Development of a beam stop array system with dual scan mode for scatter correction of cone-beam CT

被引:0
|
作者
So Hyun Ahn
Jinho Choi
Kyu Chan Lee
Siyong Kim
Rena Lee
机构
[1] Gachon University Gil Hospital,Department of Radiation Oncology
[2] Ewha Womans University,Department of Medical Science
[3] Gachon University Gil Hospital,Department of Radiation Oncology
[4] Virginia Commonwealth University,Department of Radiation Oncology
[5] Ewha Womans University,Department of Radiation Oncology, School of Medicine
来源
关键词
Cone-beam CT; Scattered X-ray; Image quality; Beam stop array; Monte Carlo simulation;
D O I
暂无
中图分类号
学科分类号
摘要
A beam stop array (BSA) is widely used to estimate the scatter distribution of cone-beam computed tomography (CT) experimentally. A rectangular BSA, which is the most generally used, produces a penumbra region at the edge of the grid on the projection image. The penumbra region can be the cause of an inaccurate scatter estimate and loss of image data. In this study, two types of BSAs have been designed and developed, a linear BSA (l-BSA), which is a simple rectangular type, and a curved BSA (c-BSA) to avoid the penumbra effect. A Monte Carlo simulation was performed to determine the thickness and the material of beam stop arrays. The particle tracking technique of MCNP5 code was used to analyze the accuracy of the scatter distribution acquired by the beam stop arrays. The improvement in the image quality was analyzed by using an in-house phantom, a simple type CT phantom, and a humanoid phantom. How the curved beam stop array improved the penumbra effect was also analyzed in a large field of view. The additional dose caused by a dual scan was analyzed by using a Monte Carlo simulation and experiment. The accuracies of the scatter estimates were 83.4% for the c-BSA and 90.4% for the l-BSA. The c-BSA compensated the penumbra effect effectively while the l-BSA had a severe penumbra region in the partial projection image in a large field of view. Contrasts were improved by 24.8 (air-PMMA), 55.8 (Teflon-PMMA), and 81.7% (water-PMMA) for the c-BSA and 11.1 (air-PMMA), 44.1 (Teflon-PMMA), and 82.2% (water-PMMA) for the l-BSA by scatter correction. After noise suppression, the contrast-to-noise ratios were improved by 2.7–4.1 times for the c-BSA and 3.5–5.3 times for the l-BSA. Uniformities were also improved by up to 10 times for the c-BSA and 12 times for the l-BSA. The quality of the humanoid phantom image was also improved after the scatter correction. Consequently, the c-BSA can improve the image quality of cone-beam CT and compensate for the penumbra effect without an additional dose of radiation.
引用
下载
收藏
页码:1220 / 1229
页数:9
相关论文
共 50 条
  • [41] Feasibility of improving cone-beam CT number consistency using a scatter correction algorithm
    Li, Jun
    Yao, Weiguang
    Xiao, Ying
    Yu, Yan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (06): : 167 - 176
  • [42] Local filtration based scatter correction for cone-beam CT using primary modulation
    Zhu, Lei
    MEDICAL PHYSICS, 2016, 43 (11) : 6199 - 6209
  • [43] EXPERIMENTAL SCATTER CORRECTION METHODS IN INDUSTRIAL X-RAY CONE-BEAM CT
    Schoerner, K.
    Goldammer, M.
    Stephan, J.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 30A AND 30B, 2011, 1335 : 485 - 492
  • [44] Influence of Data Completion on Scatter Artifact Correction for Truncated Cone-Beam CT Data
    Waltrich, Nadine
    Sawall, Stefan
    Maier, Joscha
    Kuntz, Jan
    Stannigel, Kai
    Lindenberg, Kai
    Kachelriess, Marc
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [45] Scatter correction for flat detector cone-beam CT based on simulated sphere models
    Bertram, M.
    Hohmann, S.
    Wiegert, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2342 - 2343
  • [46] Beam hardening correction for a cone-beam CT system and its effect on spatial resolution
    赵维
    付国涛
    孙翠丽
    王燕芳
    魏存峰
    曹大泉
    阙介民
    唐晓
    史戒坚
    魏龙
    郁忠强
    Chinese Physics C, 2011, (10) : 978 - 985
  • [47] Beam hardening correction for a cone-beam CT system and its effect on spatial resolution
    Zhao Wei
    Fu Guo-Tao
    Sun Cui-Li
    Wang Yan-Fang
    Wei Cun-Feng
    Cao Da-Quan
    Que Jie-Min
    Tang Xiao
    Shi Rong-Jian
    Wei Long
    Yu Zhong-Qiang
    CHINESE PHYSICS C, 2011, 35 (10) : 978 - 985
  • [48] A PRACTICAL METHOD FOR SCATTER CORRECTION IN CONE BEAM CT
    Ploeger, L.
    Sonke, J. J.
    van Herk, M.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S129 - S129
  • [49] Model based scatter correction for cone-beam computed tomography
    Wiegert, J
    Bertram, M
    Rose, G
    Aach, T
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 271 - 282
  • [50] A Novel Scatter Correction Method for Cone-Beam Computed Tomography
    Zhou, Kun
    Tian, Jian
    Meng, Xiangxi
    Yang, Kun
    Xu, Baixuan
    Yang, Zhi
    Ren, Qiushi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (04) : 632 - 638