Mechanical, Electrochemical and Biological Behavior of 3D Printed-Porous Titanium for Biomedical Applications

被引:0
|
作者
Morris D. [1 ]
Mamidi S.K. [1 ]
Kamat S. [1 ]
Cheng K.-Y. [1 ]
Bijukumar D. [1 ]
Tsai P.-I. [2 ]
Wu M.-H. [3 ,4 ]
Orías A.A.E. [5 ]
Mathew M.T. [1 ,5 ,6 ]
机构
[1] Department of Biomedical Science, The University of Illinois College of Medicine, Rockford, IL
[2] Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Hsinchu
[3] Department of Orthopedics, Taipei Medical University Hospital, Taipei
[4] Department of Orthopedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei
[5] Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
[6] Restorative Dentistry, University of Illinois At Chicago, Chicago, IL
关键词
3D printing; Additive manufacturing; Porosity; Titanium;
D O I
10.1007/s40735-020-00457-5
中图分类号
学科分类号
摘要
Porosity is a feature that can be designed into 3D printed parts, notably surgical implants, and porosity is associated with improved biocompatibility and osseointegration. It is imperative to evaluate the electrochemical behavior of 3D printed-porous Ti to identify the optimum porosity with low corrosion kinetics for biomedical applications. The objective of this study was to evaluate the corrosion kinetics, mechanical properties, and biocompatibility of 3D printed porous Titanium alloy metal. 3D printed porous Ti samples of 11 mm diameter and 7 mm thick with five porosity levels (0%, 20%, 40%, 60%, and 80%) were manufactured, mechanically tested, studied for characterization and Electrochemical behavior. The cell proliferations was also conducted on different groups for the examination of their biocompatibility, which might indicate the influence of porosity to the cellular activities. The results showed that increasing porosity corresponds with decreasing mechanical strength and increasing corrosion characteristics. Corrosion current, Icorr values ranged from 10−7 to 10−4 A, and Ecorr values ranged from + 100 to − 600 mV for all five porosity-level samples. Analysis of EIS data indicated that capacitance values ranged from 0.00025 to 0.0015F. In addition, sample porosity showed evidence of other corrosion forms such as crevice corrosion and intergranular corrosion. The results of cell proliferations demonstrated all groups of specimens are biocompatible and the ones with 0% and 40% porosity exhibited the highest increments of cells, implying their potential in biomedical application. The study revealed that 3D printed Ti samples with larger porosity were subjected to increased electrochemical corrosion. A porosity between 40 and 60% 3D printed porous Ti study sample was found optimum for the biomedical application. The development of future biomedical devices will have to maintain a balanced approach between the osseointegration of large porosities and increased corrosion tendencies to optimize safer devices through additive manufacturing or 3D printing for better patient outcomes. Further studies will evaluate 3D-printed tribocorrosion properties and biocompatibility via osteoblast culture. © 2021, The Author(s), under exclusive licence to Springer Nature Switzerland AG part of Springer Nature.
引用
收藏
相关论文
共 50 条
  • [41] Preliminary Evaluation of 3D Printed Chitosan/Pectin Constructs for Biomedical Applications
    Michailidou, Georgia
    Terzopoulou, Zoe
    Kehagia, Argyroula
    Michopoulou, Anna
    Bikiaris, Dimitrios N.
    MARINE DRUGS, 2021, 19 (01)
  • [42] 3D printed PLA/copper bowtie antenna for biomedical imaging applications
    Avsar Aydin, Emine
    Torun, Ahmet Refah
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (04) : 1183 - 1193
  • [43] Electrochemical and biological behaviour of near β Titanium alloy for biomedical implant applications
    Gnanavel, S.
    Ponnusamy, S.
    Sivakumar, Kirthana
    Priyadarshini, D.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART J-JOURNAL OF ENGINEERING TRIBOLOGY, 2022, 236 (02) : 233 - 241
  • [44] 3D Printed Electrochemical Sensors
    Abdalla, Aya
    Patel, Bhavik Anil
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 14, 2021, 2021, 14 : 47 - 63
  • [45] Influence of 3D printed porous aluminum anode structure on electrochemical performance
    Han, Jitai
    Zhu, Kui
    Li, Peng
    Li, Yin
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2025, 142 : 570 - 581
  • [46] Mechanical behaviour of 3D printed fiber-reinforced soft functional hydrogel composite: Opportunities for biomedical applications
    Goyal, Rohit
    Mitra, Santanu
    MATERIALS TODAY COMMUNICATIONS, 2025, 42
  • [47] Mechanophysical and biological properties of a 3D-printed titanium alloy for dental applications
    Kim, Jae-Heon
    Kim, Moon-Young
    Knowles, Jonathan C.
    Choi, Sunyoung
    Kang, Hyejong
    Park, Sang-hyun
    Park, Sung-Min
    Kim, Hae-Won
    Park, Jong-Tae
    Lee, Jung-Hwan
    Lee, Hae-Hyoung
    DENTAL MATERIALS, 2020, 36 (07) : 945 - 958
  • [48] 3D-printed microneedles in biomedical applications
    Dabbagh, Sajjad Rahmani
    Sarabi, Misagh Rezapour
    Rahbarghazi, Reza
    Sokullu, Emel
    Yetisen, Ali K.
    Tasoglu, Savas
    ISCIENCE, 2021, 24 (01)
  • [49] 3D-printed polymers for biomedical applications
    Seppala, J.
    EXPRESS POLYMER LETTERS, 2016, 10 (10): : 788 - 788
  • [50] 3D-printed electronics for biomedical applications
    Ryoo, Minsu
    Kim, Daeho
    Noh, Junseop
    Ahn, Song Ih
    INTERNATIONAL JOURNAL OF BIOPRINTING, 2024, 10 (06)