Laser diode thermal desorption atmospheric pressure chemical ionization tandem mass spectrometry applied for the ultra-fast quantitative analysis of BKM120 in human plasma

被引:0
|
作者
Christian Lanshoeft
Olivier Heudi
Luc Alexis Leuthold
Götz Schlotterbeck
Walid Elbast
Franck Picard
Olivier Kretz
机构
[1] Novartis Pharma AG,School of Life Sciences, Institute for Chemistry and Bioanalytics
[2] DMPK/Bioanalytics,undefined
[3] University of Applied Sciences Northwestern Switzerland,undefined
来源
关键词
Laser diode thermal desorption; Liquid chromatography tandem mass spectrometry; Salting-out assisted liquid-liquid extraction; Bioanalysis; Validation; Pharmacokinetic;
D O I
暂无
中图分类号
学科分类号
摘要
A sensitive and ultra-fast method utilizing the laser diode thermal desorption ion source using atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS) was developed for the quantitative analysis of BKM120, an investigational anticancer drug in human plasma. Samples originating from protein precipitation (PP) followed by salting-out assisted liquid-liquid extraction (SALLE) were spotted onto the LazWell™ plate prior to their thermal desorption and detection by tandem mass spectrometry in positive mode. The validated method described in this paper presents a high absolute extraction recovery (>90 %) for BKM120 and its internal standard (ISTD) [D8]BKM120, with precision and accuracy meeting the acceptance criteria. Standard curves were linear over the range of 5.00 to 2000 ng mL−1 with a coefficient of determination (R2) >0.995. The method specificity was demonstrated in six different batches of human plasma. Intra- and inter-run precision as well as accuracy within ±20 % at the lower limit of quantification (LLOQ) and ±15 % (other levels) were achieved during a three-run validation for quality control (QC) samples. The post-preparative stability on the LazWell™ plate at room temperature was 72 h and a 200-fold dilution of spiked samples was demonstrated. The method was applied successfully to three clinical studies (n = 847) and cross-checked with the validated LC-ESI-MS/MS reference method. The sample analysis run time was 10 s as compared to 4.5 min for the current validated LC-ESI-MS/MS method. The resultant data were in agreement with the results obtained using the validated reference LC-ESI-MS/MS assay and the same pharmacokinetic (PK) parameters were calculated for both analytical assays. This work demonstrates that LDTD-APCI-MS/MS is a reliable method for the ultra-fast quantitative analysis of BKM120 which can be used to speed-up and support its bioanalysis in the frame of the clinical trials.
引用
收藏
页码:5413 / 5423
页数:10
相关论文
共 50 条
  • [21] Quantitative determination of rivastigmine and its major metabolite in human plasma by liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry
    Pommier, F
    Frigola, R
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 784 (02): : 301 - 313
  • [22] Imaging Melamine in Egg Samples by Surface Desorption Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry
    Yang Shui-Ping
    Chen Huan-Wen
    Yang Yu-Ling
    Hu Bin
    Zhang Xie
    Zhou Yu-Fen
    Zang Li-Li
    Gu Hai-Wei
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (03) : 315 - 318
  • [23] Rapid Detection of Powdered Antibiotics by Surface Desorption Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry
    Chen, Rong
    Lilin, Shi
    Yang, Shui-Ping
    Shen-Tu, Jing-Ling
    Liang, Wen-Fang
    Chen, Huan-Wen
    Zhang, Li-Li
    Huan, Yan-Fu
    RESEARCH JOURNAL OF CHEMISTRY AND ENVIRONMENT, 2010, 14 (01): : 11 - 18
  • [24] Development of a new multi-residue laser diode thermal desorption atmospheric pressure chemical ionization tandem mass spectrometry method for the detection and quantification of pesticides and pharmaceuticals in wastewater samples
    Boisvert, Michel
    Fayad, Paul B.
    Sauve, Sebastien
    ANALYTICA CHIMICA ACTA, 2012, 754 : 75 - 82
  • [25] High-throughput cytochrome P450 inhibition assays using laser diode thermal desorption-atmospheric pressure chemical ionization-tandem mass spectrometry
    Wu, Jin
    Hughes, Christopher S.
    Picard, Pierre
    Letarte, Sylvain
    Gaudreault, Mireille
    Levesque, Jean-Francois
    Nicoll-Griffith, Deborah A.
    Bateman, Kevin P.
    ANALYTICAL CHEMISTRY, 2007, 79 (12) : 4657 - 4665
  • [26] Liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry method for the quantification of pregabalin in human plasma
    Nirogi, Ramakrishna
    Kandikere, Vishwottam
    Mudigonda, Koteshwara
    Komarneni, Prashanth
    Aleti, Raghupathi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (30): : 3899 - 3906
  • [27] Laser desorption-atmospheric pressure chemical ionization mass spectrometry for the analysis of peptides from aqueous solutions
    Coon, JJ
    Harrison, WW
    ANALYTICAL CHEMISTRY, 2002, 74 (21) : 5600 - 5605
  • [28] Atmospheric Pressure Laser-Induced Acoustic Desorption Chemical Ionization Mass Spectrometry for Analysis of Saturated Hydrocarbons
    Nyadong, Leonard
    Quinn, John P.
    Hsu, Chang S.
    Hendrickson, Christopher L.
    Rodgers, Ryan P.
    Marshall, Alan G.
    ANALYTICAL CHEMISTRY, 2012, 84 (16) : 7131 - 7137
  • [29] Quantitative analysis of triglycerides using atmospheric pressure chemical ionization mass spectrometry
    Byrdwell, WC
    Emken, EA
    Neff, WE
    Adlof, RO
    LIPIDS, 1996, 31 (09) : 919 - 935
  • [30] Atmospheric pressure laser desorption/chemical ionization mass spectrometry: a new ionization method based on existing themes
    Coon, JJ
    McHale, KJ
    Harrison, WW
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (07) : 681 - 685