Surface analysis of softened paper by time-of-flight secondary ion mass spectrometry (ToF-SIMS) and the Kawabata evaluation system

被引:0
|
作者
M. Parfitt
J. C. Vickerman
R. Mitchell
C. M. Carr
N. Ince
P. Knight
机构
[1] UMIST,Department of Chemistry
[2] CSMA Ltd.,Department of Textiles
[3] UMIST,undefined
[4] Hercules Ltd.,undefined
来源
关键词
Mass Spectrometry; Objective Measurement; Evaluation System; Surface Chemical; Surface Analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Smoothness is an important factor in consumer perception of tissue quality, with physical modification and chemical additions to the paper able to enhance tissue handle. Therefore objective measurement of the papers mechanical properties in developing new products and maintaining existing quality is vital. In this study the surface chemical composition of the softener treated paper is investigated using ToF-SIMS, and related to the surface frictional properties of the paper.
引用
收藏
页码:2171 / 2177
页数:6
相关论文
共 50 条
  • [31] THE APPLICATION OF TIME-OF-FLIGHT SECONDARY ION MASS SPECTROMETRY (ToF-SIMS) TO THE CHARACTERIZATION OF OPAQUE ANCIENT GLASSES*
    Rutten, F. J. M.
    Briggs, D.
    Henderson, J.
    Roe, M. J.
    ARCHAEOMETRY, 2009, 51 : 966 - 986
  • [32] Analysis of Ink/Coating penetration on paper surfaces by time-of-flight secondary ion mass spectrometry (ToF-SIMS) in conjunction with principal component analysis (PCA)
    Sodhi, R. N. S.
    Sun, L.
    Sain, M.
    Farnood, R.
    JOURNAL OF ADHESION, 2008, 84 (03): : 277 - 292
  • [33] Time of flight secondary ion mass spectrometry (ToF-SIMS) use in sedimentary geochemistry
    Golledge, S
    Krinsley, D
    O'Hara, P
    Gasser, R
    Schieber, J
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2005, 69 (10) : A379 - A379
  • [34] Molecular weight effects on polystyrene fingerprint time-of-flight secondary ion mass spectrometry (ToF-SIMS) spectra
    Eynde, XV
    Bertrand, P
    Jerome, R
    MACROMOLECULES, 1997, 30 (21) : 6407 - 6416
  • [35] Removal of surface contaminants from wood polymer composites (WPCs) for analysis using time-of-flight secondary ion mass spectrometry (ToF-SIMS)
    Brunelle, Laura
    Gernold, Zacheriah
    Swagler, Christopher
    Welton, Emilee
    Michienzi, Matthew
    Goacher, Robyn
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [36] Superhydrophilization of Si Surface by Atmospheric-Pressure Plasma Jet Irradiation: Analysis by Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS)
    Kuwahata, Hiroshi
    Haraki, Takeshi
    Mikami, Ikko
    E-JOURNAL OF SURFACE SCIENCE AND NANOTECHNOLOGY, 2013, 11 : 36 - 39
  • [37] Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS): A New Tool for the Analysis of Toxicological Effects on Single Cell Level
    Jungnickel, Harald
    Laux, Peter
    Luch, Andreas
    TOXICS, 2016, 4 (01)
  • [38] Imaging and quantitative analysis of insecticide in mosquito net fibers using Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS)
    Smith, Stephen C.
    Zhou, Chuanzhen
    Stevie, Fred A.
    Garcia, Roberto
    PLOS ONE, 2018, 13 (12):
  • [39] Time-of-flight secondary ion mass spectrometry (TOF-SIMS) analysis of the Orgueil CI meteorite at high lateral resolution.
    Stephan, T
    Rost, D
    Jessberger, EK
    Klock, W
    METEORITICS & PLANETARY SCIENCE, 1997, 32 (04): : A124 - A125
  • [40] Characterisation of the bound lipids at the wool fibre surface by time of flight secondary ion mass spectrometry (ToF-SIMS)
    Rankin, D. A.
    Carr, C. M.
    JOURNAL OF THE TEXTILE INSTITUTE, 2013, 104 (02) : 197 - 212