Detection of the human prostate-specific antigen using an aptasensor with gold nanoparticles encapsulated by graphitized mesoporous carbon

被引:0
|
作者
Bei Liu
Lingsong Lu
Erhui Hua
Shuting Jiang
Guoming Xie
机构
[1] Chongqing Medical University,Key Laboratory of Medical Diagnostics of Ministry of Education, Department of Laboratory Medicine
来源
Microchimica Acta | 2012年 / 178卷
关键词
Prostate specific antigen; Aptamer·Graphitized mesoporous carbon; Gold nanoparticle;
D O I
暂无
中图分类号
学科分类号
摘要
We report on a sensitive electrochemical aptasensor for the detection of human prostate specific antigen (PSA). It is based on the signal amplification of the biotin-avidin system using a sensing platform that is making use of a graphite electrode modified with gold nanoparticles that were covered with graphitized mesoporous carbon nanoparticles (AuNPs@GMCs). The AuNPs@GMCs hybrid was prepared by linking 1,6-hexanedithiol-functionalized GMCs and gold nanoparticles via Au-S groups. Then, streptavidin was immobilized on the electrode modified with the AuNPs@GMCs so to enlarge the amount of biotin-aptamer which led to enhanced detection sensitivity. If an PSA aptamer captures the target PSA on the electrode, the differential pulse voltammetric (DPV) signal of the hexacyanoferrate redox system decreases. Factors affecting the performance of the aptasensor were studied in detail. Under optimal conditions, the DPV signal changes could be used to quantitatively detect PSA in the concentration range from 0.25 to 200 ng mL−1, with a lowest limit of detection as small as 0.25 ng mL−1. The aptasensor is highly specific and displays acceptable precision, good stability and repeatability.
引用
收藏
页码:163 / 170
页数:7
相关论文
共 50 条
  • [41] Prostate-specific antigen and prostate cancer: prediction, detection and monitoring
    Hans Lilja
    David Ulmert
    Andrew J. Vickers
    Nature Reviews Cancer, 2008, 8 : 268 - 278
  • [42] Early detection of prostate cancer - Role of prostate-specific antigen
    Prabhakaran, VM
    CANADIAN FAMILY PHYSICIAN, 1996, 42 : 709 - 712
  • [43] The role of free prostate-specific antigen in prostate cancer detection
    Han M.
    Potter S.R.
    Partin A.W.
    Current Urology Reports, 2000, 1 (1) : 78 - 82
  • [44] Chemiluminescent aptasensor capable of rapidly sensing prostate-specific antigen in human serum using a dual-aptamer and paramagnetic bead
    Kim, Kyungeun
    Kim, Min Jae
    Park, Prestan
    Lee, Ji
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [45] Highly Sensitive Immunofluorescence Assay of Prostate-Specific Antigen Using Silver Nanoparticles
    Koktysh, I. V.
    Melnikova, Ya. I.
    Kulakovich, O. S.
    Ramanenka, A. A.
    Vaschenko, S. V.
    Muravitskaya, A. O.
    Gaponenko, S. V.
    Maskevich, S. A.
    JOURNAL OF APPLIED SPECTROSCOPY, 2020, 87 (05) : 870 - 876
  • [46] Highly Sensitive Immunofluorescence Assay of Prostate-Specific Antigen Using Silver Nanoparticles
    I. V. Koktysh
    Ya. I. Melnikova
    O. S. Kulakovich
    A. A. Ramanenka
    S. V. Vaschenko
    A. O. Muravitskaya
    S. V. Gaponenko
    S. A. Maskevich
    Journal of Applied Spectroscopy, 2020, 87 : 870 - 876
  • [47] Ultrasensitive detection of prostate-specific antigen using glucose-encapsulated nanoliposomes anti-PSA polyclonal antibody as detection nanobioprobes
    Mwanza, Daniel
    Mfamela, Nololo
    Adeniyi, Omotayo
    Nyokong, Tebello
    Mashazi, Philani
    TALANTA, 2022, 245
  • [48] Immunosensing of prostate cancer in human plasma samples using immobilization of antibody on the surface of mesoporous silica-modified silver nanoparticles and its immunocomplex with prostate-specific antigen
    Farshchi, Fatemeh
    Hasanzadeh, Mohammad
    Solhi, Elham
    ANALYTICAL METHODS, 2019, 11 (48) : 6159 - 6167
  • [49] Europium nanoparticles and time-resolved fluorescence for ultrasensitive detection of prostate-specific antigen
    Härmä, H
    Soukka, T
    Lövgren, T
    CLINICAL CHEMISTRY, 2001, 47 (03) : 561 - 568
  • [50] Different free prostate-specific antigen to total prostate-specific antigen ratios using three detecting systems
    Huang, Hui-Qing
    Zhang, Yan
    Xu, Hua-Guo