Hydrogen Ion-Selective Poly(vinyl chloride) Membrane Electrode Based on a Calix[4]arene

被引:0
|
作者
Demet Kuruoğlu
Esin Canel
Shahabuddin Memon
Mustafa Yilmaz
Esma Kiliç
机构
[1] Ankara University,Department of Chemistry, Faculty of Science
[2] Selçuk University,Department of Chemistry
来源
Analytical Sciences | 2003年 / 19卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A hydrogen ion-selective poly(vinyl chloride) membrane electrode was constructed using 5,11,17,23-tetra-tert-butyl-25,26,27,28-tetracyanomethoxycalix[4]arene as a neutral carrier. The electrode showed an apparent Nernstian response in the 2 - 11.5 pH range with a slope of 54.0±0.2 mV/pH at 20±1°C. This electrode showed a rapid response of the emf to changes in the pH, high ion selectivity with respect to lithium, sodium and potassium, and characteristics similar to those reported for the conventional pH glass membrane electrode. It can be used as a potentiometric indicator electrode in hydrofluoric acid solutions. The effects of iodide, thiocyanate, perchlorate and bromide on the characteristics of the electrode were also considered.
引用
收藏
页码:217 / 221
页数:4
相关论文
共 50 条
  • [21] SULFATE ION-SELECTIVE ELECTRODE BASED ON POLY(VINLY CHLORIDE) MEMBRANE CONTAINING BARIUM CHLORANILATE
    KOJIMA, T
    OKUNO, S
    SHIGETOMI, Y
    BUNSEKI KAGAKU, 1992, 41 (01) : 63 - 64
  • [22] A chloride ion-selective solvent polymeric membrane electrode based on a hydrogen bond forming ionophore
    Xiao, KP
    Buhlmann, P
    Nishizawa, S
    Amemiya, S
    Umezawa, Y
    ANALYTICAL CHEMISTRY, 1997, 69 (06) : 1038 - 1044
  • [23] Novel monohydrogenphosphate ion-selective polymeric membrane sensor based on phenyl urea substituted calix[4]arene
    Modi, Nishith R.
    Patel, Bhargav
    Patel, Manishkumar B.
    Menon, Shobhana K.
    TALANTA, 2011, 86 : 121 - 127
  • [24] Lead ion selective electrode based on novel calix[4]arene derivative
    Ju, HF
    Chen, LX
    He, XW
    Zhao, BT
    Liu, Y
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (10) : 1121 - 1124
  • [25] ION-PAIRING AND ACID DISSOCIATION-CONSTANTS IN POLY(VINYL CHLORIDE)-BASED ION-SELECTIVE ELECTRODE MEMBRANES
    VERPOORTE, EMJ
    CHAN, ADC
    HARRISON, DJ
    ELECTROANALYSIS, 1993, 5 (9-10) : 845 - 854
  • [26] IMPEDANCE BEHAVIOR OF POLY (VINYL-CHLORIDE) MATRIX MEMBRANE ION-SELECTIVE ELECTRODES
    AHMADBITAR, R
    ABDULGADER, MM
    ZIHLIF, AM
    JABER, AMY
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 143 (1-2) : 121 - 133
  • [27] CHLORATE ION-SELECTIVE ELECTRODE BASED ON A POLYVINYL CHLORIDE MATRIX MEMBRANE
    HIIRO, K
    MOODY, GJ
    THOMAS, JDR
    TALANTA, 1975, 22 (10-1) : 918 - 919
  • [28] Characterization of Chromogenic Calix[4]arene Derivative Based Ion-Selective Optical Sensors
    Bui Thi Thu Lan
    Klára Tóth
    Analytical Sciences, 1998, 14 : 191 - 197
  • [29] A POTASSIUM-ION SELECTIVE ELECTRODE WITH VALINOMYCIN BASED POLY(VINYL CHLORIDE) MEMBRANE AND A POLY(VINYL FERROCENE) SOLID CONTACT
    HAUSER, PC
    CHIANG, DWL
    WRIGHT, GA
    ANALYTICA CHIMICA ACTA, 1995, 302 (2-3) : 241 - 248
  • [30] Silver ion-selective electrodes based on novel containing benzothiazolyl calix[4]arene
    Chen, LX
    Ju, HF
    Zeng, XS
    He, XW
    Zhang, ZZ
    ANALYTICA CHIMICA ACTA, 2001, 437 (02) : 191 - 197