versus Bicortical Locked Plate Fixation in Midshaft Clavicle Fractures
    Bravman, Jonathan T.
    Taylor, Michal L.
    Baldini, Todd
    Vidal, Armando F.
    ORTHOPEDICS, 2015, 38 (05) : E411 - E416
  • [4] Biomechanical evaluation of locking plate radial shaft fixation: Unicortical locking fixation versus mixed bicortical and unicortical fixation in a sawbone model
    Roberts, Jason W.
    Grindel, Steven I.
    Rebholz, Brandon
    Wang, Mei
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (07): : 971 - 975
  • [5] A biomechanical analysis of plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to 4-point bending and dynamical bending test
    Liodaki, Eirini
    Wendlandt, Robert
    Waizner, Klaus
    Schopp, Brigitte E.
    Mailaender, Peter
    Stang, Felix
    MEDICINE, 2017, 96 (27)
  • [6] Comparison of the fixation ability of headless compression screws and locking plate for metacarpal shaft transverse fracture
    Chiu, Yung-Cheng
    Hsu, Cheng-En
    Ho, Tsung-Yu
    Ting, Yen-Nien
    Wei, Bor-Han
    Tsai, Ming-Tzu
    Hsu, Jui-Ting
    MEDICINE, 2021, 100 (39) : E27375
  • [7] Biomechanical Comparison of Bicortical Locking Versus Unicortical Far-Cortex-Abutting Locking Screw-Plate Fixation for Comminuted Radial Shaft Fractures
    Overturf, Steven J.
    Morris, Randal P.
    Gugala, Zbigniew
    Lindsey, Ronald W.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (10): : 1907 - 1913
  • [8] Commentary on "Biomechanical Comparison of Bicortical Locking Versus Unicortical Far-Cortex-Abutting Locking Screw-Plate Fixation for Comminuted Radial Shaft Fractures"
    Pappas, Nick D.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (10): : 1914 - 1914
  • [9] Locking, multidimensional plate osteosynthesis of midshaft clavicle fracture
    Dezulovic, M.
    Stangl, R.
    Muenzberg, M.
    UNFALLCHIRURG, 2013, 116 (02): : 138 - +
  • [10] A biomechanical study of headless compression screws versus a locking plate in radial head fracture fixation
    Rebgetz, Paul R.
    Daniele, Luca
    Underhill, Ian D.
    Ochsner, Andreas
    Taylor, Fraser J.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (04) : E111 - E116