Polyaniline based catalase biosensor for the detection of hydrogen peroxide and azide

被引:0
|
作者
Ravindra P. Singh
Da-Yeon Kang
Byung-Keun Oh
Jeong-Woo Choi
机构
[1] Sogang University,Department of Chemical and Biomolecular Engineering
[2] Sogang University,Interdisciplinary Program of Integrated Biotechnology
关键词
Polyaniline (PANi); catalase (CAT); hydrogen peroxide (H; O; ); azide; biosensor; bioelectrode;
D O I
暂无
中图分类号
学科分类号
摘要
The CAT/PANi/ITO bioelectrode has been prepared as a catalase biosensor and shows response for monitoring not only of H2O2 but also azide. The sensor exhibited an excellent response to the H2O2 and azide. The linear range of H2O2 was 0.064∼1 mM and for azide 0.125∼4 mM, respectively. Catalase biosensor was based on the principle of the measurements as the decrease in the differentiation of oxygen level, which has been caused by the inhibition of catalase in the bioactive layer of the biosensor by azide. The repeatability experiments were done in triplicate. The logarithm response of the biosensor to H2O2 (r2 = 0.99), as well as, for azide (r2 = 0.90) were reported, respectively. The bioelectrode was characterized by CV and AFM. The proposed biosensor would be applied for the determination of H2O2 and azide in various biological samples.
引用
收藏
页码:443 / 449
页数:6
相关论文
共 50 条
  • [1] Polyaniline Based Catalase Biosensor for the Detection of Hydrogen Peroxide and Azide
    Singh, Ravindra P.
    Kang, Da-Yeon
    Oh, Byung-Keun
    Choi, Jeong-Woo
    BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2009, 14 (04) : 443 - 449
  • [2] A new polyaniline-catalase-glutaraldehyde-modified biosensor for hydrogen peroxide detection
    Akyilmaz, Erol
    Oyman, Gizem
    Cinar, Ezgi
    Odabas, Gorkem
    PREPARATIVE BIOCHEMISTRY & BIOTECHNOLOGY, 2017, 47 (01): : 86 - 93
  • [3] A hydrogen peroxide biosensor based on polyaniline/FTO
    Wang, Peng
    Li, Shengqi
    Kan, Jinqing
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 137 (02) : 662 - 668
  • [4] THE REACTION BETWEEN CATALASE, AZIDE AND HYDROGEN PEROXIDE
    THEORELL, H
    EHRENBERG, A
    ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1952, 41 (02) : 462 - 474
  • [5] Catalase based hydrogen peroxide biosensor for mercury determination by inhibition measurements
    Elsebai, Basant
    Ghica, Mariana Emilia
    Abbas, Mohammed Nooredeen
    Brett, Christopher M. A.
    JOURNAL OF HAZARDOUS MATERIALS, 2017, 340 : 344 - 350
  • [6] Amperometric biosensor for the detection of hydrogen peroxide using catalase modified electrodes in polyacrylamide
    Varma, S
    Mattiasson, B
    JOURNAL OF BIOTECHNOLOGY, 2005, 119 (02) : 172 - 180
  • [7] BIOSENSOR FOR DETERMINATION OF HYDROGEN-PEROXIDE BASED ON CATALASE ACTIVITY OF HUMAN ERYTHROCYTES
    RACEK, J
    PETR, R
    ANALYTICA CHIMICA ACTA, 1990, 239 (01) : 19 - 22
  • [8] Development and characterization in vitro of a catalase-based biosensor for hydrogen peroxide monitoring
    O'Brien, K. B.
    Killoran, S. J.
    O'Neill, R. D.
    Lowry, J. P.
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (12): : 2994 - 3000
  • [9] CATALASE BIOSENSOR FOR THE DETERMINATION OF HYDROGEN-PEROXIDE, FLUORIDE AND CYANIDE
    STEIN, K
    HAIN, JU
    MIKROCHIMICA ACTA, 1995, 118 (1-2) : 93 - 101
  • [10] A rapid method for detection of catalase-positive and catalase-negative bacteria based on monitoring of hydrogen peroxide evolution at a composite peroxidase biosensor
    Serra, B.
    Zhang, J.
    Morales, M. D.
    Guzman-Vazquez de Prada, A.
    Reviejo, A. J.
    Pingarron, J. M.
    TALANTA, 2008, 75 (04) : 1134 - 1139