Laser diode thermal desorption atmospheric pressure chemical ionization tandem mass spectrometry applied for the ultra-fast quantitative analysis of BKM120 in human plasma

被引:0
|
作者
Christian Lanshoeft
Olivier Heudi
Luc Alexis Leuthold
Götz Schlotterbeck
Walid Elbast
Franck Picard
Olivier Kretz
机构
[1] Novartis Pharma AG,School of Life Sciences, Institute for Chemistry and Bioanalytics
[2] DMPK/Bioanalytics,undefined
[3] University of Applied Sciences Northwestern Switzerland,undefined
来源
关键词
Laser diode thermal desorption; Liquid chromatography tandem mass spectrometry; Salting-out assisted liquid-liquid extraction; Bioanalysis; Validation; Pharmacokinetic;
D O I
暂无
中图分类号
学科分类号
摘要
A sensitive and ultra-fast method utilizing the laser diode thermal desorption ion source using atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS) was developed for the quantitative analysis of BKM120, an investigational anticancer drug in human plasma. Samples originating from protein precipitation (PP) followed by salting-out assisted liquid-liquid extraction (SALLE) were spotted onto the LazWell™ plate prior to their thermal desorption and detection by tandem mass spectrometry in positive mode. The validated method described in this paper presents a high absolute extraction recovery (>90 %) for BKM120 and its internal standard (ISTD) [D8]BKM120, with precision and accuracy meeting the acceptance criteria. Standard curves were linear over the range of 5.00 to 2000 ng mL−1 with a coefficient of determination (R2) >0.995. The method specificity was demonstrated in six different batches of human plasma. Intra- and inter-run precision as well as accuracy within ±20 % at the lower limit of quantification (LLOQ) and ±15 % (other levels) were achieved during a three-run validation for quality control (QC) samples. The post-preparative stability on the LazWell™ plate at room temperature was 72 h and a 200-fold dilution of spiked samples was demonstrated. The method was applied successfully to three clinical studies (n = 847) and cross-checked with the validated LC-ESI-MS/MS reference method. The sample analysis run time was 10 s as compared to 4.5 min for the current validated LC-ESI-MS/MS method. The resultant data were in agreement with the results obtained using the validated reference LC-ESI-MS/MS assay and the same pharmacokinetic (PK) parameters were calculated for both analytical assays. This work demonstrates that LDTD-APCI-MS/MS is a reliable method for the ultra-fast quantitative analysis of BKM120 which can be used to speed-up and support its bioanalysis in the frame of the clinical trials.
引用
收藏
页码:5413 / 5423
页数:10
相关论文
共 50 条
  • [31] Fast Screening of Authentic Ginseng Products by Surface Desorption Atmospheric Pressure Chemical Ionization Mass Spectrometry
    Yue, Hao
    Ma, Li
    Pi, Zifeng
    Chen, Huanwen
    Wang, Yang
    Hu, Bin
    Liu, Shuying
    PLANTA MEDICA, 2013, 79 (02) : 169 - 174
  • [32] Diclofenac in municipal wastewater treatment plant: quantification using laser diode thermal desorption-atmospheric pressure chemical ionization-tandem mass spectrometry approach in comparison with an established liquid chromatography-electrospray ionization-tandem mass spectrometry method
    Lonappan, Linson
    Pulicharla, Rama
    Rouissi, Tarek
    Brar, Satinder K.
    Verma, Mausam
    Surampalli, Rao Y.
    Valero, Jose R.
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1433 : 106 - 113
  • [33] Electrospray ionization and atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry of antioxidants applied in lubricants
    Kassler, Alexander
    Pittenauer, Ernst
    Doerr, Nicole
    Allmaier, Guenter
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (24) : 3917 - 3927
  • [34] High-Throughput Quantitation of Seven Sulfonamide Residues in Dairy Milk using Laser Diode Thermal Desorption-Negative Mode Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry
    Segura, Pedro A.
    Tremblay, Patrice
    Picard, Pierre
    Gagnon, Christian
    Sauve, Sebastien
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2010, 58 (03) : 1442 - 1446
  • [35] Quantitative analysis of pesticide residues in tea by gas chromatography-tandem mass spectrometry with atmospheric pressure chemical ionization
    Saito-Shida, Shizuka
    Nagata, Mari
    Nemoto, Satoru
    Akiyama, Hiroshi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1143
  • [36] Quantitative determination of amlodipine in serum by liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry
    Yasuda, T
    Tanaka, M
    Iba, K
    JOURNAL OF MASS SPECTROMETRY, 1996, 31 (08): : 879 - 884
  • [37] Differential Analysis of Camphor Wood Products by Desorption Atmospheric Pressure Chemical Ionization Mass Spectrometry
    Zhu, Liang
    Yan, Jianping
    Zhu, Zhiqiang
    Ouyang, Yongzhong
    Zhang, Xinglei
    Zhang, Wenjun
    Dai, Ximo
    Luo, Liping
    Chen, Huanwen
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2013, 61 (03) : 547 - 552
  • [38] The analysis of salen complexes by fast atom bombardment mass spectrometry and atmospheric pressure chemical ionization mass spectrometry
    Huang, SK
    Rood, MH
    Zhao, SH
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (09) : 996 - 1009
  • [39] Using a novel sol-gel stir bar sorptive extraction method for the analysis of steroid hormones in water by laser diode thermal desorption/atmospheric chemical ionization tandem mass spectrometry
    Duy, S. Vo
    Fayad, P. B.
    Barbeau, B.
    Prevost, M.
    Sauve, S.
    TALANTA, 2012, 101 : 337 - 345
  • [40] Determination of tamsulosin in dog plasma by liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry
    Qi, ML
    Wang, P
    Liu, LH
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (01): : 7 - 11