Mechanical, Electrochemical and Biological Behavior of 3D Printed-Porous Titanium for Biomedical Applications

被引:0
|
作者
Morris D. [1 ]
Mamidi S.K. [1 ]
Kamat S. [1 ]
Cheng K.-Y. [1 ]
Bijukumar D. [1 ]
Tsai P.-I. [2 ]
Wu M.-H. [3 ,4 ]
Orías A.A.E. [5 ]
Mathew M.T. [1 ,5 ,6 ]
机构
[1] Department of Biomedical Science, The University of Illinois College of Medicine, Rockford, IL
[2] Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Hsinchu
[3] Department of Orthopedics, Taipei Medical University Hospital, Taipei
[4] Department of Orthopedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei
[5] Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
[6] Restorative Dentistry, University of Illinois At Chicago, Chicago, IL
关键词
3D printing; Additive manufacturing; Porosity; Titanium;
D O I
10.1007/s40735-020-00457-5
中图分类号
学科分类号
摘要
Porosity is a feature that can be designed into 3D printed parts, notably surgical implants, and porosity is associated with improved biocompatibility and osseointegration. It is imperative to evaluate the electrochemical behavior of 3D printed-porous Ti to identify the optimum porosity with low corrosion kinetics for biomedical applications. The objective of this study was to evaluate the corrosion kinetics, mechanical properties, and biocompatibility of 3D printed porous Titanium alloy metal. 3D printed porous Ti samples of 11 mm diameter and 7 mm thick with five porosity levels (0%, 20%, 40%, 60%, and 80%) were manufactured, mechanically tested, studied for characterization and Electrochemical behavior. The cell proliferations was also conducted on different groups for the examination of their biocompatibility, which might indicate the influence of porosity to the cellular activities. The results showed that increasing porosity corresponds with decreasing mechanical strength and increasing corrosion characteristics. Corrosion current, Icorr values ranged from 10−7 to 10−4 A, and Ecorr values ranged from + 100 to − 600 mV for all five porosity-level samples. Analysis of EIS data indicated that capacitance values ranged from 0.00025 to 0.0015F. In addition, sample porosity showed evidence of other corrosion forms such as crevice corrosion and intergranular corrosion. The results of cell proliferations demonstrated all groups of specimens are biocompatible and the ones with 0% and 40% porosity exhibited the highest increments of cells, implying their potential in biomedical application. The study revealed that 3D printed Ti samples with larger porosity were subjected to increased electrochemical corrosion. A porosity between 40 and 60% 3D printed porous Ti study sample was found optimum for the biomedical application. The development of future biomedical devices will have to maintain a balanced approach between the osseointegration of large porosities and increased corrosion tendencies to optimize safer devices through additive manufacturing or 3D printing for better patient outcomes. Further studies will evaluate 3D-printed tribocorrosion properties and biocompatibility via osteoblast culture. © 2021, The Author(s), under exclusive licence to Springer Nature Switzerland AG part of Springer Nature.
引用
收藏
相关论文
共 50 条
  • [21] Interfacial mechanical behavior of 3D printed ABS
    Cole, Daniel P. (daniel.p.cole.ctr@mail.mil), 1600, John Wiley and Sons Inc (133):
  • [22] Immunomodulation of surface biofunctionalized 3D printed porous titanium implants
    Razzi, F.
    Fratila-Apachitei, L. E.
    Fahy, N.
    Bastiaansen-Jenniskens, Y. M.
    Apachitei, I
    Farrell, E.
    Zadpoor, A. A.
    BIOMEDICAL MATERIALS, 2020, 15 (03)
  • [23] 3D PRINTED POROUS DIELECTRIC SUBSTRATES FOR RF APPLICATIONS
    SnigdhaTummala, Vana
    Mian, Ahsan
    Chamok, Nowrin H.
    Ali, Mohammod
    Clifford, Jallisa
    Majumdar, Prasun
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2016, VOL. 10, 2017,
  • [24] 3D printed soft and porous materials for functional applications
    Siqueira, Gilberto
    Hausmman, Michael
    Nagel, Yannick
    Zimmermann, Tanja
    Nystrom, Gustav
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [25] Recent progress in 3D printed piezoelectric materials for biomedical applications
    Hamza, Muhammad
    Kanwal, Qudsia
    Hussain, Muhammad Irfan
    Khan, Karim
    Asghar, Ali
    Liu, Zhiyuan
    Liu, Changyong
    Chen, Zhangwei
    MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2025, 164
  • [26] 3D printed tissue models: From hydrogels to biomedical applications
    Cadamuro, Francesca
    Nicotra, Francesco
    Russo, Laura
    JOURNAL OF CONTROLLED RELEASE, 2023, 354 : 726 - 745
  • [27] Interface contact behavior of 3D printed porous surfaces
    Heimbrook, Amanda
    Kelly, Cambre
    Gall, Ken
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2022, 21 : 4115 - 4126
  • [28] Research Progress on the Mechanical Properties of the Biomedical Titanium Alloy Porous Structures Fabricated by 3D Printing Technique
    Li Shujun
    Hou Wentao
    Hao Yulin
    Yang Rui
    ACTA METALLURGICA SINICA, 2023, 59 (04) : 478 - 488
  • [29] Effects of sintering temperature on morphology and mechanical characteristics of 3D printed porous titanium used as dental implant
    Gagg, Graham
    Ghassemieh, Elaheh
    Wiria, Florencia Edith
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (07): : 3858 - 3864
  • [30] Bacterial behavior on coated porous titanium substrates for biomedical applications
    Dominguez-Trujillo, Cristina
    Beltran, Ana M.
    Garvi, Maria D.
    Salazar-Moya, Alba
    Lebrato, Julian
    Hickey, Daniel J.
    Rodriguez-Ortiz, Jose A.
    Kamm, Paul H.
    Lebrato, Clara
    Garcia-Moreno, Francisco
    Webster, Thomas J.
    Torres, Yadir
    SURFACE & COATINGS TECHNOLOGY, 2019, 357 : 896 - 902