The purpose of this study was to evaluate the usefulness and clinical applications of MultiVaneXD which was applying iterative motion correction reconstruction algorithm T2-weighted images compared with MultiVane images taken with a 3T MRI. A total of 20 patients with suspected pathologies of the liver and pancreatic-biliary system based on clinical and laboratory findings underwent upper abdominal MRI, acquired using the MultiVane and MultiVaneXD techniques. Two reviewers analyzed the MultiVane and MultiVaneXD T2-weighted images qualitatively and quantitatively. Each reviewer evaluated vessel conspicuity by observing motion artifacts and the sharpness of the portal vein, hepatic vein, and upper organs. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated by one reviewer for quantitative analysis. The interclass correlation coefficient was evaluated to measure inter-observer reliability. There were significant differences between MultiVane and MultiVaneXD in motion artifact evaluation. Furthermore, MultiVane was given a better score than MultiVaneXD in abdominal organ sharpness and vessel conspicuity, but the difference was insignificant. The reliability coefficient values were over 0.8 in every evaluation. MultiVaneXD (2.12) showed a higher value than did MultiVane (1.98), but the difference was insignificant (p = 0.135). MultiVaneXD is a motion correction method that is more advanced than MultiVane, and it produced an increased SNR, resulting in a greater ability to detect focal abdominal lesions.
引用
收藏
页码:238 / 243
页数:5
相关论文
共 50 条
  • [41] Primary biliary cirrhosis: Evaluation with T2-weighted MR imaging and MR cholangiopancreatography
    Haliloglu, Nuray
    Erden, Ayse
    Erden, Ilhan
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 69 (03) : 523 - 527
  • [42] Comparison of T2-Weighted 3D-Space and T2-Weighted 2D-TSE Sequences in Lumbar Spine MR Imaging
    Qurat-ul-Ain
    Nadeem, Syed Farrukh
    Mirza, Tariq Mahmood
    Shafiq, Mazhar
    Batool, Zahida
    Khadijah-tul-Kubra
    ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2023, 29 (04): : 361 - 366
  • [43] T2-weighted echo planar MR imaging of the abdomen - Optimization of imaging parameters
    Li, T
    Mirowitz, SA
    CLINICAL IMAGING, 2003, 27 (02) : 124 - 128
  • [44] Liver metastases: Preoperative evaluation with CTAP and ferumoxide-enhanced T1-weighted and T2-weighted imaging
    VandenHeuvel, AG
    VanderSijp, JR
    Kruijt, R
    Oudkerk, M
    RADIOLOGY, 1997, 205 : 972 - 972
  • [45] TEMPOROMANDIBULAR-JOINT DERANGEMENTS - MR FAST SCANNING COMPARED TO T1-WEIGHTED AND T2-WEIGHTED IMAGING TECHNIQUES
    SCHELLHAS, KP
    FRITTS, HM
    HEITHOFF, KB
    JAHN, JA
    WILKES, CH
    OMLIE, MR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (05) : 1021 - 1021
  • [46] Imaging cortical demyelination using T1/T2-weighted ratio
    Nakamura, K.
    Chen, J. T.
    Fox, R. J.
    Ontaneda, D.
    Trapp, B. D.
    MULTIPLE SCLEROSIS JOURNAL, 2016, 22 : 526 - 526
  • [47] A METHOD FOR REDUCING MOTION INDUCED ERRORS IN T2-WEIGHTED MAGNETIC-RESONANCE-IMAGING
    JOSEPH, PM
    SHETTY, A
    BONAROTI, EA
    MEDICAL PHYSICS, 1987, 14 (04) : 608 - 615
  • [48] T2-weighted Lung Imaging Using a 0.55-T MRI System
    Campbell-Washburn, Adrienne E.
    Malayeri, Ashkan A.
    Jones, Elizabeth C.
    Moss, Joel
    Fennelly, Kevin P.
    Olivier, Kenneth N.
    Chen, Marcus Y.
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2021, 3 (03):
  • [49] T2-weighted prostate imaging using echo-planar imaging at 3T
    Ragan, D
    Ma, J
    MEDICAL PHYSICS, 2005, 32 (06) : 1911 - 1911
  • [50] T2*-weighted Image/T2-weighted Image Fusion in Postimplant Dosimetry of Prostate Brachytherapy
    Katayama, Norihisa
    Takemoto, Mitsuhiro
    Yoshio, Kotaro
    Katsui, Kuniaki
    Uesugi, Tatsuya
    Nasu, Yasutomo
    Matsushita, Toshi
    Kaji, Mitsumasa
    Kumon, Hiromi
    Kanazawa, Susumu
    JOURNAL OF RADIATION RESEARCH, 2011, 52 (05) : 680 - 684